ST9801-LR000802 (2) 9200 King Arthur Ddve Dallas, Texas 75247-3610 Phone 214/631-4372 Fax 214,~631-4380 CONCRETE COMPRESSION TEST REPORT Report No.: Location: Project: Contractor: Reported To: 93 Job No.: Box Culvert from Sta. 3+29 to 3+41 Coppell Road Paving and Drainage Improvements Ed Bell Construction City of Coppell - Kenneth Griffin, P.E. (6 x 12 Inch) Nominal Cylinder Size: Area - 28.27 SQ. IN. Field Number: Test Date: Maximum Load, LBS: Age When Tested, Days: Compresslye Strength, PSh Average Strength, PSh Type Break: Conical (U.N.O.) Remarks: 1520COP03 Date Cast: Specification: Quantity Represented: Sampled By: By Order Of: CP080201 CP080202 CP080203 08/09~0 08/30/00 08/30/00 76390 109170 99060 7 28 28 2700 3860 3500 3680 08/02/00 3500 psi @ 28 days 10 of 50 M. Kashem CP080204 DISCARD DISCARD Temperature: Ambient Time of Sample: Source of Concrete: 88 ° F 10:55 AM Pioneer - 9339 Mix 90 ° F Air Content N/A % Slump Pick-Up Charge: Yes N/A Ticket No.: 675412 5.00 Inches Fine Aggregate: Coarse Aggregate: Water: Cement: Fly Ash.: Admixture(s): Distribution: City of Coppell - Larry Davis Unit Weight PCF Yield CF/CY Test Methods: ASTM C 31, C 39, C 173, C 192, C 231 and C 1064 OUR LE'I'I'ERS AND REPORTS ARE FOR THE EXCLUSIVE USE OF THE CLIENT TO WHOM THEY ARE ADDRESSED AND APPLY ONLY TO THE SAMPLES TESTED, TEST RESULTS ARE NOT NECESSARILY INDICATIVE OF THE QUALITY OF APPARENTLY IDENTICAL OR SIMILAR SAMPLES. THIS REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL W1THOUT THE APPROVAL OF STANTECH.