Loading...
Park West CC(6)-LR 970626 REPORT OF REINFORCING STEEL PLACEMENT OBSERVATION Parkwest Center II Airline Drive at Beltline Road Coppell, Texas REPORTED TO: Insignia Commercial Group REPORT NO. 7 3100 Monticello, Suite 400 REPORT DATE: 06-26-97 Dallas, Texas 75205 REG PROJECT NO. 3486.1 A'r'I-N: Mr. John Stadler DATE OBSERVED: 06-20-97 TECHNICIAN: B. Woolwine CONTRACTOR: Bob Moore Construction Slab: 3rd placement from line I - 12 and line H - K. '!.:'i:~:i:=~:::::::::::::::::::::::::::::::::::::::::::~?~:i~:?i?~!:~::?::::~?:~i~:.:!~.~i::i:::::::~:~:~:~:~:?~?::~i~i:::i::~i:?~.~i::i:Ji:~i~::~i~i::~::~:~:~:~:i:~:~:~(:~i::?~:::(~:::=.(:~::i~:~.?:~!~:=~i~:-I:~::=:'::i:/~i~ii:?-::i:::i~:i;:i:~:?:'.'! ::i~:~:~-i:i:::::~:~=:~i~:~i:i.:?::::'=::='::i!~i~.~:::(:::i~i:.i'i?:i::::i These deviations were corrected __ not corrected _~X No deviations were observed. All reinforcing steel appeared to be placed in accordance with contract documents & CRSI. Distribution: (1) Insignia Commercial Group/ Submitted by: Mr. Jol~n Stadler (1) Hardy McCullah/MLM Architects/ REED ENGINEERING GROUP, INC. Mr. Norman Coates (1) TenEyck*Merritt*Barnett*Pitt/ Original Signed By Mr. Frank Merritt (1) Bob Moore Construction/ Ronald F. Reed Mr. Ed T. McGuire RFR/kff (1) City of Coppell/Mr. Lee Stone (1) City of Coppell/Mr. Larry Davis 2424 STUTZ DR. · SUITE 400 · DALLAS. TX 75235 · T=L [214] 350 5600 · FA.X [214] 350 0019 GEO-ECHN CAI. AND ~ ~ ~ I I p Eh.v ~O~II~I_='xlTA_ COIX.$L,_TA~IT~ REPORT OF REINFORCING STEEL PLACEMENT OBSERVATION Parkwest Center II Airline Drive at Beltline Road Coppell, Texas REPORTED TO: Insignia Commercial Group REPORT NO. 8 3100 Monticello, Suite 400 REPORT DATE: 06-26-97 Dallas, Texas 75205 REG PROJECT NO. 3486.1 A'I'TN: Mr. John Stadler DATE OBSERVED: 06-21-97 TECHNICIAN: H. Johnson CONTRACTOR: Bob Moore Construction Floor Slab: F-H, 22-12. ;i::::.RE~i~K~::i::~i~;i ':: i.::i:ii!.i:.i~ ::':::::~'!:'i.::: :i :.i~::i:.:ii:i..i. i:~::.:~.~".'~.:i ?:':?!'~ii:.i:ii::i .i':i:i?~ '-i'.[::i?:i:~i .i .~:::i::[~ ::: i..i~.[::?:-:: i:.i~.[: i:: i: i::i.'::-:~ :~::?~ ~: :~::~.~.:-::.::. ~ :?.'i-::: 'i :i':i ?~ :i::[-.i: i'.::: ::~'~:::'~.~::.'i :i ~i~i?~i:-[:'~.:::?~ :ii:[~:i['i.:~.:~ i ii::.~:.i:. ?~:?.i~?:.::?:~::i:. i~ Sheet 8.1 These deviations were corrected __ not corrected ~ No deviations were observed. All reinforcing steel appeared to be placed in accordance with contract documents & CRSI. Distribution: (1) Insignia Commercial Group/ Submitted by: Mr. John Stadier (1) Hardy McCullah/MLM Architects/ REED ENGINEERING GROUP, INC. Mr. Norman Coates (1) TenEyck*Merritt*Barnett*Pitt/ Original Signed By Mr. Frank Merritt (1) Bob Moore Construction/ Ronald F. Reed Mr. Ed T. McGuire RFR/kff (1) City of Coppell/Mr. Lee Stone (1) City of Coppell/Mr. Larry Davis 2424 STUTZ DR. · SUITE 400 · DALLAS. TX 75235 · TEL [214] 350 5600 ' =~X [214] 350 0019