Loading...
Park West CC(1)-LR 950928OCT. REPORT NO.: PROJECT: LOCATION: 36 JOB NO.: Park West Commerce Center Tilt wall panel - #50 reed engineering GEOTECHNICAL CONSULTANTS CONCRETE COMPRESSION TEST REPORT 2166.2 DATE CAST: SPEClRCATION: QUANTITY REPRESENTED:. 08/31/95 3000 PSI 20/90 yds ARCHITECT/ENGINEER: ODm'RACTOR: McFadden & Miller Marc Myers REPORTED TO: DATE: SAMPLED BY: BY ORDER OF: 09/28/95 09 / 07 / 9 5ORDER NUMBER: B. Lucas Client (8 x 12 INCH) NOMINAL CYUNDER SIZE: AREA-28.26 SQ. IN. FIELD NUMBER: MAXIMUM LOAD, LBS: AGE WHEN TESTED, DAYS: COMPRESSIVE STRENGTH, PSI: AVERAGE STRENGTH, PSI: TYPE BREAK: CONICAL (U.N.O.) REMARKS: PW083101 97,200 7 3440 LABORATORY NUMBER PW083102 119,900 28 4240 Does comply with Specification PW083103 125,600 28 4440 4340 METHOD OF CURING: FIELD 1 TEMPERATURE: AMBIENT 81 TIME OF ,SAMPLE: 0 6: 5 9 SOURCE OF CONCRETE: ~ I DAYS, LABORATORY FROM · F .,X 9 3 A~, 09/01/95 TRANSPORTED BY °F, AIR CONTENT Reed SLUMP 5.50 PICK-UP CHARGE: M,X CODE: 40 TICKET NO.: 447213 INCHES NO FINE AGGREGATE: COARSE AGGREGATE: WATER: CEMENT: FLY ASH: ADMIXTURE(S): UNIT WEIGHT PCF YIELD CF/CY Dl~m,s~no,: (1) Marc Myers Company/Mr. Richard Crow (1) McFadden & Miller Construction/Mr. Dave (1) Comerica Bank/Mr. Alan Williams (1) AECC, Inc./Mr. Andy Brundige SIGNED TEST METHODS: ASTM C 31. C 39, C 143, C 173. C 192, C 231, ORC t064 PAGE 'I OF '1 2424 STUTZ DRIVE · SUITE400 · DALLAS, TEXAS75235 · 214/350-5600 · (FAX) 214/350-O019