Loading...
Park West CC(02)-LR 960830GEOTECHNICAL AND ~ ~ r'l Ii p ENVIRONMENTAL CONSULTANTS REPORT OF FIELD DENSITY TESTS Parkwest Center - Building I Airline Drive Coppell, Texas REPORTED TO: Insignia Commedcal Group, Inc. 7557 Rambler Road, Suite 1300 Dallas, Texas 75231-7167 ATTN: Mr. Brian E. Grant REPORT NO. 9 REPORT DATE: 08-30-96 REG PROJECT NO. 2753.2 TECHNICIAN: B. Lucas CONTRACTOR: Bob Moore Construction, Inc. 1 D-698 Dark gray clay 20.8 92.3 2 D-698 Yellowish-brown clayey sand 14.7 111.4 3 D-698 Reddish-brown clayey sand 14.1 114.2 4 D-698 Light brown clayey sand 13.1 113.7 5 D-698 Dark gray & brown clay 26.4 94.4 110 08-12-96 Line ST-l/ 0.0 90.9 24.4 5 96.3 STA 6+75 111 Line ST-l/ 0.5 91.6 26.1 5 97.0 STA 6+50 112 125'N,300'E(1) 0.0 113.8 13.4 4 100.0 113 125'N,370'E(1) 0.0 111.5 14.5 4 98,1 114 125'N,200'E(1) 0.0 113.2 14.0 4 99.6 115 125'N, 75'E(1) 0.0 114.8 13.3 4 101.0 116 175'N, 70'E(1) 0.0 114.5 12.7 4 100.7 117 175'N, 190'E(1 ) 0.0 113.6 13.2 4 99.9 118 175'N,250'E(1) 0.0 112.1 14.1 4 98.6 119 220'N, 20'E(1) 0.0 113.1 13.1 4 99.5 120 220'N,200'E(1) 0.0 113.3 14.7 4 99.6 121 220'N,280'E(1) 0.0 112.8 14.4 4 99.2 122 08-13-96 225'N,380'E(1) 0.0 110.9 11.6 4 97.5 123 275'N,380'E(1) 0.0 110.7 12.2 4 97.4 124 325'N, 50'E(1 ) 0.7 106.7 15.0 4 93.8a 125 325'N,150'E(1) 0.7 104.7 15.3 4 92.0b 126 08-14-96 325'N, 50'E(1) 0.7 113.8 14.8 4 100.1A 127 325'N,150'E(1) 0.7 113.6 12.7 4 99.9B 128 325'N,275'E(1 ) 0.7 113.0 12.4 4 99.4 129 325'N,365'E(1) 0.7 112.7 12.2 4 99.1 130 425'N,100'E(1) 0.7 109.7 15.3 4 9(~.5 2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019 131 08-14-96 425'N,200'E(1) 0.7 113.3 13.9 4 99.6 132 425'N,280'E(1) 0.7 110.4 14.3 4 97.1 133 425'N,390'E(1) 0.7 110.4 12.7 4 97.1 134 370'N,340'E(1) 0.7 111.6 12.9 4 98.2 135 370'N,220'E(1) 0.7 112.4 14.0 4 98.9 136 370'N,120'E(1) 0.7 112.7 14.1 4 99.1 137 370'N, 60'E(1 ) 0.7 110.5 14.2 4 97.2 Comments: Where tested, materials were in compliance with project specifications, unless noted otherwise. Failing test noted in lower case letter, passing retest noted in corresponding upper case letter. Footnote: (1) Measurements referenced from S.W. building comer. Distribution: (1) Insignia Commerical Group, Inc./ Mr. Brian E. Grant (1) Hardy McCullah/MLM Architects/ Mr. Norman Coates (1) TenEyck*Merritt*Barnett*Pitt/ Mr. Frank Merritt (1) Bob Moore Construction, Inc./ Mr. Ed T. McGuire (1) City of CoppelI-Building Inspections/ Mr. Lee Stone ~)"City of Coppell/Mr. Larry Davis Submitted by: REED ENGINEERING GROUP, INC. Original Signed By Ronald F. Reed, P.E. RFR/msm