Loading...
ST9801-LR000814 9200 King Arthur Drive Dallas, Texas 75247-3610 Phone 214/631-4372 Fax 214/631-4380 CONCRETE COMPRESSION TEST REPORT Report No.: Location: 100 Job No.: 1520COP03 Coppell Road, Inlet Tops at Minyards Contractor: Ed Bell Construction Reported To:' City of Coppell - Kenneth Griffin, P.E. (6 x 12 Inch) Nominal Cylinder Size: Area - 28.27 SO. IN. Date Cast: Specification: Quantity Represented: Sampled By: By Order Of: 08/14/00 4000 psi@28 days 8 of 8 R. Shaheed Field Number: Test Date: Maximum Load, LBS: Age When Tested, Days: Compressive Strength, PSI: Average Strength, PSI: Type Break: Conical (U.N.O.) Remarks: CP081401 CP081402 CP081403 CP081404 08~1~0 09/11/00 09/11/00 HOLD 76010 7 28 28 HOLD 2690 Temperature: Ambient 98 o F Mix 91 ° F Air Content 3.9 % Slump 4.25 Inches Time of Sample: 11:30 AM Pick-Up Charge: Yes Source of Concrete: TXI - 8205 N/A Ticket No.: 2708637 Fine Aggregate: Coarse Aggregate: Water: Cement: Fly Ash: Admixture(s): Distribution: City of Coppell - Larry Davis Unit Weight PCF Yield CF/CY Test Methods: ASTM C 31, C 39, C 173, C 192, C 231 and C OUR LETTERS AND REPORTS ARE FOR THE EXCLUSIVE USE OF THE CLIENT TO WHOM THEY ARE ADDRESSED AND APPLY ONLY TO THE SAMPLES TESTED. TEST RESULTS ARE NOT NECESSARILY INDICATIVE OF THE QUALITY OF APPARENTLY IDENTICAL OR SIMILAR SAMPLES, THIS REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL WITHOUT THE APPROVAL OF STANTECH.