Loading...
Park West CC(7)-LR 981110 IN-PLACE DENSITY '_;STING 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: Client No.: Client: 10/26/1998 71765000 Prentiss Properties Limited, Inc. Attn: DavidGlass 3860 W. Northwest Hwy. Dallas TX 75220 Report No.: 9829771 Project No.: 43-2170-98 Project: Lakeview Center Coppell, Texas Report Date 11/10/1998 Services: In-place density testing. CONTRACTOR: Butler Construction PROJECT DATA Laboratory Test Method: ASTM D-698 Field Test Method: ASTM D-2922 ASTM D-3017 MOISTURE DENSITY RELATIONS: M/D No. Description Maximum Moisture % Density pcf Project Requirements Moisture Density Reddish brown clayey sand w/clay balls and gravel 11.5 123.5 FIELD DENSITY TESTS -2/+2% 95% TEST NO TEST LOCATION M/D MOISTURE DRY DENSITY DENSITY No. (%) (pcf) (% max) 447 448 449 450 451 452 453 454 455 456 457 458 SE Comer 60'W and 20'N SE Comer 60'W and 80'N SE Comer 60'W and 190'N SE Comer 100'W and 210'N SE Comer 100'W and 140'N SE Comer 100'W and 70'N SW Comer 40'N and 60'E SW Comer 40'N and 100'E SW Comer 40'N and 160'E SW Comer 90'N and 200'E SW Comer 90'N and 120'E SW Comer 90'N and 60'E 1 12.1 119.9 97 1 11.9 119.7 97 1 12.0 120.3 97 1 12.3 120.2 97 1 12.0 119.9 97 1 12.4 120.0 97 1 12.1 120.4 98 I 12.3 120.5 98 1 11.9 120.3 97 1 12.1 119.9 97 1 11.7 120.0 97 1 12.0 120.2 97 07DG This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. Page 1 of 2 Report No.: 982977 TEST MfD MOISTURE NO TEST LOCATION No. (%) DRY DENSITY (pcf) 459 SW Comer 140'N and 90'E 1 12.0 Test results on this report meet project specification. 119.9 Recheck Prior to Concrete Placement DENSITY (% max) 97 Technician: Tex King Report Distribution: (1) Prentiss Properties Limited, Inc. (1) Alliance Architects, Inc. (1) Halff Associates (1) Mullen & Poweli Technistructures, I (1) Butler Construction (1) City of Coppell (1) City of Coppell H~ Engin~ Eugene Harbour Vice President This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 07DG Page 2 of 2