Park West CC(7)-CS 980714July 14, 1998 ENGINEERING, INC. City of Coppell 255 Parkway Boulevard Coppell, Texas 75019 Attn: Mr. Michael A. Martin Assistant City Engineer Re: Lakeview Center Wrangler and Belt Line Coppell, Texas Dear Mr. Martin: HBC Engineering, Inc. (HBC) provided the geotechnical investigation for the above referenced project and reported the results to Prentiss Properties in our report number 42-2112-97 in September, 1997. Based on that report the following minimum pavement sections are recommended. Automobile Parking Lots 5" of 3000 psi concrete on an unstabilized, compacted subgrade. Truck Areas (up to 20 daily repetitions) 6" of 4000 psi concrete on an unstabilized, compacted subgrade. For both sections the subgrade is to be uniformly compacted to a minimum of 95 percent of ASTM D 698 at -1 to +3 percent of the optimum moisture content determined by that test. Please contact us if there are any questions, or if we can provide additional information. Sincerely, HBC ENGINEERING, INC. RBB:ak cc: Davis Glass/Prentiss Properties Limited Houston Office 2313 W. Sam Houston Pkwy N; Suite 107 Houston, Texas 77043 (713) 722-0700 Fax (713) 722-0788 Dallas Office 8901 Carpenter Freeway, Suite 100 Dallas, Texas 75247 (214) 630-1010 Fax (214) 630-7070 Austin Office 3913 Todd Lane; Suite 312 Austin, Texas 78744 (512)442-1122 Fax (512) 442-1181 Atlanta Office 2470 Windy Hill Road; Suite 300 Marietta, Georgia 30067 (770) 618-3055 Fax (770) 618-3015