Park West CC(1)-LR 950808 17 2166.2 REPORT ~.: JOB NO.: Park West Commerce Center PROJE~: Floor slab - 650'S, 60'E of NW LOCk. N: building corner reed engineering GE~TECHNICAL CONSULTANTS CONCRETE COMPRESSION TEST REPOFIT DATE CA~T: SPECIFICATION: QUANTITY REPRESENTED: ARCH~CT~NGINEER: McFadden & Miller Marc Myers REPORTED TO: DATE: 07/11/95 3000 PSI 60/470 yds SAMPLED BY: B · Lucas 08/08/95 aY ORDER OF: 07/18/95 ORDER NUMBER: Client (6 x 12 INCH) NOMINAL CYLINDER SIZE: AREA-28.26 SQ. IN. RE~ .UMSER: PW071101 112,000 MAXIMUM LOAD, LBS: 7 AGE WHEN TESTED, DAYS: 3960 COMPRESSIVE STRENGTH. PSI: AVERAGE STRENGTH. PSi: ~BORAT~Y NUMBER PW071102 138,000 28 4880 PW071103 142,000 28 5020 TYPE BREAK: CONICAL (U.N.O.) REMARKS: Does comply with Specification 4950 METHOD OF CURING: FIELD 1 DAYS, ~TORY FROM 07 / 12 / 95 TRANSPORTED aY Re ed TEMPERATURE: AMBIENT 7 5 M,X 8 6 'r. A~R CONTENT ~UMP 6 . 5 0 INCHES TI.E OF ~MPLE: 06: 50 80URCE OF CONCRETE: TX I MIX CODE: 39 PICK-UP CHARGE: Y~ TICKET NO.: 4 15 12 6 NO FINE AGGREGATE: COARSE AGGREGATE: WATER: CEMENT: FLY ASH: ADMIXTURE(S): UNIT WEIGHT YIELD PCF CF/CY D,STR,SUT~N: (1) Marc Myers Company/Mr. Richard Crow (1) McFadden & Miller Construction/Mr. Dave (1) Comerica Bank/Mr. Alan Williams (1) AECC, Inc./Mr. Andy Brundige StGNED TEST METHODS: ASTM C31. C39, C143, C173, C 192. C231, ORC1064 PAO~; 2424 STUTZ DRIVE · SUITE400 · DALLAS, TEXAS75235 · 214/350-5600 · (FAX) 214/350-OO19 3 REPORT NO.: PROJECT: LOCATK)N: ARCHITECT/ENGINEER: McFadden & Miller CONTRACTOR: Marc Myers REPORTED TO: 17 Park West Commerce Center Floor slab - 175'N, 60'E of SW building corner reed engineering CONCRETE COMPRESSION TEST REPORT 2166.2 JO~ NO.: GEOTECHNICAL CONSULTANTS DATE CAST: SPECIFICATION: QUANTtTI' REPRESENTED: SAMPLED BY: DATE: 08/08/95 BYORDEROF: 07/18/95 ~DER NUMBER: 07/11/95 3000 PSI 260/420 yds B. Lucas Client (6 x 12 INCH) NOMINAL CYLINDER SIZE: AREA-28.26 SQ. IN. FIELD NUMBER: PW 071104 87,500 MAXIMUM LOAD, LBS: 7 AGE WHEN TESTED, DAYS: 3090 COMPRESSIVE STRENGTH. PSI: AVERAGE STRENGTH, PSI: ~BORATORY NUMBER PW071105 115,000 28 4070 PW071106 117,000 28 4140 TYPE BREAK: CONICAL (U...O.) Does comply with Specification REMARKS: 4110 METHOD OF CURING: FIELD TEMPERATURE: AMBIENT TIME OF SAMPLE: 0 9: 1 0 1 DAYS, LABORATORY FROM 8 0 'F M,X 8 8 SOURCE OF CONCRETE: TXI 07 / 12 / 95 TRANSPORTED .Y Reed CF0 AIR CONTENT q~. SLUMP 6. 50 PiCK-UP CHARGE: Yi~ MIX CODE: 3 9 TICKET NO.: 4 ~L 5 3 3 3 INCHES NO RNE AGGREGATE: COARSE AGGREGATE: WATER: CEMENT: FLY ASH: ADMIXTURE(S): UNIT WEIGHT PCF YIELD CF/CY DISTRIBUTION: (1) Marc Myers Company/Mr. Richard Crow (1) McFadden & Miller Construction/Mr. Dave VanDeme, (1) Comerica Bank/Mr. Alan Williams (1) AECC, Inc./Mr. Andy Brundige SIGNED 2 TEST METHOOS: ABTM C 31. C 39. C 143. C $73. C 192. C 231. ORC 1064 PAGE OF 2424 STUTZ DRIVE · SUITE400 · DALLAS, TEXAS75235 · 214/350-5600 · (FAX)214/350*O019 3 reed engineering CONCRETE COMPRESSION TEST REPORT 17 Park West Commerce Center Piers - A-4, A-3.5, A-3, A-2.5 REPORT NO.: PROJECT: LOCATION: ARCHITECT/ENGINEER: McFadden & Miller Marc Myers REPORTED TO: 2166.2 JOB NO.: GEOTECHNICAL CONSULTANTS DATE CAST: SPECIFICATION: QUANTITY REPRESENTED: 07/11/95 3000 PSI 20/40 yds SAMPLEDBY: B. Woolwine DATE: BY ~R OF: 08/08/95 07/18/95 ORDER NUMBER: Client (~ x 12 INCH) NOMINAL CYLINDER SIZE: AREA-28.2~ SQ. IN. FIELD NUMBER: PW071107 87,000 MAXIMUM LOAD, LBS: 7 AGE WHEN TESTED, DAYS: 3080 COMPRESSIVE STRENGTH. PSI: AVERAGE STRENGTH, PSI: ~BORATORY NUMBER PW071108 116,000 28 4100 PW071109 117,000 28 ~PE WEAK: ~NICAL (U.N.O.) REMARKS: Does comply with Specification 4140 4120 METHOD OF CURING: FIELD 1 DAYS. LABORATORY FROM 0 7 / 12 / 9 5 TRA.$PORTED BY TEMPERATURE: AMBIENT 8 2 'F MIX 8 6 *F. AIR CONTENT '~, Reed SLUMP 4 . 5 0 INCHES TIME OF SAMPLE: 10: 5 0 BOURCE OF CONCRETE: TXI MIX CODE: 5 PICK-UP CHARGE: Y~ TICKET NO.: 415494 NO FINE AGGREGATE: COARSE AGGREGATE: WATER: CEMENT: FLY ASH: ADMIXTURE(S): UNIT WEIGHT PCF YIELD CF/CY D,Sm,S~.O~: (1) Marc Myers Company/Mr. Richard Crow (1) McFadden & Miller Construction/Mr. Dave V~ (1) Comerica Bank/Mr. Alan Williams (1) AECC, Inc./Mr. Andy Brundige SIGNED 3 TEST METHODS: ASTM C31. C39. C 143. C 173. C 192. C231, OR C 1064 pAOF OF 2424 STUTZ DRIVE · SUITE400 · DALLAS, TEXAS75235 · 214/350-5600 · (FAX) 214/350-O019