Loading...
Park West CC(7)-LR 981022CONCRETE COMPR oSIVE STRENGTH TEL? 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 10/09/1998 Report No.: 9827091 Client No.: 71765000 Project No.: 43-2170-98 Report Date 10/22/1998 Client: Prentiss Properties Limited, Inc. Project: Lakeview Center Attn: David Glass Coppell, Texas 3860 W. Northwest Hwy. Dallas TX 75220 Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. SLUMP: AIR: TEST METHOD: CONTRACTOR: Butler Construction CONCRETE SUPPLIER: Pioneer PLANT: 22 SPECIFICATION REQUIREMENTS STRENGTH: 3000 psi ~ 28 Days 5-7" N/A ASTM C- 143 ASTM C-172 ASTM C-39 SAMPLE LOCATION: Pier I/9 CYLINDER MEASURED MARKED SLUMP DATE SET NO. (inches) TESTED I 1 5.75 10/16/1998 PROJECT DATA CONCRETE CLASS: 9337 PLACEMENTDATE: 10/09/1998 BATCHTIME: 10:30am TIME SAMPLED: ll:50am BY: Mike Shields WEATHER CONDITIONS: TEMPERATURE (F) - AIR TRUCK NO: 5 1 5 AIR CONTENT (%): N/A PLACEMENT LOCATION: Sunny and Dry 74 F CONCRETE: 84 F TICKET NO: 76654 UNITWEIGHT (pc/): N/A Piers-I/9, J/9, K/9, K/8, K/7 and K/6 REPORT OF TESTS ACCUMULATIVE YARDS: MAXIMUM COMPRESSIVE AGE LOAD STRENGTH (days) (lbs. force) (psi) 7 96590 3420 1 2 5.75 11/06/1998 I 3 5.75 11/06/1998 28 10 FRACTURE TYPE Technician Time: See Report #9827090. Technician: Mike Shields Report Distribution: (I) Prentiss Properties Limited, Inc. (I) Alliance Architects, Inc. (I) Halff Associates (I) Mullen & Powell Technistructures, I Started: Finished: (1) Butler Construction (1) City of Coppell (I) City of Coppell H~~, Inc. Eugene Harbour Vice President This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 01TM Page 1 of I 2ONCRETE COMPRE (' ' IVE STRENGTH TES )ate of Service: 10/12/1998 Report No.: Client No.: 71765000 Project No.: Client: Prentiss Properties Limited, Inc. Project: Attn: David Glass 3860 W. Northwest Hwy. Dallas TX 75220 9827275 43-2170-98 Lakeview Center Coppell, Texas 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Report Date 10/22/1998 Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. SLUMP: AIR: TEST METHOD: COSTRACTOR: Butler Construction CONCRETE SUPPLIER: Pioneer I, LANT: 22 SPECIFICATION REQUIREMENTS STR~NGT~I: 3000 psi @ 28 Days 5-7" N/A ASTM C- 143 ASTM C-172 ASTM C-39 SAMPLE LOCATION: Pier-C/8 PROJECT DATA CONCRETE CLASS: 9337 PLACEMENT DATE: 10/12/1998 BATC~I T~tE: 12:05pm TIME SAMPLED: 1:10pm BY: Mike Shields WEATHER CONDITIONS: Sunny and Dry TEMPERATURE (F) - AIR 84 g CONCRETE: 86 Ir TRUCK NO: 512 TICKET NO: 767925 AIR CONTENT (%): N/A uNrr WEIGHT (peO: N/A PLACEMENT LOCATION: REPORT OF TESTS CYLINDER MEASURED MAXIMUM MARKED SLUMP DATE AGE LOAD SET NO. (inch.) TESTED (days) (lbs. force) 1 1 5.75 10/19/1998 7 94950 ACCUMULATIVEYARDS: 10 COMPRESSIVE STRENGTH (psi) 3360 FRACTURE TYPE 1 2 5.75 1 3 5.75 11/09/1998 28 11/09/1998 28 Technician Time: See Report #9827274. Teelmieian: Mike Shields Report Distribution: (1) Prentiss Properties Limited, Inc. (1) Alliance Architects, Inc. (1) Halff Associates (1) Mullen & Poweli Teehnistructures, I Started: Finished: (1) Butler Construction (1) City of Coppeli (1) City of Coppell EnTg, Inc. Eu~bour Vice President This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. Pa.e I of 1 IN-PLACE DENSITY / STING Date of Service: Client No.: Client: Services: 10/09/1998 71765000 Prentiss Properties Limited, Inc. Attn: David Glass 3860 W. Northwest Hwy. Dallas TX 75220 In-place density testing. 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Report No.: 9827039 Project No.: 43-2170-98 Project: Lakeview Center Coppell, Texas Report Date 10/22/1998 CONTRACTOR: Butler Construction PROJECT DATA Laboratory Test Method: ASTM D-698 Field Test Method: MOISTURE DENSITY RELATIONS: M/D No. Description 1 Lt Brown & Tan Sandy Clay w/Limestone Moisture% 20.5 FIELD DENSITY TESTS Maximum Density pcf 99.5 ASTM D-2922 ASTM D-3017 Project Requirements Moisture Density -1/+3% 95% TEST NO TEST LOCATION 8" Water Line A 411 at Station 15+50, 2nd Lift 412 at Station 15+70, 1st Lift 413 at Station 16+90, 2nd Lift 414 at Station 17+00, 1st Lift 415 at Station 18+40, 2nd Lift 416 at Station 18+50, 1st Lift 417 at Station 19+20, 2nd Lift 418 at Station 19+30, 1st Lift 419 at Station 20+70, 2nd Lift 420 at Station 21+00, 1st Lift Technician: Tex King Report Distribution: (1) Prentiss Properties Limited, Inc. (1) Alliance Architects, Inc. (1) Halff Associates (1) Mullen & Powell Technistructures, l M/D MOISTURE DRY DENSITY DENSITY No. (%) (pc0 (% mE) 1 20.9 96.0 97 1 21.2 96.3 97 1 21.0 96.2 97 1 21.3 96.4 97 1 21.3 96.4 97 1 21.2 95.6 96 1 21.2 95.8 96 1 21.4 96.1 97 1 19.9 95.4 96 1 20.3 95.2 96 Test results on this report meet project specification. (1) Butler Construction (1) City of Coppell (I) City of Coppell Engineering, Inc. Eugene Harbour Vice President This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 07TMP Page I of 1