Park West CC(4)-LR 940620 (2) '1 l'r con
CONSULTANTS, INC.
'~.:'I S-.::'~2~ :~=.~.,-:~ _c.-.._: :~:::-
;-.: '_..::~._~=:~!~ ::~. ,2'_', ~_'?__' ':-_'
,>-:.~':~:C 'J,' ;- ",' 7-"[_.
June 20, 1994 ::"'~":: ~'~: .... ::'~-~ '-
"--": ..' : .-.';~!~"S
Dupey Management Corporation
9015 Sterling Street
Irving, Texas 75063
Attn: Mr. Robert McCann Re: M J Designs Distribution Center
Coppell, Texas
Job No. 17931033
Dear Mr. McCann:
A Terracon Consultants, Inc. representative has performed field density testing on compacted
fills placed in the dock door and loading ramp areas for the referenced project. This report
covers the compaction testing services performed for June 3 and June 9, 1994. The results of
the field density tests performed during this period are attached to this report.
If you have any questions regarding this report or it's attachments, please contact this office.
Sincerely,
'-E~ric~elaff~, P. E~'
Project Engineer
EJC:kms
Attachments
Copy To: James, Harwick + Partners, Inc. Bob Moore Construction, Inc.
Mr. Mark Wolf Mr. Phil Bell
Albert I-lalff & Associates, Inc. City of Coppell
Mr. Paul Rielly Mr. Larry Davis
Mr. Lee Stone
Offices of The Terracon Companies. Inc. Geotechnical, Environmental and Materials Engineers
QUALITY ENGINEERING SINCE 1965
FIELD COMPACTION REPORT
Job No. 1793~033
Job Name and Location M J DESIGNS DISTRIBUI~ON ~ Date 6-20-93
Architect or Engineer JAMES, ~CK + P~, INC.
Contractor BOB FI~)RE CE~S'IR~
Lift No. Haximum In-Place In-Ptace
Test Date Location or Ht[. Lab Dry get gater Dry Percent Comments
No. E[ev. Hark Density Density Content Density Comp.
946 6-3 S - 1 GRADE F 117.0 124.8 11.4 112.0 96 DOCK DOORS
947 6-3 S - 1.5 GRADE F 117.0 122.9 9.5 112.2 96 DOCK DOORS
948 6-3 S - 2.5 GRADE F 117.0 123.8 9.8 112.7 96 DOCK DOORS
949 6-3 S - 3 GRADE F 117.0 125.5 11.3 112.7 96 DOCK DOORS
950 6-3 S - 3.5 GRADE F 117.0 124.6 11.1 112.1 96 DOCK DOORS
951 6-3 S-3.8 GRADE F 117.0 124.6 10.9 112.3 96 DOCK DOORS
952 6-3 S - 4 GRADE F 117.0 127.3 10.7 114.9 98 DOCK DOORS
953 6-3 S - 5 GRADE F 117.0 127.1 10.4 115.1 98 DOCK DOORS
954 6-3 S - 5.5 GRADE F 117.0 129.6 8.9 119.0 100 DOCK DOORS
955 6-3 S - 5.8 GRAOE F 117.0 127.1 10.0 115.5 99 DOCK DOORS
956 6-3 S - 6 GRADE F 117.0 128.8 9.2 117.9 100 DOCK DOORS
957 6-3 S - 6.8 GRADE F 117.0 127.4 9.9 115.9 99 DOCK DOORS
958 6-3 S - 7 GRADE F 117.0 125.4 11.3 112.6 96 DOCK DOORS
959 6-3 S - 7.5 GRADE F 117.0 128.1 11.2 115.1 98 DOCK ODORS
960 6-3 S - 7.8 GRADE F 117.0 122.1 10.1 110.8 95 DOCK DOORS
961 6-3 S - 8 GRADE F 117.0 123.4 8.4 113.8 97 DOCK DOORS
962 6-3 S - 8.5 GRADE F 117.0 122.3 9.9 111.2 95 DOCK DOORS
963 6-9 SOUTHgEST RAMP GRADE F 117.0 123.6 11.3 111.0 95
NOTES: Densities shown: pounds per cubic foot
gater Content: Percent of dry ueight ~ brracan
Percent Compaction: Based on maximum dry density obtained on
sample indicated by material mark.