Park West CC(1)-LR 950922 (2)t LC'O ,.SEP 2 '7
reed engineering
GEOTECHNICAL CONSULTANTS
September 22, 1995
Project No. 2166.2/Report No. 8
Marc Myers Company
3811 Turtle Creek Boulevard, Suite 1020
Dallas, Texas 75219
ATTN: Mr. Richard Crow
Re:
Construction Materials Testin9
Park West Commerce Center
Airline Drive and Executive Drive
Coppell, Texas
Gentlemen:
Submitted here are the results of testin9 and observation of
construction materials at the referenced project. This report
addresses the activities for the period of September 7 through 14,
1995.
Durin~ the referenced period, nine field density tests were taken on
pavin~ sub~rade. Test results are shown on Plate 1. Where tested,
materials were found to be in compliance with project specifications,
except as noted. As of this date two failin9 areas have not been
retested. The areas will be retested followin~ reworkin~ of the
sub~rade by the contractor. Failin~ tests are noted in lower case
letters.
Additional reports will be submitted as the work progresses.
have any questions, do not hesitate to call.
If you
Sincerely,
GII~ERIN~~.NC.
Ro~.E.'
BES/RFR/msm
copies submitted: (1) Marc Myers Company/Mr. Richard Crow
McFadden & Miller/Mr. Dave VanDemeer
(1) Comerica Bank/Mr. Alan Williams-
(1) AECC, Inc./Mr. Andy Brundige
2424 STUTZ DRIVE · SUITE400 · DALLAS, TEXAS75235 · 214/350-5600 · (FAX) 214/350-O019
reed engineering
PARK WEST COMMERCE CENTER
AIRLINE DRIVE AND EXECUTIVE DRIVE
COPPELL, TEXAS
REPORT NO. 8
Test
Date No.
09-07-95 312
313
314
315
316
09-14-95 317
318
319
320
Field Density Tests
Location
Depth
Below Unit
Final Dry
S.G. Weight
(feet) (pcf)
Moisture
Content Curve
(%) No.
225' S, 65'E (1) 0.0 94.7 25.6
175'S, 135'E(1) 0.0 94.7 29.0
285'S, 65' E (1) 0.0 97.8 22.3
340'S, 66'E (1) 0.0 96.1 21.9
415' S, 103'E(1) 0.0 98.0 22.9
90' S,400'W(2) 0.0 96.2 19.0
85'S, 600'W(2) 0.0 97.1 19.2
100'S, 750'W(2) 0.0 87.3 27.9
ll0'S, 850'W(2) 0.0 86.9 26.5
Com-
pac-
tion
Level
(%)
7 96.7
1 97.7
7 99.9
7 98.2
7 100.1
1 99.4a
1 100.2b
2 97.2
2 96.8
Footnotes:
(i)
(2)
Measurements referenced from N.E. corner of
building.
Measurements referenced from S.E. corner of
building.
GE~ECHNICAL CONSULTANTS ,
PLATE 1