Park West CC(4)-LR 940418 f£ con
CONSULTANTS, INC.
__'-: '-:~:. ::':.i~-'
April 18, 1994 ::,...~.~: .....
_~' ....:
Dupey Management Corporation
9015 Sterling Street
Irving, Texas 75063
Attn: Mr. Robert McCann Re: M J Designs Distribution Center
Coppell, Texas
Job No. 17931033
Dear Mr. McCann:
A Terracon Consultants, Inc. representative has continued to perform field density testing on
compacted fills for the referenced project. This report covers the compaction testing services
performed from March 24 to April 8, 1994. Services provided during this period consisted of
performing field density tests on compacted fill placed in utility line and tilt wall panel
excavations and on parking lot subgrade. The results of the field density tests performed during
this period along with two moisture-density relationship tests performed on materials used as fill
are attached to this report.
If you have any questions regarding this report or it's attachments, please contact this office.
Sincerely,
TERRACON CONSULTANTS~ INC.
Eric J. Cleveland, P.E.
Project Engineer
EJC:kms
Attachments
Copy To: James, Harwick + Partners, Inc. Bob Moore Construction, Inc.
Mr. Mark Wolf Mr. Phil Bell
Albert Halff & Associates, Inc. City of Coppell
Mr. Paul Rielly Mr. Larry Davis
Olfices ol The Terracon Companies, Inc. Geotechnical, Environmenlal and Materials Engineers
O~ aqc~a C< ahs. ma C :y T¢ sa I Te,as Dal as I L:a". Sil: _aCe C :? I ',';'yg.,-~.-~ Cr.E...em-e
QUALITY ENGINEERING SINCE 1965
FIELD COMPACTION REPORT
Job No. 17931033
Job Name and Location M.J. DESIGNS DISTRIB%H~ON ~ Date 4-18-94
Architect or Engineer O--/X_l~, ~CK + P/~q-1~, ~lC.
Contractor BOB PlDORE (X~~GN, XNC.
Datum SITE DATt~
Lift No. #aximu~ In-Place In-Ptace
Teat Date Location or Mt[. Lab Dry Wet Water Dry Percent Comments
No. Etev. Hark Density Density Content Density Comp.
661 3-24 STATION 4 + 50 LIFT 1 C 98.5 121.5 29.2 94.0 95 10 IN. WATER
S. PARKING
662 3-24 STATION 4 + 50 LIFT 2 C 98.5 120.9 27.0 95.2 97 10 IN. WATER
S. PARKING
663 3-24 STATION 4 + 50 GRADE C 98.5 121.7 29.0 94.3 96 10 IN. WATER
S. PARKING
666 3-24 STATION 3 + 50 LIFT 1 C 98.5 121 1 27.6 94.9 96 10 IN. WATER
' S. PARKING
665 3-24 STATION 3 + 50 LIFT 2 C 98.5 120.6 26.3 95.5 97 10 IN. WATER
S. PARKING
666 3-24 STATION 3 + 50 GRADE C 98.5 121.0 26.4 95.7 97 10 IN. WATER
S. PARKING
667 3-24 STATION 2 + 50 LIFT 1 C 98.5 121.5 25.5 96.8 98 10 IN. WATER
S. PARKING
668 3-24 STATION 2 + 50 LIFT 2 C 98.5 120.8 27.0 95.1 97 10 IN. WATER
S. PARKING
669 3-24 STATION 2 + 50 GRADE C 98.5 121.8 26.5 96.3 98 10 IN. WATER
S. PARKING
670 3-24 STATION 1 + O0 LIFT 1 C 98.5 120.4 26.2 95.4 97 10 IN. WATER
S. PARKING
671 3-24 STATION 1 + O0 LIFT 2 C 98.5 121.2 26.9 95.5 97 10 IN. WATER
S. PARKING
672 3-24 STATION I + O0 GRAOE C 98.5 119.0 25.9 94.5 96 10 IN. WATER
S. PARKING
673 3-28 100 - N GRADE C 98.5 118.3 26.4 93.6 95 EAST PARKING
50 - W FROM SE CURB
674 3-28 200 - N GRADE C 98.5 119.0 29.5 91.9 93 EAST PARKING
50 - W FROH SE CURB
675 3-28 300 - N GRADE C 98.5 120.6 29.6 93.1 94 EAST PARKING
50 - W FROM SE CURB
676 3-28 RETEST 674 GRADE C 98.5 121.0 29.8 93.2 95 EAST PARKING
FROM SE CURB
677 3-28 RETEST 675 GRADE C 98.5 120.1 29.0 93.1 95 EAST PARKING
FROM SE CURB
678 3-28 600 - N GRADE C 98.5 118.5 29.0 91.9 93 EAST PARKING
50 - W FROM SE CURB
679 3-28 RETEST 678 GRADE C 98.5 120.7 29.1 93.5 95 EAST PARKING
FROM SE CURB
680 3-28 800 - N GRADE C 98.5 120.0 27.0 94.5 96 EAST PARKING
50 - W FROM SE CURB
681 3-28 100 - N GRADE C 98.5 120.1 26.7 94.8 96 EAST PARKING
100 - W FROM SE CURB
682 3-28 200 - N GRADE C 98.5 118.8 26.8 93.7 95 EAST PARKING
100 - W FROM SE CURB
683 3-28 300 - N GRADE C 98.5 120.5 29.2 93.3 95 EAST PARKING
100 W FROM SE CURB
68~ 3-28 400 - N GRADE C 98.5 121.3 27.5 95.1 97 EAST PARKING
100 - W FROM SE CURB
685 3-28 500 - N GRADE C 98.5 119.3 26.8 94.1 96 EAST PARKING
100 - W FROM SE CURB
686 3-28 600 - N GRADE C 98.5 120.1 27.0 94.6 96 EAST PARKING
100 - W FROM SE CURB
687 3-28 700 - N GRADE C 98.5 119.9 27.1 94.3 96 EAST PARKING
100 - W FROM SE CURB
NOTES: Densities sho~n: pounds per cubic foot
Water Content: Percent of dry weight ] brracan
Percent Conq~action: Based on maxinue dry density obtained on
sample indicated by material mark.
FIELD COMPACTION REPORT
Job No. 17931.033
Job Name and Location M.J. DESIGNS DIS'TRIBUI'ION CENTER Date 4-18-94
Architect or Engineer JAMES, HAISqICK + PARIIqlS~, INC.
Contractor BOB MOORE (X)N~ON, INC.
Datum SITE DATt~I
Lift No. Haxinte In-PLace In-Ptace
Test Date Location or Htl. Lab Dry Wet Water Dry Percent Cmements
No. Etev. Hark Density Oensity Content Density Comp.
800 - N GRADE C 98.5 119.5 28.0 93.3 95 EAST PARKING
688 3-28 100 - ~ FROH SE CURB
689 4-1 70 FT WEST GRADE C 98.5 120.2 29.0 93.2 95 EAST PARKING
80 FT NORTH FRCM SE CURB
140 FT WEST GRADE C 98.5 120.8 28.4 94.1 96 EAST PARKING
690 4-1 80 FT NORT FRDH SE CURB
691 4-1 210 FT bEST GRADE C 98.5 120.0 28.0 93.8 95 EAST PARKING
80 FT NORTH FROM SE CURB
692 4-1 280 FT WEST GRADE C 98.5 120.4 28.8 93.5 95 EAST PARKING
80 FT NORTH FROM SE CURB
693 4-1 350 FT WEST GRADE C 98.5 120.1 28.5 93.5 95 EAST PARKING
80 FT NORTH FROM SE CURB
70 FT WEST GRADE C 98.5 120.1 28.0 93.8 95 EAST PARKING
694 4-1 40 FT NORTH FROM SE CRUB
140 FT ~EST GRADE C 98.5 119.5 28.5 93.0 94 EAST PARKING
695 4-1 40 FT NORTH FROM SE CURB
210 FT WEST GRADE C 98.5 119.0 28.1 92.9 94 EAST PARKING
696 4-1 40 FT NORTH FROM SE CURB
280 FT WEST GRADE C 98.5 120.4 27.7 94.3 96 EAST PARKING
697 4-1 40 FT NORTH FROM SE CURB
698 4-1 350 FT 9EST GRADE C 98.5 120.1 28.4 93.5 95 EAST PARKING
40 FT NORTH FROM SE CURB
70 FT WEST GRADE C 98.5 120.6 26.4 95.4 97 WEST PARKING
699 4-6 40 FT SOUTH FROM NE CURB
700 4-6 140 FT NEST GRADE C 98.5 119.3 28.0 93.2 95 bEST PARKING
40 FT SOUTH FROM NE CURB
701 4-6 210 FT bEST GRADE C 98.5 120.0 27.5 94.1 96 WEST PARKING
40 FT SOUTH FROM NE CURB
702 4-6 280 FT WEST GRADE C 98.5 119.0 27.3 93.5 95 WEST PARKING
40 FT SOUTH FROM NE CURB
?03 4-6 350 FT WEST GRADE C 98.5 120.6 27.6 94.5 96 WEST PARKING
40 FT SOUTH FROM NE CURB
?04 4-6 ?0 FT UEST GRADE C 98.5 121.2 29.2 93.8 95 WEST PARKING
100 FT SOUTH FROM NE CURB
705 4-6 140 FT bEST GRADE C 98.5 119.5 27.1 94.0 95 WEST PARKING
100 FT SOUTH FROM NE CURB
706 4-6 210 FT WEST GRADE C 98.5 120.8 28.8 93.8 95 VEST PARKING
100 FT SOUTH FROM NE CURB
707 4-6 280 FT WEST GRADE C 98.5 121.0 28.0 94.5 96 WEST PARKING
100 FT SOUTH FROM NE CURB
708 4-6 350 FT WEST GRADE C 98.5 119.5 27.5 93.7 95 WEST PARKING
100 FT SOUTH FROM NE CURB
709 4-7 STATION 1 + O0 GRADE C 98.5 120.5 25.1 96.3 98 12 INCH
SANITATION
12 INCH
710 4-7 STATION 2 + O0 GRADE C 98.5 118.2 26.0 93.8 95 SANITATION
711 4-7 STATION 3 + O0 GRADE C 98.5 121.0 25.0 96.8 98 12 INCH
SANITATION
712 4-7 STATION 4 + O0 GRADE C 98.5 119.8 26.6 94.6 96 12 INCH
SANITATION
713 4-7 STATION 5 + O0 GRADE C 98.5 120.3 25.5 95.8 97 12 INCH
SANITATION
714 4-7 STATION 6 + O0 GRADE C 98.5 119.9 25.4 95.6 97 12 iNCH
SANITATION
NOTES: Densities shoun: pounds per cubic foot lbrracan
Water Content: Percent of dry ueight
Percent Compaction: Based on maximt~ dry density obtained on
sample indicated bymaterial mark.
FIELD COMPACTION REPORT
Job No. 17931033
Job Name and Location M.J. DESIGNS DISTRIBUTI~ ~ Date 4-18-94
Architect or Engineer JAMES, ~CK + P~, INC.
Contractor BOB FIDORE OONSTRLL-TION, INC.
Datum SITE ~
Lift No. Haximu~ In-PLace In-PLace
Teat Date Location or Htt. Lab Dry get gater Dry Percent Coanents
No. Etev. Hark Density Density Content Density Comp.
715 6-7 STATIOM 7 + O0 GRADE C 98.5 120.0 25.7 95.5 97 12 INCH
SANITATION
716 6-7 STATION 8 + O0 GRADE C 98.5 119.& 26.0 96.8 96 12 INCH
SANITATION
717 &-7 STATION 9 + O0 GRADE C 98.5 120.9 28.3 94.2 96 12 INCH
SANITATION
718 4-7 STATION 10 + O0 GRADE C 98.5 119.6 25.4 95.2 97 12 INCH
SANITATION
719 6-8 S - LINE LIFT 1 I 114.0 128.2 17.1 109.4 96 INTERIOR
gALL
INTERIOR
720 6-8 S - LINE LIFT 2 I 116.0 128.5 16.8 110.0 96 gALL
721 6-8 S - LINE GRADE [ 116.0 128.2 17.0 109.5 96 INTERIOR
gALL
722 6-8 R - LINE LIFT 1 ! 116.0 126.6 17.3 107.9 95 INTERIOR
gALL
723 6-8 R - LINE LIFT 2 [ 116.0 129.3 18.3 109.2 96 INTERIOR
gALL
726 6-8 R - LINE GRADE I 116.0 128.5 17.1 109.7 96 INTERIOR
gALL
725 6-8 Q - LINE LIFT 1 ! 116.0 129.8 16.5 111.6 98 INTERIOR
gALL
726 6-8 Q - LINE LIFT 2 ! 116.0 128.0 16.0 110.3 97 INTERIOR
gALL
?27 4-8 Q - LINE GRADE I 114.0 127.4 17.2 108.7 95 INTERIOR
gALL
?28 4-8 P - LINE LIFT 1 I 114.0 129.5 17.5 110.2 9? INTERIOR
gALL
729 4-8 P - LINE LIFT 2 I 114.0 128.8 17.1 109.9 96 INTERIOR
gALL
7'30 6-8 P - LINE GRADE ! 114.0 126.5 16.3 108.7 95 INTERIOR
gALL
731 4-8 g - LINE LIFT 1 I 114.0 129.6 1?.2 110.6 9r INTERIOR
gALL
732 6-8 g - LINE LIFT 2 I 116.0 131.6 17.7 111.8 98 INTERIOR
gALL
733 6-8 N - LINE GRAOE ! 116.0 129.3 18.0 109.5 96 INTERIOR
gALL
736 6-8 H - LINE LIFT 1 I 116.0 127.5 17.3 108.6 95 INTERIOR
gALL
735 4-8 H - LINE LIFT 2 I 116.0 128.3 17.0 109.6 96 INTERIOR
gALL
736 6-8 H - LINE GRADE I 114.0 130.2 17.5 110.8 97 INTERIOR
gALL
INTERIOR
737 4-8 L - LINE LIFT I i 116.0 129.6 17.3 110.3 97 gALL
738 6-8 L - LINE LIFT 2 I 116.0 128.8 17.5 109.6 96 INTERIOR
gALL
739 4-8 L - LINE GRADE I 116.0 129.7 17.0 110.8 97 INTERIOR
gALL
760 4-8 S - LINE LIFT 1 C 98.5 121.3 28.1 96.7 96 EXTERIOR
gALL
741 4-8 S - LINE LIFT 2 C 98.5 120.5 28.0 94.1 96 EXTERIOR
gALL
NOTES: Densities sho~n: pounds per cubic foot
gate? Content: Percent of dry weight ~ brracan
Percent Compaction: Based on eaximtaadry density obtained on
sample indicatedbymateriat mark.
FIELD COMPACTION REPORT
Job No. 3.7931033
Job Name and Location M.J. DESIGNS DI~ON ~ Date 4-18-94
Architect or Engineer JAMES, HA_g$~C~ + P~, INC.
Contractor _ BOB MOORE CONgi'RI. ETION, INC.
Datum SITE ~
Lift No. Haxinu~ In-Ptace In-PLace
Test Date Location or HtL. Lab Dry get gater Dry Percent Con~ents
No. ELev. Hark Density Density Content Density Comp.
742 4-8 S - LINE GRADE C 98.5 120.3 27.3 9&.5 96 EXTERIOR
gALL
763 6-8 R - LINE LIFT 1 C 98.5 119.6 28.2 93.1 95 EXTERIOR
gALL
766 6-8 R - LINE LIFT Z C 98.5 119.9 27.5 96.0 95 EXTERIOR
gALL
765 4-8 R - LINE GRADE C 98.5 119.6 25.2 95.5 9r EXTERIOR
gALL
766 6-8 Q - LINE LIFT 1 C 98.5 121.1 29.5 93.5 95 EXTERIOR
gALL
EXTERIOR
747 6-8 Q - LINE LIFT 2 C 98.5 120.1 27.7 96.0 95 gALL
EXTERIOR
768 4-8 Q - LINE GRADE C 98.5 121.6 2?.4 95.3 97 gALL
749 6-8 P - LINE LIFT 1 C 98.5 119.0 27.0 93.7 95 EXTERIOR
gALL
750 6-8 P - LINE LIFT 2 C 98.5 120.3 26.5 95.1 97 EXTERIOR
gALL
751 6-8 P - LINE GRADE C 98.5 122.0 27.0 96.1 98 EXTERIOR
gALL
732 6-8 N - LINE LIFT I C 98.5 119.7 26.3 96.8 96 EXTERIOR
gALL
753 4-8 N - LINE LIFT 2 C 98.5 122.5 28.4 95.6 97 EXTERIOR
gALL
EXTERIOR
754 6-8 N - LINE GRADE C 98.5 119.6 27.4 93.9 95 gALL
755 6-8 M - LINE LIFT 1 C 98.5 121.3 25.5 96.7 98 EXTERIOR
gALL
756 4-8 N - LINE LIFT 2 C 98.5 121.1 26.8 95.5 97 EXTERIOR
gALL
757 6-8 # - LINE GRADE C 98.5 121.1 28.1 96.5 96 EXTERIOR
gALL
758 4~8 L - LINE LIFT 1 C 98.5 120.6 27.5 94.6 96 EXTERIOR
gALL
759 6-8 L - LINE LIFT 2 C 98.5 119.9 27.3 96.2 96 EXTERIOR
gALL
760 4-8 L - LINE GRADE C 98.5 119.2 28.0 93.1 95 EXTERIOR
gALL
NOTES: Densities shoun: pounds per cubic foot
gater Content: Percent of dry Height I brracan
Percent Compaction: Based on maxin~m dry density obtained on
sample indicated by mater~aL mark.
· ll'erracan
135
MOISTUR~DENS1TY RELATIONSHIP
~- Job No. 17931033 Date
%,
~o Project MJ DESIGNS DISTRIBUTION
CENTER - COPPELL. TEXAS
~ Source of Material OFF SITE BORROW
Description of Material TAN SANDY CI.AY
120 ~ Material Designation H
Test Method ASTM !~-698 LMETHOD A,)
lis ~' TEST RESULTS
o Maximum Dry Density 112.5 PCF
o
Optimum Water Content
o 110
o / ATTERBERG LIMITS
~- I05 LL PL PI
~ ~ 32 15 17
o
'-~ CURVES OF 100% SATURATION
100 FOR SPECIFIC GRAVITY EQUAL TO:
>- 95
n., .60
9O
85
8O
75
0 5 10 15 20 25 30 35 40 45
NRTER CONTENT (Percent Org Height)
· 'll'erracan
135 ~ ' MOISTURE-DENSITY RELATIONSHIP
Job No. 17931033 Date 416194
130 I Project MJ DESIGNS DISTRIBUTION
CENTER - COPPELL. TEXAS
~ Source of Material OFF SITE BORROW
,zs ~ ~~ Description of Material REDDI,~;H RROWN SANDY
__ ~ CLAY
, I Material Designation I
115120 ~~~ Test Method ASTM D-698 O~ETIIOD A)
c- ~ TEST RESULTS
o Maximum Dry Density 114.0 PCF
o
Optimum Water Content 14.5 %
'-' ATTERBERG LIMITS
o. 10s LL PL PI
'o 28 14 14
o
v CURVES OF 100% SATURATION
100 FOR SPECIFIC GRAVITY EQUAL TO:
~= 95
r~ -- 2.60
90
85
80
75
0 5 10 15 20 25 30 35 40 45
NRTER CONTENT (Percent Dr~J Neight)