ST9801-LR000815 (2) 9200 King Arthur Ddve Dallas, Texas 75247-3610 Phone 214/631-4372 Fax 214/631-4380 CONCRETE COMPRESSION TEST REPORT Report No.: Location: 101 Job No.: Coppell Road, Inlet at Eastwick Contractor: Ed Bell Construction Reported To: City of Coppell - Kenneth Griffin, P.E. (6 x 12 Inch) Nominal Cylinder Size: Area - 28.27 SO. IN. Field Number: Test Date: Maximum Load, LBS: Age When Tested, Days: Compressire Strength, PSI: Average Strength, PSh Type Break: Conical (U.N.O.) Remarks: CP081501 08/22/00 100720 7 3560 1520COP03 Date Cast: Specification: Quantity Represented: Sampled By: By Order Of: CP081502 09/12/00 28 C P081503 09/12/00 28 08/15/00 4000 psi @ 28 days 10 of 10 M. Yahyazadeh CP081504 HOLD HOLD Temperature: Ambient Time of Sample: 2:00 PM Source of Concrete: 102 o F Mix 98 ° F TXI - 8205 Air Content 4.2 % Slump Pick-Up Charge: Yes N/A Ticket No.: 2710321 3.0 Inches Fine Aggregate: Coarse Aggregate: Water: Cement: Fly Ash: Admixture(s): Distribution: City of Coppell - Larry Davis Unit Weight Yield Test Methods: ASTM C 31, C 39, C 173, C 192, C 231 and C 1064 OUR LETTERS AND REPORTS ARE FOR THE EXCLUSIVE USE OF THE CLIENT TO WHOM THEY ARE ADDRESSED AND APPLY ONLY TO THE SAMPLES TESTED. TEST RESULTS ARE NOT NECESSARILY INDICATIVE OF THE QUALITY OF APPARENTLY IDENTICAL OR SIMILAR SAMPLES. THIS REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL W1THOUT THE APPROVAL OF STANTECH.