Loading...
Park West CC(7)-LR 980911IN-PLACE DENSITY /' :STING 8901 Carpenter Frwy. Suite #100 Dallas, Texas 7S247 Date of Service: Client No.: Client: 09/04/1998 71765000 Prentiss Properties Limited, Inc. Attn: DavidGlass 3860 W. Northwest Hwy. Dallas TX 75220 Report No.: 9823502 Project No.: 43-2170-98 Project: Lakeview Center Coppell, Texas Report Date 09/11/1998 Services: In-place density testing. CONTRACTOR: Butler Construction PROJECT DATA Laboratory Test Method: ASTM D-698 Field Test Method: ASTM D-2922 ASTM D-3017 MOISTURE DENSITY RELATIONS: M/D No. Description Maximum Moisture % Density pcf Project Requirements Moisture Density Reddish Brown Clayey Sand w/Clay Balls & Gravel 11.5 123.5 FIELD DENSITY TESTS -2~2% 95% TEST NO TEST LOCATION M/D MOISTURE DRY DENSITY DENSITY No. (%) (pcf) (% max) Southwest Wing 223 SW Comer 402q & 50'E, Select, 1st Lift 224 SW Comer 40~ & 90'E, Select, 1st Lift 225 SW Comer 40'N & 130'E, Select, 1st Lift 226 SW Comer 402q & 170'E, Select, 1st Lift 227 SW Comer 402q & 200'E, Select, 1st Lift 228 SW Comer 902q & 190'E, Select, 1st Lift 229 SW Comer 90'N & 130'E, Select, 1st Lift 230 SW Comer 90~ & 90'E, Select, 1st Lift 231 SW Comer 90'N & 60'E, Select, 1 st Lift 232 SW Comer 90'N & 10'E, Select, 1st Lift Technician: Tex King Report Distribution: (1) Prentiss Properties Limited, Inc. (1) Alliance Architects, Inc. ( I ) Halff Associates (I) Mullen & Powell Tcchnistmctures, l 1 12.1 118.8 96 1 11.9 119.2 97 I 12.0 118.8 96 1 12.4 119.3 97 1 12.1 118.7 96 1 12.2 119.1 96 1 12.0 119.1 96 1 12.4 118.9 96 1 12.3 119.4 97 1 12.1 119.2 97 Test results on this report meet project specification. (1) Butler Construction (I) City of Coppell (1) City of Coppell E~, Inc. Vice President This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 07TMP Page 1 of 1 ,IN-PLACE DENSITY STING 8901 Carpenter Frwy. Suite #100 Dallas, Texas 75?.47 Date of Service: Client No.: Client: 09/03/1998 71765000 Prentiss Properties Limited, Inc. Atto: DavidGlass 3860 W. Northwest Hwy. Dallas TX 75220 Report No.: 9823369 Project No.: 43-2170-98 Project: Lakeview Center Coppell, Texas Report Date 09/11/1998 Services: In-place density testing. CONTRACTOR: Butler Construction PROJECT DATA Laboratory Test Method: AST1V[ D-698 Field Test Method: ASTM D-2922 ASTM D-3017 MOISTURE DENSITY RELATIONS: M/D No. Description Maximum Moisture % Density pef Project Requirements Moisture Density Reddish Brown Clayey Sand w/Clay Balls & Gravel 11.5 123.5 FIELD DENSITY TESTS -2/+2% 95% TEST NO TEST LOCATION M/D MOISTURE DRY DENSITY DENSITY No. (%) (PC0 (% max) East Wing, South Half 211 SE Comer 20'W & 202q, Select, 1 st Lift 212 SE Comer 20'W & 402q, Select, 1st Lift 213 SE Comer 20'W & 802q, Select, 1st Lift 214 SE Comer 20'W & 1202q, Select, 1st Lift 215 SE Comer 20'W & 1802q, Select, 1st Lift 216 SE Comer 20'W & 220'N, Select, 1st Lift 217 SE Comer 100'W & 240'N, Select, 1st Lift 218 SE Comer 100'W & 190'N, Select, 1st Lift 219 SE Comer 100'W & 140'N, Select, 1st Lift 220 SE Comer 100'W & 902q, Select, 1 st Lift 221 SE Comer 100'W & 60'N, Select, 1st Lift 1 11.9 120.0 97 1 12.1 119.7 97 1 12.3 119.9 97 1 12.0 119.4 97 1 11.7 119.5 97 1 12.4 119.2 97 1 12.2 119.7 97 1 12.1 119.8 97 1 12.3 119.5 97 1 12.5 119.7 97 1 12.6 120.0 97 This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 07TMP Page 1 of 2 · Report No.: 9823369 TEST NO 222 M/D MOISTURE TEST LOCATION No. (%) SE Comer 100'W & 20'N, Select, 1st Lift 1 12.3 Test results on this report meet project specification. DRY DENSITY ~e0 119.9 DENSITY (% max) 97 Technician: Tex King Report Distribution: (1) P~ntiss Properties Limited, Inc. (1) Alliance Architects, Inc. ( 1 ) Halff Associates (1) Mullen & Powell Technistmctures, I (i) Butler Construction (!) City of Coppell (1) City of Coppell Eugene Harbour Vice President This report is exclusively for the use of the client indicated above and shall not bc reproduced except in full without the written approval of HBC Engineering, Inc. 07TMP Page 2 of 2