Loading...
Park West CC(1)-CS 900206PAAE 1 OF 2 DONALD E. DAVIS CONSULTING ENGINEERS 5506 COCKRELL HILL ROAD DALLAS, TEXAS 75236 (214) 337-2332 FEB. 6, 1~'~0 RO .... ELL D~YLE CITY ENGINEER CITY OF/COPPELL DEPT. ~= PUBLIC WORKS P.O. ~OX 478 732)F~EFOREST COP~ELL, TEXAS 7501~ RE: PAR[( WEST COMMERCE CENTER - FINAL PLAT C0190013. ARD THIS IS A REQUEST FOR A MEETING WITH YOU AND YOUR STAFF CONCERNING THE STUDY OF GRAPEVINE CREEK. THE F.E.M.A. LETTER OF AUGUST 18, 1987 OUTLINES THE LAST SUBMITTALS AND INDICATES THAT A CONDITIONAL LETTER OF MAP REVISION WAS APPROVED SUBdECT TO A NUMBER OF ITEMS BEING FURNISHED TO F.E.M.A.. WE ARE NOW WORKING IN COOPERATION WITH PAT ACKER, P.E. TO FURNISH THESE ITEMS. AT THIS TIME PAT IS ADDRESSING THE PROBLEM OF THE HIGH VELOCITIES IN THE CREEl( AND WILL FOLLOW THROUGH WITH ALL OF THE ITEMS REQUESTED BY F.E.M.A,. THIS WORK MUST PROCEED ALONG WITH THE PLAT WORK AND CONSTRUCTION WORK BECAUSE F.E.M.A. REQUIRES THAT THE STUDIES INCLUDE THE "AS-BUILT" DEVELOPMENT. AS FAR AS PARK WEST COMMERCE CENTER IS CONCERNED - THE WORK PREVIOUSLY DONE TO OBTAIN THE CONDITIONAL LETTER DEFINES THE FLOOD PLAIN AND WATER SURFACE THROUGH THE PROdECT. THE HIGH VELOCITIES MENTIONED DO NOT OCCUR DURING THE REACH THAT OCCURS WITHIN THE PROJECT. I UNDERSTAND THE NECESSITY OF CONTINUING AND COMPLETING THE STUDY BUT I REQUEST THAT OUR PLAT WORK BE ALLOWED TO CONTINIJE AS WAS DONE FOR THE PREVIOUS PLAT. ~ ~%f~l~ ~ ~,/~ THE SECOND SUBJECT TO BE DISCUSSED IN THE MEETING IS THE STORM WATER DESIGN CRITERIA TO BE USED IN THE SUBDIVISION. THE RAINFALL INTENSITY CURVES IN THE DOCUMENT CALLED FOR I~L~k~I~C~PELL SUBDIVISION ORDINANCE (TECH. PAPER 40) HAS BEEN FOUND TO BE~CORRECT~ THE METHOD USED TO DERIVE THE FINAL RAINFALL ~~-~O~ED I~THAT WERE NOT CORRECT. LATER WORK RESULTED IN ~'~EVISIONS BEING PUBLISHED IN THE FORM OF "HYDRO~[5" gY~CONSERVATION SERVICE. THIS REVISION HAS BEEN ADOF'TED BY THO"CITY OF DALL~ ALONG WITH OTHER MUNICIPALITIES. THE RAI]~IF-~-{~, INTENSITY~MINUTE TIME OF CONCENTRATION (100 YEAR RAIN) ~11.5 ~NCHES PER HOUR FRO~ T.P.40 WHEREAS TH~ INTENSITY FROM THE NEWER DATA ~S 6Sg//NCHES PER HOUR. i %~/, ~ i FEB. 67 1990 CO190013. ARD PAGE 2 OF 2 I HAVE WORKED ON A MAdOR PROdECT FOR THE CITY OF DALLAS RECENTLY AND THE 8.9 INCHES PER HOUR FIGURE WAS USED. ~-~-~q~T~ THE CITY OF COPPELL SUBDIVISION ORDINANCE ALLOWS A "~' VALUE FOR INDUSTRIAL AREAS OF FROM 0.7 TO 0.9. IN ORDER TO COMPLY WITH T~4E ORDINANCE AND ALSO BE REALISTIC ABOUT THE STORM WATER VOLUMES - I RECOMMEN/B THAT THE 11.5 INCHES PER HOUR FIGURE BE USED BUT THAT A "C" OF 0.7 BE USED.' THE RESULT IS PRACTICALLY THE SAME AS IF THE 8.9 INCHES PER HOUR WERE USED WITH A RUNOFF FACTOR OF DONALD E. DAVIS CONSULTING ENGINEERS CC: DON GERKEN LEE HANSEN MIKE TUCKER PAT ACKER