Park West CC(11)-LR 981231CONTRA CT INSPECTION SER VICE, Inc.
4305 Glenwood Ct. Granbury, TX 76049 (817) 246-8096 FAX (817) 246-5889
REPORT OF
STRUCTURAL STEEL INSPECTION
Project:
Client:
Park West Commerce Center
Coppell, TX
Reed Engineering Group
2424 Stutz, Suite 400
Report No: 11706-8
Attention: Keith Atkins
Date of Service: 12-31-98
Dallas, TX 75235 Page 1 of 1
REPORT OF INSPECTION
Drawings utilized:
Structural
Locations/item inspected:
Building #2, reinspection of roof level metal deck installation.
Discrepancies/comments:
Reinspection of roof level metal deck puddle welds and side lap screws now determined to be
compliant.
Randy Walcker CWI #97121591
~ntract Inspection Service
Technician
This report is for the exclusive use of our client and shall not be modified or reproduced without written approval from said cfieut