Park West CC(12)-LR010314 GEOTECHNICAL AND
ENVIRONHENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
Parkwest Commerce Center - Building 4
Enterprise Drive at Wrangler Drive
Coppell, Texas
REPORTED TO:
REPORT NO. 28
REG PROJECT NO. 4772
SAMPLE DATE: 03-14-01
TECHNICIAN: A. Chairez
Pritchard Associates
2501 State Street
Dallas, Texas 75201
A'FI'N: Mr. Roger Dahlin
CONTRACTOR: McFadden & Miller, Inc.
Location of Sample
I set Number I L°cati°n21 PaneIPanel ## 2310 J Quantity Represented1230/35060/350
Design Information
Set Number Concrete Mix Identification Specified Strength p.s.i.
1 TXI 46 3000
Test Results
Set Cylinder I Age @ Total Load Compressive I Average Strength
No. ID I Date Tested Test lbs. Strength p.s.i. I p.s.i.
1 4632 03-21-01 7 88560 3130
4632 04-11-01 28 138340 4900
4632 04-11-01 28 144540 5120 5010
4632 Hold H
2 4633 03-21-01 7 98680 3490
4633 04-11-01 28 143730 5090
4633 04-11-01 28 146280 5180
4633 Hold H
5140
Cylinder Data
JSet I Cylinder J J Concrete AirI
No. I ID Slump Air Temp. Temp. Entrainment
4632 6.00 9:00AM 59 65
4633 6.00 11:00AM 65 65
Time of J Ticket
SampleJ Number
N/A 2840027
N/A 2840146
Distribution:
(1) Pritchard Associates/
Mr. Roger Dahlin
(1) O'Brien & Associates/
Mr. Mick Granlund
(1) Technistructures/Mr. Keith Leslie
(1) McFadden & Miller/
Mr. Jon Jacobsen
(1) Halff Associates/Mr. Dave Littleton
(1) City of Coppell/Mr. Larry Davis
(1) City of Coppell/Mr. Lee Stone
Submitted by:
REED ENGINEERING GROUP, INC.
Original Signed By
Keith E. Atkins
KENje
2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEl. [214] 350 5600 · FAX [214] 350 0019
GEOTECHNICALAND J ~ ~ r'"'l I I F:~
ENVIRON~tENTAL CONSULTANTS
I
CONCRETE CYLINDER TEST REPORT
Parkwest Commerce Center - Building 4
Enterprise Drive at Wrangler Drive
Coppell, Texas
REPORTED TO:
CONTRACTOR:
Pritchard Associates
2501 State Street
Dallas, Texas 75201
ATTN: Mr. Roger Dahlin
McFadden & Miller, Inc.
REPORT NO. 28
REG PROJECT NO. 4772
SAMPLE DATE: 03-14-01
TECHNICIAN: A. Chairez
Location of Sample
I set Number I L°cati°n21 PaneIPanel ## 2310 I Quantity Represented1230/35060/350
Design Information
Set Number Concrete Mix Identification Specified Strength p.s.i.
1 TXI 46 3000
Test Results
Set Cylinder J
No. ID Date Tested
1 4632 03-21-01
4632 04-11-01
4632 04-11-01
4632 Hold
J Age@ ITotalLoad J Compressive
Test lbs. Strength p.s.i.
7
28
28
H
88560 3130
2 4633 03-21-01 7 98680
4633 04-11-01 28
4633 04-11-01 28
4633 Hold H
349O
J Average Strength
p.s.h
Cylinder Data
Set Cylinder
I 4632 6.00 9:00AM
2 4633 6.00 11:00AM
Concrete Air Time of Ticket
Temp. Entrainment Sample Number
59 65
65 65
N/A 2840027
N/A 2840146
Distribution:
(1) Pritchard Associates/
Mr. Roger Dahlin
(1) O'Brien & Associates/
Mr. Mick Granlund
(1) Technistructures/Mr. Keith Leslie
(1) McFadden & Milled
Mr. Jon Jacobson
(1) Halff Associates/Mr. Dave Littleton
(1) City of Coppell/Mr. Larry Davis
(1) City of Coppell/Mr. Lee Stone
Submitted by:
REED ENGINEERING GROUP, INC.
Original Signed By
Keith E. Atkins
KENje
2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 o FAX [214] 350 0019