Loading...
Park West CC(1)-LR 950717REPORT NO.: PROJECT: LOCATION: ARCHITECT/ENGINEER: McFadden & Miller Marc .~ Mye r.s REPORT~o TO: - ~* 2 2166.2 4~ NO.: Park West Commerce Center Piers - F-24, E-24 and D-24 reed engineering GEOTECHNI~.AL CONSULTANTS CONCRETE COMPRESSION TEST REPORT DATE CAST: SPECIFICATION: QUANTITY REPRESENTED: 06/19/95 3000 PSI 10/10 yds SAMPLED BY: F. Palmer DATE: 07/17/95 BY ORDER OF: 06/26/95 ORDER NUMBER: Client (6 x 12 INCH) NOMINAL CYUNDER SIZE: AREA-20.26 SQ. IN. lABORATORY NUMBER FqELD NUMBER: PW061901 PW061902 82,000 99,600 7 28 2900 3520 MAXIMUM LOAD, LBS: AGE WHEN TESTED, DAYS: COMPRESSIVE STRENGTH, PSI: AVERAGE STRENGTH, PSI: PW061903 103,800 28 3670 TYPE BR~K: CONICAL (U.N.O.) REM~KS: Does comply with Specification 3600 METHOD OF CURING: FIELD 1 TEMPERATURE: AMBIENT 91 'F DAYS. ~BORATO.Y FROM 06 / 20 / 95 TRANSPORTED BY M,X 88 'F. AIR CONTENT Reed SLUMP 5.25 INCHES 11ME OF SAMPLE: 0 9: 4 5 8OURCE OF CONCRETE: TXI MIX CODE: PICK-UP CHARGE: Y~ NO TICKET NO.: 402046 FINE AGGREGATE: COARSE AGGREGATE: WATER: CEMEN'F: FLY ASH: ADMIXTURE(S): UNIT WEIGHT PCF YIELD CF/CY mSTR,BUT~,: (1) Marc Myers Company/Mr. Richard Crow (1) McFadden & Miller Construction/Mr. Dave VanDemee: (1) Comerica Bank/Mr. Alan Williams TEST METHODS: ASTM C 31, C 39, C 143. C 173, C 192, C 231, OR C 1064 PAGE 1 ]. 2424 STUTZ DRIVE · SUITE400 · DALLAS, TEXAS75235 · 214/350-5600 · {FAX) 214/350-0019