Loading...
Park West CC(7)-LR 981125CONCRETE COMPR 3SIVE STRENGTH Date of Service: 10/26/1998 Report No.: Client No.: 71765000 Project No.: Client: Prentiss Properties Limited, Inc. Project: Attn: DavidGlass 3860 W. Northwest Hwy. Dallas TX 75220 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 9829078 43-2170-98 Report Date 11/25/1998 Lakeview Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. SLUMP: AIR: TEST METHOD: CONTRACTOR: Butler Construction CONCRETE SUPPLIER: Pioneer PLANT: 22 SPECIFICATION REQUIREMENTS STRENGTH: 3000 psi ~ 28 Days 5-7" N/A ASTM C- 143 ASTM C- 172 ASTM C-39 PROJECT DATA CONCRETE CLASS: 9337 PLACEMENT DATE: 10/26/1998 BATCH TIME: 10:15am' TIME SAMPLED: 10:45am BY: Mike Shields WEATHER CONDITIONS: TEMPERATURE (F) - AIR TRUCKNO: 1883 AiR CONTENT (%): N/A PLACEMENT LOCATION: Sunny & clear 77 F CONCRETE: 80 F TICKET NO: 83274 UNIT WEIGHT (poD: N/A Piers- D/7.4, D/6.5, D/5.6, D/4.8, D/4, G.3/4 SAMPLE LOCATION: Pier D/6.5 CYLINDER MEASURED MARKED SLUMP SET NO. (inches) 1 1 5.75 REPORT OF TESTS DATE TESTED 11/02/1998 MAXIMUM AGE LOAD (days) (Ibs.~rce) 7 81050 ACCUMULATIVE YARDS: COMPRESSIVE STRENGTH (psi) 2870 10 FRACTURE TYPE I 2 5.75 1 3 5.75 Technician time: 11/23/1998 11/23/1998 See Report %9829077 28 126370 4470 28 119970 4240 Average 4360 Technician: Mike Shields Report Distribution: (1) Prentiss Properties Limited, Inc. (1) Alliance Architects, Inc. (1) Halff Associates (1) Mullen & Powell Technistructures, Started: Finished: (1) Butler Construction (1) City of Coppell (1) City of Coppell Vice President This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 0ILL Page I ofl CONCRETE COMPRI SIVE STRENGTH 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 10/27/1998 Report No.: Client No.: 71765000 Project No.: Client: Prentiss Properties Limited, Inc. Project: Attn: David Glass 3860 W. Northwest Hwy. Dallas TX 75220 9829178 43-2170-98 Lakeview Center Coppell, Texas Report Date 11/25/1998 Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. SLUMP: AIR: TEST METHOD: CONTRACTOR: Butler Construction CONCRETE SUPPLIER: Pioneer PLANT: 22 SPECIFICATION REQUIREMENTS STRENGTH: 40002 psi ~ 28 Days 3-5" N/A ASTM C-143 ASTM C- 172 ASTM C-39 SAMPLE LOCATION: Slab-on-grade G.5-3 CYLINDER MARKED SET NO. 1 1 6.50 1 2 6.50 I 3 6.5O 1 4 6.50 PROJECT DATA CONCRETE CLASS: 9349 PLACEMENT DATE: 10/27/1998 BATCH TIME: 5:00am TIME SAMPLED: 5:20am BY: Vince McManis WEATHER CONDITIONS: Cool/cloudy TEMPERATURE (F)-AIR 57 F CONCRETE: 74 F TRUCKNO: '1883 TICKETNO: 83324 AIR CONTENT (%): N/A UNIT WEIGHT (pcO: N/A PLACEMENT LOCATION: Slab-on-grade F to L, I to 10 REPORT OF TESTS ACCUMULATIVE YARDS: 60 MEASURED MAXIMUM COMPRESSIVE SLUMP DATE AGE LOAD STRENGTH FRACTURE (inches) TESTED (days) (lbs. force) (psi) TYPE 11/03/1998 7 112420 3980 11/03/1998 7 110630 3910 Average 3950 11/24/1998 28 141330 5000 11/24/1998 28 143960 5090 Average 5050 20 Gallons added to full load 0ILL This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. Page I of 8 ,CONCRETE COMPResSIVE STRENGTH 8901 Carpenter Frwy. Suite #100 Dallas, Texas 75247 Date of Service: Client No.: 10/27/1998 71765000 Report No.: 9829178 Project No.: 43-2170-98 Report Date 11/25/1998 Client: Prentiss Properties Limited, Inc. Project: Attn: David Glass 3860 W. Northwest Hwy. Dallas TX 75220 Lakeview Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. SLUMP: AIR: TEST METHOD: CONTRACTOR: Butler Construction CONCRETE SUPPLIER: Pioneer PLANT: 22 SPECIFICATION REQUIREMENTS STRENGTH: 40002 psi ~ 28 Days 3-5" N/A ASTM C- 143 ASTM C- 1 ?2 ASTM C-39 PROJECT DATA CONCRETE CLASS: 9349 PLACEMENT DATE: 10/27/1998 BATCH TIME: 5:39am TIME SAMPLED: 6:10am BY: Vince McManis WEATHER CONDITIONS: TEMPERATURE (F) - AIR TRUCK NO: 841 AIR CONTENT (%): N/A PLACEMENT LOCATION: See Page 1 Cool, cloudy 60 F CONCRETE: 72 F TICKET NO: 83333 UNIT WEIGHT (pcf): N/A SAMPLE LOCATION: 1.5-2.5 REPORT OF TESTS CYLINDER MEASURED MAXIMUM MARKED SLUMP DATE AGE LOAD SET NO. (inches) TESTED (days) (lbs. force) 2 1 6.50 11/03/1998 7 106590 2 2 6.50 11/03/1998 7 109690 Average 2 3 6.50 11/24/1998 28 135520 2 4 6.50 11/24/1998 28 135000 Average ACCUMULATIVE YARDS: 140 COMPRESSIVE STRENGTH (psi) 3770 3880 3830 4790 4770 4780 FRACTURE TYPE 0ILL This report is exclusively for the use of the client indicated above and shall not be reproduced except in tull without the written approval of HBC Engineering, Inc. Page 2 of 8 ,CONCRETE COMPResSIVE STRENGTH 8901 Carpenter Frwy. Suite #100 Dallas, Texas 75247 Date of Service: 10/27/1998 Client No.: 71765000 Report No.: 9829178 Project No.: 43-2170-98 Report Date 11/25/1998 Client: Prentiss Properties Limited, Inc. Attn: David Glass 3860 W. Northwest Hwy. Dallas TX 75220 Project: Lakeview Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. SLUMP: AIR: TEST METHOD: CONTRACTOR: Butler Construction CONCRETE SUPPLIER: Pioneer PLANT: 22 SPECIFICATION REQUIREMENTS STRENGTH: 40002 psi ~ 28 Days 3-5" N/A ASTM C-143 ASTM C- 172 ASTM C-39 PROJECT DATA CONCRETE CLASS: 9349 PLACEMENT DATE: 10/27/1998 BATCH TIME: 7:05am TIME SAMPLED: 7:35am aY: Vince McManis WEATHER CONDITIONS: Cool/cloudy TEMPERATURE (F)- AIR 63 F CONCRETE: 70 F TRUCK NO: 512 TICKET NO: 83352 AIR CONTENT.("/,,): N/A UNiT WEIGHT (pcf): N/A PLACEMENT LOCATION: See Page 1 SAMPLE LOCATION: K-3.5 REPORT OF TESTS ACCUMULATIVE YARDS: 270 CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH SET NO. (inches) TESTED (days) (lbs. force) (psi) 3 1 6.75 11/03/1998 7 102430 3620 3 2 6.75 11/03/1998 7 104710 3700 Average 3660 3 3 6.75 11/24/1998 28 129410 4580 3 4 6.75 11/24/1998 28 125370 4430 Average 4510 FRACTURE TYPE This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 01LL Page 3 of 8 'CONCRETE COMPRL SIVE STRENGTH TE[" 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 10/27/1998 Report No.: 9829178 Client No.: 71765000 Project No.: 43-2170-98 Client: Prentiss Properties Limited, Inc. Project:. Lakeview Center Attn: David Glass Coppell, Texas 3860 W. Northwest Hwy. Dallas TX 75220 Report Date 11/25/1998 Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. SLUMP: AIR: TEST METHOD: CONTRACTOR: Butler Construction CONCRETE SUPPLIER: Pioneer PLANT: 22 SPECIFICATION REQUIREMENTS STRENGTH: 40002 psi ~ 28 Days 3-5" N/A ASTM C-143 ASTM C- 172 ASTM C-39 PROJECT DATA CONCRETE CLASS: 9349 PLACEMENT DATE: 10/27/1998 BATCH TIME: 8:20am TIME SAMPLEO: 9:05am BY: Vince McManis WEATHER CONDITIONS: TEMPERATURE (F) - AIR TRUCK NO: 1883 AIR CONTENT (%): N/A PLACEMENT LOCATION: See Page I Cool, sunny 70 F CONCRETE: 74 F TIC~O~T NO: 83362 UNIT WEIGHT (pcl): N/A SAMPLE LOCATION: L-3.5 CYLINDER MARKED SET NO. 4 1 7.00 4 2 7.00 4 3 7.00 4 4 7.00 REPORT OF TESTS ACCUMULATIVE YARDS: 350 MEASURED MAXIMUM COMPRESSIVE SLUMP DATE AGE LOAD STRENGTH FRACTURE (inches) TESTED (days) (lbs. force) (psi) TYPE 11/03/1998 7 96400 3410 11/03/1998 7 92760 3280 Average 3350 11/24/1998 28 129920 4590 11/24/1998 28 127740 4520 Average 4560 20 Gallons of water added 0ILL This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. Page 4 of 8 -CONCRETE COMPRi. SIVE STRENGTH 8901 Carpenter Frwy, Suite #100 Dallas, Texas 75247 Date of Service: Client No.: 10/27/1998 71765000 Report No.: 9829178 P~:oject No.: 43-2170-98 Report Date 11/25/1998 Client: Prentiss Properties Limited, Inc. Project: Attn: David Glass 3860 W. Northwest Hwy. Dallas TX 75220 Lakeview Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. SLUMP: AIR: TEST METHOD: CONTRACTOR: Butler Construction CONCRETE SUPPLIER: Pioneer PLANT: 22 SPECIFICATION REQUIREMENTS STRENGTH: 40002 psi ~ 28 Days 3-5" N/A ASTM C-143 ASTM C-172 ASTM C-39 PROJECT DATA CONCRETE CLASS: 9349 PLACEMENT DATE: 10/27/1998 BATCH TIME: 9:46am TIME SAMPLED: 10:10am BY: Vince MeManis WEATH ER CONDITIONS: TEMPERATURE (F) - AIR TRUCKNO: 841 AIR CONTENT (%): N/A PLACEMENT LOCATION: See Page 1 Cool, sunny 72 F CONCRETE: 76 F TICKET NO: 83379 UNIT WEIGHT (pc0: N/A SAMPLE LOCATION: J-5.5 REPORT OF TESTS CYLINDER MEASURED MARKED SLUMP DATE SET NO. (inches) TESTED 5 1 6.25 11/03/1998 5 2 6.25 11/03/1998 5 3 6.25 11/24/1998 5 4 6.25 11/24/1998 15 Gallons of water added MAXIMUM AGE LOAD (days) (Ibs.~rcO 7 92040 7 95840 Average 28 107240 28 102280 Average ACCUMULATIVE YARDS: 490 COMPRESSIVE STRENGTH (psi) 3250 3390 3320 3790 3620 3710 ~r FRACTURE TYPE 0ILL This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. Page 5 of 8 CONCRETE COMPResSIVE STRENGTH TE[" 8901 Carpenter Frwy., Suite#100 Dallas, Texas 75:147 Date of Service: 10/27/1998 Report No.: 9829178 Client No.: 71765000 Project No.: 43-2170-98 Report Date 11/25/1998 Client: Prentiss Properties Limited, Inc. Project: Lakeview Center Attn: David Glass Coppell, Texas 3860 W. Northwest Hwy. Dallas TX 75220 Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. SLUMP: AIR: TEST METHOD: CONTRACTOR: Butler Construction CONCRETE SUPPLIER: Pioneer PLANT: 22 SPECIFICATION REQUIREMENTS STRENGTH: 40002 psi ~ 28 Days 3-5" N/A ASTM C- 143 ASTM C- 172 ASTM C-39 PROJECT DATA CONCRETE CLASS: 9349 PLACEMENT DATE: 10/27/1998 BATCH TIME: 9:55am TIME SAMPLED: 10:45am BY: Vince McManis WEATH ER CONDITIONS: TEMPERATURE (F) - AIR TRUCK NO: 1815 AIR CONTENT (%): N/A PLACEMENT LOCATION: See Page 1 Warm, sunny 78 F CONCRETE: 72 F TICKET NO: 114497 UNIT WEIGHT (pet): N/A SAMPLE LOCATION: J.5-7 CYLINDER MEASURED MARKED SLUMP SET NO. (inches) 6 1 6.25 6 2 6.25 6 3 6.25 6 4 6.25 15 Gallons of water added. DATE TESTED 11/03/1998 11/03/1998 11/24/1998 11/24/1998 REPORT OF TESTS ACCUMULATIVE YARDS: 530 MAXIMUM COMPRESSIVE AGE LOAD STRENGTH ~ays) 0bs.~rce) (psi) 7 94160 3330 7 99980 3540 Average 3440 28 123310 4360 28 119020 4210 Average 4290 This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 01LL Page 6 of 8 CONCRETE COMPResSIVE STRENGTH Date of Service: 10/27/1998 Client No.: 71765000 Report No.: 9829178 Project No.: 43-2170-98 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Report Date 11/25/1998 Client: Prentiss Properties Limited, Inc. Atto: David Glass 3860 W. Northwest Hwy. Dallas TX 75220 Project: Lakeview Center Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. SLUMP: AIR: TEST METHOD: CONTRACTOR: Butler Construction CONCRETE SUPPLIER: Pioneer PLANT: 22 SPECIFICATION REQUIREMENTS STRENGTH: 40002 psi ~ 28 Days 3-5" N/A ASTM C-143 ASTM C- 172 ASTM C-39 PROJECT DATA CONCRETE CLASS: 9349 PLACEMENT DATE: 10/27/1998 BATCH TIME: 10:45am TIME SAMPLED: 12:00pm BY: Vince McManis WEATHER CONDITIONS: TEMPERATURE (F) - AIR TRUCK NO: 1807 AIR CONTENT (%): N/A PLACEMENT LOCATION: See Page 1 Warm, cloudy, humid 81 F CONCRETE: 70 T1Cr~T NO: 114497 UNIT WEIGHT (pc0: N/A SAMPLE LOCATION: K-8.5 CYLINDER MEASURED MARKED SLUMP SET NO. (inches) 7 1 6.00 7 2 6.00 6.00 6.00 7 3 7 4 DATE TESTED 1/03/1998 1/03/1998 1/24/1998 1/24/1998 REPORT OF TESTS ACCUMULATIVE YARDS: MAXIMUM COMP~SS~VE AGE LOAD STRENGTH (days) (Ibs.~rce) (psi) 7 97150 3440 7 90740 3210 Average 3330 28 129510 4580 28 119750 4230 Average 4410 630 FRACTURE TYPE 0ILL This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. Page 7 of 8 CONCRETE COMPResSIVE STRENGTH 8901 Carpenter Frwy., Suite #100 Dallas, T~as 75247 Date of Service: 10/27/1998 Report No.: 9829178 Client No.: 71765000 Project No.: 43-2170-98 Report Date 11/25/1998 Client: Prentiss Properties Limited, Inc. Project: Lakeview Center Attn: David Glass Coppell, Texas 3860 W. Northwest Hwy. Dallas TX 75220 Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. SLUMP: AIR: TEST METHOD: CONTRACTOR: Butler Construction CONCRETE SUPPLIER: Pioneer PLANT: 22 SPECIFICATION REQUIREMENTS STRENGTH: 40002 psi ~ 28 Days 3-5" N/A ASTM C- 143 ASTM C- 172 ASTM C-39 PROJECT DATA CONCRETE CLASS: 9349 PLACEMENT DATE: 10/27/1998 BATCH TIME: 12:30pm TIME SAMPLED: l:00pm aY: Vince McManis WEATHER CONDITIONS: TEMPERATURE (F) - AIR TRUCK NO: 1882 AIR CONTENT (%): N/A PLACEMENT LOCATION: See Page 1 Warm, sunny, humid 82 F CONCRETE: 78 TICKET NO: 083410 UNIT WEIGHT (.ncO: N/A SAMPLE LOCATION: K.5-9.5 CYLINDER MARKED SET NO. MEASURED SLUMP (inches) 8 1 6.25 8 2 6.25 8 3 6.25 8 4 6.25 REPORT OF TESTS MAXIMUM DATE AGE LOAD TESTED (days) (lbs. force) 11/03/1998 7 120390 11/03/1998 7 117890 Average 11/24/1998 28 140110 11/24/1998 28 145080 Average availability to point Note: Samples taken from mixer truck due to contractor added water as needed. ACCUMULATIVE YARDS: COMPRESSIVE STRENGTH ~si) 4260 4170 4220 4950 5130 5040 of discharge, 720 FRACTURE TYPE Technician: Vince McManis Report Distribution: (I) Prentiss Properties Limited, Inc. (I) Alliance Architects, Inc. (1) Halff Associates (1) Mullen & Powell Technistructures, 1 Started: 3:00am Finished: 2:00pm (I) Butler Construction (1) City of Copp¢ll (1) City of Coppcll Vice President This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HDC Engineering, Inc. 01LL Page 8 of 8