Park West CC(1)-LR 950824REPORT NO.:
PROJECT:
LOCATION:
25
JOB NO.:
Park West Commerce Center
Tilt wall panel - #50
reed engineering
CONCRETE COMPRESSION TEST REPORT
2166.2
SPECIFICATION:
QUANTITY REPRESEHTED:
07/27/95
3000 PSI
10/180 yds
ARCH~NGINEER:
McFadden & Miller
Marc Myers
REPORTED TO:
DATE:
8AM~EDBY: B. Lucas
08/24/95 s¥ ORDER OF:
08/03/95
ORDER NUMBER:
Client
(6 x 12 INCH) NOMINAL CYUNDER SIZE: AREA-28.26 SQ. IN.
LABORATORY NUMBER
FIE~ .UMBER: PW072701 PW072702
103,500 128,000
MAXIMUM LOAD, LBS:
7 28
AGE WHEN TESTED, DAYS:
3660 4530
AVERAGE STRENGTH, PSI:
4740
BREAK: CON.AL (U.N.O.)
REM~S: Does comply with Specification
PW072703
140,000
28
4950
METHOO OF CURING: FIELD
TEMPERATURE: AMBIENT
TIME OF SAMPLE: 07: 15
SOU~,CE O~ C~NCRETE: TX I
1 D^YS, LA~RATORY ~ROM 07 / 28 / 95
.,X 89 '~,
MIX CODE:
AIR CONTENT
39
77 'F
TRANSPORTED BY Reed
SLUM, 5.00
PICK-UP CHARGE: Y~
T,CKET NO.: 426647
INCHES
NO
FINE AGGREGATE:
COARSE AGGREGATE:
WATER:
CEMENT:
FLY ASH:
ADMIXTURE(S):
UNIT WEIGHT PCF
YIELD CF/CY
D~.~BU~ON: (1) Marc Myers Company/Mr. Richard Crow
~1) McFadden & Miller Construction/Mr. Dave
(1) Comerica Bank/Mr. Alan Williams
(1) AECC, Inc./Mr. Andy Brundige $~NED
TEST METHOOS: ASTM C $,. C 39, C ,4~. C 17~. C 192. C 23,.OR C 1064 PAGE
2424 STUTZ DRIVE · SUITE400 · DALLAS, TEXAS75235 · 214/350-5600 · (FAX) 214/350-0019