Park West CC(4)-LR 940427 (2) ] fflilcon
CONSULTANTS, INC.
"~" ~:-: .... =-' =- '::.a. 5.-.. i~-
L'.: ::~.
April 27, 1994
"-'-"'-."-
Dupey Management Corporation
9015 Sterling Street
Irving, Texas 75063
Attn: Mr. Robert McCann Re: M J Designs Distribution Center
Coppell, Texas
Job No. 17931033
Dear Mr. McCann:
A Terracon Consultants, Inc. representative has continued to perform field density testing on
compacted fills for the referenced project. This report covers the compaction testing services
performed from April 11 to April 20, 1994. Services provided during this period consisted of
performing field density tests on compacted fill placed in utility line and tilt wall panel
excavations and on parking lot subgrade. The results of the field density tests performed during
this period are attached to this report.
If you have any questions regarding this report or it's attachments, please contact this office.
Sincerely,
TERRACON CONSULTANTS, INC.
Eric J. Cleveland, P.E.
Project Engineer
EJC:kms
Attachments
Copy To: James, Harwick + Partners, Inc. Bob MooreConstruction, Inc.
Mr. Mark Wolf Mr. Phil Bell
Albert Halff & Associates, Inc. City of Coppell
Mr. Paul Rielly Mr. Larry Davis
Offices of The Terracon Companies, Inc. Geofechnical, Environmenlal and Materials Engineers
A',zc~a --Jcso:: · C. 2 :'ac:, Colc'ac'~
<ansas _e"e~a Topeka qc c~ :a I '.' m~esc:a. Sl :~u I I,-' ssc.: Ka"sas: :? I Nes'as,~ L ace" :,'~a"~
QUALITY ENGINEERING SINCE 1965
FIELD COMPACTION REPORT
Job No. ].793].033
Job Name and Location M.J. DESIGNS DISTRIBUTION ~ Date 4-27-94
Architect or Engineer JAMES, ~CK + P~, INC.
Contractor BOB 10DORE OONSTRtL'-TXON, INC.
Datum SITE DATtl4
Lift #o. Haxim~ I In-Piece In-Place
Test Date Location or Mtt. Lab DryI get gater Dry Percent Co~ents
Ho. Etev. Hark Density Density Content Density Comp.
761 4-11 K - 17 LIFT 1 C 98.5 122.2 28.3 95.2 97 EXTERIOR
gALL
762 &-11 K - 17 LIFT 2 C 98.5 120.1 27.7 94.0 95 EXTERIOR
gALL
763 4-11 K - 17 GRADE C 98.5 123.0 28.1 96.0 97 EXTERIOR
gALL
EXTERIOR
76~ 4-11 J - 17 LIFT 1 C 98.5 120.3 26.5 95.1 97 gALL
765 6-11 J - 17 LIFT 2 C 98.5 119.6 27.4 93.9 95 EXTERIOR
gALL
EXTERIOR
766 4-11 J - 17 GRADE C 98.5 121.1 26.8 95.5 9Z gALL
767 4-11 N - 17 LIFT 1 C 98.5 119.7 26.3 94.8 96 EXTERIOR
gALL
EXTERIOR
768 4-11 g - 17 LIFT 2 C 98.5 122.5 28.6 95.4 97 gALL
EXTERIOR
769 4-11 N - 17 GRADE C 98.5 119.2 28.0 93.1 95 gALL
770 6-11 G - 17 LIFT 1 C 98.5 119.9 27.3 94.2 96 EXTERIOR
gALL
771 4-11 G - 17 LIFT 2 C 98.5 121.3 25.5 96.7 98 EXTERIOR
gALL
772 4-11 G - 17 GRADE C 98.5 122.5 28.4 95.4 97 EXTERIOR
gALL
773 4-11 F - 17 LIFT 1 C 98.5 120.1 28.0 93.8 95 EXTERIOR
gALL
774 4-11 F - 17 LIFT 2 C 98.5 122.2 27.3 96.0 97 EXTERIOR
gALL
775 4-11 F - 17 GRADE C 98.5 120.0 22.0 98.4 100 EXTERIOR
gALL
776 4-11 E - 17 LIFT 1 C 98.5 119.7 26.3 94.8 96 EXTERIOR
gALL
77T 6-11 E - 17 LIFT 2 C 98.5 119.6 25.2 95.5 97 EXTERIOR
gALL
778 4-11 E ' 17 GRADE C 98.5 123.0 28.1 96.0 97 EXTERIOR
gALL
779 4-11 D - 17 LIFT 1 C 98.5 122.2 2?.3 96.0 97 EXTERIOR
gALL
780 4-11 O - 17 LIFT 2 C 98.5 120.3 26.5 95 1 97 EXTERIOR
' gALL
EXTERIOR
781 4-11 O - 17 GRADE C 98.5 119,6 27.4 93.9 95 gALL
INTERIOR
782 4-11 K - 17 LIFT 1 I 114.0 129.4 17.2 110.4 97 gALL
783 4-11 K - 17 LIFT 2 I 114.0 126.5 16.3 108.7 95 INTERIOR
gALL
78/+ 4-11 K - 17 GRADE I 116.0 128.0 16.0 110.3 97 INTERIOR
gALL
785 4-11 J - 17 LIFT 1 I 114.0 128.2 17.0 109.5 96 INTERIOR
gALL
INTERIOR
786 4-11 J - 17 LIFT 2 I 116.0 128.8 17.5 109.6 96 gALL
787 4-11 J - 17 GRADE [ 116.0 128.8 17.1 109.9 96 INTERIOR
gALL
NOTES: Densities sho~n: pounds per cubic foot
gater Content: Percent of dry geight ~ brracan
Percent Compaction: Based on maximum dry density obtained on
sample indicated by material mark.
FIELD COMPACTION REPORT
Job No. 17931033
Job Name and Location M.J. DESIGNS DISTRIBUTION CI~'TER Date 4-27-94
Architect or Engineer JAMES, HARW'I~ + P~, INC.
Contractor BOB FIOORE CE)NSTRUCTION, INC.
Datum SITE DATL~
Lift No. Haximum In-PLace In-PLace
Test Date Location or Htr. Lab Dry Wet Water Dry Percent Coarnents
No. E[ev. Hark Density Density Content Oensity Comp.
788 4-11 N - 17 LIFT 1 I 114.0 129.7 17.0 110.8 97 INTERIOR
WALL
789 4-11 H - 17 LIFT 2 I 114.0 129.4 17.3 110.3 97 INTERIOR
WALL
INTERIOR
790 4-11 H - 17 GRADE I 114.0 126.2 16.1 108.6 95 WALL
791 4-11 G - 17 LIFT 1 I 114.0 128.2 17.0 109.5 96 INTERIOR
WALL
792 4-11 G - 17 LIFT 2 I 114.0 129.3 18.3 109.2 96 INTERIOR
WALL
793 4-11 G - 17 GRADE [ 114.0 128.0 16.0 110.3 97 INTERIOR
WALL
]NTERIOR
794 4-11 F - 17 LIFT 1 ! 114.0 126.5 16.3 108.7 95 WALL
795 4-11 F - 17 LIFT 2 I 114.0 130.2 17.5 110.8 97 INTERIOR
WALL
796 4-11 F - 17 GRADE I 114.0 129.3 18.0 109.5 96 INTERIOR
WALL
INTERIOR
797 4-11 E - 17 LIFT 1 I 114.0 127.4 17.2 108.7 95 WALL
798 &-11 E - 17 LIFT 2 I 114.0 128.5 17.1 109.7 96 INTERIOR
WALL
799 4-11 E - 17 GRADE I 114.0 128.0 16.0 110.3 97 INTERIOR
WALL
800 4-11 D - 17 LIFT 1 ! 114.0 128.5 16.8 110.0 96 INTERIOR
WALL
801 4-11 D - 17 LIFT 2 I 114.0 129.3 18.0 109.5 96 INTERIOR
WALL
802 4-11 D - 17 GRADE I 114.0 128.8 17.1 109.9 96 INTERIOR
WALL
803 4-11 STATION 11 + O0 GRADE C 98.5 119.6 27.4 93.9 95 12 IN. SS
NORTH LOT
804 4-11 STATION 12 + O0 GRADE C 98.5 121.0 27.1 95.2 97 12 IN. SS
NORTH LOT
805 4-11 STATION 13 + O0 GRADE C 98.5 119.5 28.0 93.3 95 12 IN. SS
NORTH LOT
806 4-11 STATION 14 + O0 GRADE C 98.5 121.3 25.5 96.7 98 12 IN. SS
NORTH LOT
807 4-11 STATION 15 + O0 GRADE C 98.5 120.1 28.7 93.3 95 12 IN. SS
NORTH LOT
808 4-11 STATION 16 + O0 GRADE C 98.5 119.7 26.3 94.8 96 12 IN. SS
NORTH LOT
809 4-11 STATION 17 + O0 GRADE C 98.5 122.2 27.3 96.0 97 12 IN. SS
NORTH LOT
810 4-11 STATION 18 + O0 GRADE C 98.5 121.3 25.5 96.7 98 12 lg. SS
NORTH LOT
811 4-11 STATION 19 + O0 GRADE C 98.5 118.5 26.5 93.7 95 12 IN. SS
NORTH LOT
812 4-11 STATION 20 + O0 GRADE C 98.5 123.0 28.1 96.0 97 12 IN. SS
NORTN LOT
813 &-11 STATION 21 + O0 GRADE C 98.5 121.4 27.& 95.3 97 12 IN. SS
NORTH LOT
814 &-11 STATION 22 + O0 GRADE C 98.5 123.0 28.1 94.5 96 12 IN. SS
NORTH LOT
NOTES: Densities shown: pounds per cubic foot
~ater Content: Percent of dry weight ] brracan
Percent Compaction: Based on maximum dry density obtained on
sample indicated by material mark.
FIELD COMPACTION REPORT
Job No. 17931033
Job Name and Location M.J. DESIGNS DISTRIBLflq20N ~ Date 4-27-94
Architect or Engineer JAMES, ~CYK + P~, INC.
Contractor BOB MOORE CONSTRUCTION, INC.
Datum SITE ~
Lift No. Haxin~dm In-PLace In-PLace
Test Date Location or Htr. Lab Dry get gater Dry Percent Comments
No. ELev. Hark Density Density Content Density Comp.
EXTERIOR
815 4-12 C -17 LIFT 1 C 98.5 121.6 26.3 96.3 98 gALL
816 4-12 C -17 LiFT 2 C 98.5 119.5 25.1 ~5.5 97 EXTERIOR
gALL
EXTERIOR
817 4-12 C -17 GRADE C 98.5 121.3 27.2 95.4 97 gALL
EXTERIOR
818 4-12 8 -17 LIFT 1 C 98.5 120.7 24.8 96.7 98 gALL
819 &-12 B -17 LIFT 2 C 98.5 121.3 25.2 96.9 98 EXTERIOR
gALL
820 4-12 B -17 GRADE C 98.5 119.1 25.2 95.1 97 EXTERIOR
gALL
821 4-12 A -17 LIFT 1 C 98.5 121.0 26.6 95.6 97 EXTERIOR
gALL
822 4-12 A '17 LIFT 2 C 98.5 120.0 24.5 96.4 98 EXTERIOR
gALL
823 4-12 A -17 GRADE C 98.5 118.5 26.4 93.8 95 EXTERIOR
gALL
824 4-12 C -17 LIFT 1 D 114.0 125.2 16.1 107.8 95 iNTERIOR
gALL
INTERIOR
825 &-12 C - 17 LIFT 2 D 114.0 128.0 16.6 109.? 96 gALL
826 4-12 C - 17 GRADE O 114.0 125.8 15.3 109.1 96 INTERIOR
gALL
827 4-12 A - 17 LIFT 1 D 114.0 126.3 15.5 109.3 96 INTERIOR
gALL
828 4-12 A - 17 LIFT 2 O 114.0 125.7 15.0 109.3 96 INTERIOR
gALL
INTERIOR
829 4-12 A - 17 GRADE D 114.0 127.5 16.2 109.7 96 gALL
830 4-12 B - 17 LIFT 1 D 114.0 125.5 15.0 109.1 96 INTERIOR
gALL
831 4-12 B - 17 LIFT 2 D 114.0 128.0 16.3 110.0 96 INTERIOR
gALL
832 4-12 B - 17 GRADE O 114.0 128.5 15.7 111.0 97 INTERIOR
gALL
iNTERIOR
833 4-12 A - 15 LIFT 1 O 114.0 129.2 16.1 111.2 98 gALL
834 4-12 A - 15 LIFT 2 D 114.0 126.2 15.4 109.3 96 INTERIOR
gALL
835 4-12 A - 15 GRADE 0 114.0 128.0 16.5 109.8 96 INTERIOR
gALL
836 4-13 STATION 23 + O0 LIFT 1 C 98.5 121.3 25.2 96.9 98 8 IN.
SANITARY
837 4-13 STATION 23 + O0 LIFT 2 C 98.5 120.0 24.5 96.4 98 8 IN.
SANITARY
838 4-13 STATION 23 + O0 GRADE C 98.5 120.? 24.8 96.? 98 8 IN.
SANITARY
839 4-13 STATION 24 + O0 LIFT 1 C 98.5 119.5 25.0 95.6 97 8 IN.
SANITARY
840 4-13 STATION 24 + O0 LIFT 2 C 98.5 121.3 24.5 97.4 99 8 IN.
SANITARY
8~1 4-13 STATION 24 + O0 GRADE C 98.5 121.8 25.3 97.2 99 8 IN.
SANITARY
NOTES: Oensities shown: pounds per cubic foot
gater Content: Percent of dry weight I brracon
Percent Compaction: Based on maximum dry density obtained on
sample indicated by material mark.
FIELD COMPACTION REPORT
Job No. 17931033
Job Name and Location M.J. DESIGNS DISTRIBUTION ~ Date 4-27-94
Architect or Engineer JAMES, HA.Rg/ICK + P~, INC.
Contractor BOB MOORE OON~ON, INC.
Datum SITE DA_qT~
Lift No. Haximum In-Ptace In-Ptace
Test Date Location or Htr. Lab Dry Wet Water Dry Percent Comnents
No. Etev. Hark Density Density Content Density Comp.
8~2 4-13 60 FT. NORTH GRADE c 98.5 120.2 26.4 95.1 97 NORTH
60 FT. UEST PARKING
843 4-13 40 FT. NORTH GRADE C 98.5 121.0 26.6 95.6 9? NORTH
120 FT. WEST PARKING
8~4 4-13 180 FT. WEST GRADE C 98.5 119.5 25 1 95.5 97 NORTH
40 FT. NORTH ' PARKING
8~5 4-13 40 FT. NORTH GRADE C 98.5 118.6 26.2 94.0 95 NORTH
240 FT. ~EST PARKING
8~6 4-13 40 FT. NORTH GRADE C 98.5 120.1 26.5 94.9 96 NORTH
350 FT. ~EST PARKING
8~? ~-13 100 FT. NORTH GRADE C 98.5 119.5 24.8 95.8 97 NORTH
60 FT. ~EST PARKING
848 4-13 100 FT. NORTH GRADE C 98.5 121.6 26.3 96.3 98 NORTH
120 FT. WEST PARKING
8~9 4-13 100 FT. NORTH GRADE C 98.5 119.1 25.2 95.1 9? NORTH
180 FT. ~EST PARKING
850 4'13 100 FT. NORTH GRADE C 98.5 119.0 25.0 95.2 97 NORTH
240 FT. ~EST PARKING
851 &-13 100 FT. NORTH GRADE C 98.5 121.3 27.2 95.4 9? NORTH
350 FT. ~EST PARKING
852 4-13 13 - A LIFT 1 1 114.0 127.5 16.2 109.? 96 iNTERIOR
~ALL
853 &-13 13 - A LIFT 2 I 114.0 126.2 15.4 109.3 96 INTERIOR
~ALL
INTERIOR
854 4-13 13 - A GRADE ! 114.0 125.5 15.0 109.1 96 WALL
855 4-13 11 - A LIFT I I 114.0 127.0 15.5 109.9 96 INTERIOR
~ALL
856 4-13 11 - A LIFT 2 [ 114.0 129.3 16.5 110.9 97 INTERIOR
WALL
85? 4-13 11 - A GRADE I 114.0 128.8 17.0 110.0 96 INTERIOR
~ALL
858 4-14 STATION 26 + O0 LIFT 1 C 98.5 119.5 24.2 96.2 98 8 IN.
SANITARY
859 4-14 STATION 26 + O0 LIFT 2 C 98.5 121.0 25.5 96.4 98 8 IN.
SANITARY
860 4-14 STATION 26 + O0 GRADE C 98.5 118.7 24.3 95.5 97 8 IN.
SANITARY
861 4-14 STATION 28 + O0 LIFT 1 C 98.5 120.3 23.6 97.3 99 8 IN.
SANITARY
862 4-14 STATION 28 + O0 LIFT 2 C 98.5 119.0 24.1 95.9 97 8 IN.
SANITARY
863 4-14 STATION 28 + O0 GRADE C 98.5 121.3 24.8 97.2 99 8 IN.
SANITARY
86~ ~-18 20 FT - NORTH GRADE C 98.5 119.3 2~.6 95.9 97 NORTH~ST
60 FT - EAST PARKING
865 4-18 20 FT - NORTH GRADE C 98.5 120.1 25.1 96.0 97 NORTHWEST
120 FT - EAST PARKING
866 4'18 20 FT - NORTH GRADE C 98.5 118.5 24.6 95.1 97 NORTHi4EST
180 FT - EAST PARKING
867 4-18 20 FT - NORTH GRADE C 98.5 121.0 26.0 96.0 9? NORTHWEST
240 FT - EAST PARKING
868 4-18 20 FT - NORTH GRADE C 98.5 119.8 25.3 95.6 9? NORTHWEST
300 FT - EAST PARKING
NOTES: Densities shoun: pounds per cubic foot
Water Content: Percent of dry weight I brracan
Percent Compactfon: Based on maximum dry density obtained on
sampte indicated by materiat mark.
FIELD COMPACTION REPORT
Job No. 17931033
Job Name and Location M.J. DESIGHS DISTRXBUTXOH ~ Date 4-27-94
Architect or Engineer JAP[F_~,
Contractor BOB lvIOORE OD~ISTRUC'i~OH~ l'lqC.
Datum $1TE DATt~
Lift No. Haximum In-PLace in-Place
Test Date Location or Ht[. Lab Dry get gate? Dry Percent Co~me~ts
Ho. E[ev. Hark Oensity Density Content Density Comp,
869 4-18 80 FT - NORTH GRADE C 98.5 119.2 24.0 96.1 98 NORTHgEST
60 FT - EAST PARKING
870 4-18 80 FT - NORTH GRADE C 98.5 119.0 24.0 96.0 97 NORTH~ST
120 FT - EAST PARKING
871 &-18 80 FT - NORTH GRADE C 98.5 121.5 26.2 96.3 98 NORTHgEST
180 FT - EAST PARKING
872 6-18 80 FT - NORTH GRADE C 98.5 119.8 25.5 95.5 97 NORTNgEST
240 FT - EAST PARKING
873 6-18 80 FT - NORTH GRADE C 98.5 120.3 24.3 96.8 98 NORTflgEST
300 FT - EAST PARKING
8?6 4-18 D - 1OR LIFT 1 I 114.0 127.5 16.2 109.? 96 IHTERNAL
gALL
875 6-18 D - 1OR LIFT 2 I 114.0 126.3 15.5 109.3 96 INTERNAL
gALL
876 6-18 D - 1OR GRADE I 114.0 125.2 16.1 107.8 95 INTERNAL
WALL
877 6-18 H - 1OR LIFT 1 I 116.0 128.0 16.5 109.8 96 INTERNAL
gALL
878 6-18 H - 1OR LIFT 2 I 116.0 125.5 15.6 108.5 95 INTERNAL
gALL
879 4-18 H - 1OR GRADE I 114.0 126.8 16.2 109.1 96 INTERNAL
gALL
880 4-18 H - 1OR LIFT 1 I 114.0 128.5 15.3 111.4 98 INTERNAL
gALL
881 6-18 M - 1OR LIFT 2 ! 114.0 12?.3 16.0 109.7 96 INTERNAL
gALL
882 6-18 M - 1OR GRADE ! 114.0 125.5 15.3 108.8 95 INTERNAL
gALL
883 4-18 R - 1OR LIFT 1 I 114.0 126.0 14.8 109.7 96 INTERHAL
gALL
88/, 6-18 R - 1OR LIFT 2 I 114.0 127.7 15.5 110.5 9? IHTERHAL
WALL
885 6-18 R - 1OR GRADE I 114.0 126.3 14.5 110.3 9? INTERNAL
gALL
886 6-20 R - 10~ LIFT 1 I 114.0 126.3 15.3 109.5 96 INTERNAL
gALL
887 6-20 R - lOg LIFT 2 I 114.0 128.0 15.0 111.3 98 INTERNAL
gALL
888 6-20 M - log LIFT 1 ] 116.0 126.0 15.8 108.8 95 INTERNAL
gALL
889 6-20 M - lOB LIFT 2 I 114.0 127.5 16.3 109.6 96 INTERNAL
gALL
890 6-20 H - lOg LIFT 1 I 114.0 127.0 15.0 110.6 9r INTERNAL
gALL
891 6-20 H - log LIFT 2 I 116.0 127.6 15.8 110.1 97 INTERNAL
gALL
892 6-20 0 - IOU LIFT 1 I 116.0 129.3 15.5 111.9 98 INTERNAL
gALL
893 6-20 D - IOU LIFT 2 I 116.0 128.0 16.1 110.2 97 INTERNAL
gALL
NOTES: Densities sho~n: pounds per cubic foot
gater Content: Percent of dr'y ~leight 1 rracan
Percent Compaction: Based on maximum dry density obtained on
sample indicated by material mark.