Park West CC(12)-LR010614GEOTECNNICAL AND ~ J=::JJ r-",l J_,J ~
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
Parkwest Commerce Center - Building 5
Enterprise and Wrangler
Coppell, Texas
REPORTED TO:
Pritchard Associates
2501 State Street
Dallas, Texas 75201
ATTN: Mr. Roger Dahlin
CONTRACTOR: McFadden & Miller
Location of Sample
JSet Number J Location
1 Paving: 200'S, 25'E of N.E. building corner
REPORT NO. 39
REG PROJECT NO. 7479
SAMPLE DATE: 06-14-01
TECHNICIAN: M. Silva
J Quantity Represented
30/40
Design Information
Is°urce °f c°ncrete ITXI Mix Identification 8273 I Specified Strength P's'i' I 4000
Test Results
Set Cylinder
No. ID Date Tested
Age @ J Total Load Compressive Average
Test I lbs. Strength p.s.i. Strength p.s.i.
1 9197 06-21-01 7 81800 2890
9197 07-12-01 28 122540 4340
9197 07-12-01 28 126620 4480 4410
Cylinder Data
Set1 Cylinder Time of I I Concrete Air Ticket I
No. ID Slump Sample Air Temp. Temp. Entrainment Number
9197 5.50 7:55AM 80 88 N/A 2915526
Mail
Distribution:
(1) Pritchard Associates/
Mr. Roger Dahlin
(1) O'Brien & Associates/
Mr. Mick Granlund
(1) Technistructures/Mr. Keith Leslie
(1) McFadden & Miller, Inc./
Mr. Jon Jacobson
(1) Halff Associates/Mr. Dave Littleton
(1) City of Coppell/Mr. Larry Davis
(1) City of Coppell/Mr. Lee Stone
Submitted by:
REED ENGINEERING GROUP, INC.
Original Signed By
Keith E. Atkins
KEA/je
2424 STUTZ DR. · SUITE 400 · DALLAS, 235 · TEL [214] 350 5600 · FAX [214] 350 0019
GEOTECHNICAL AND I~ F=I r-1 I._.1 F:a
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
Parkwest Commerce Center - Building 5
Enterprise and Wrangler
Coppell, Texas
REPORTED TO:
Pritchard Associates
2501 State Street
Dallas, Texas 75201
ATTN: Mr. Roger Dahlin
CONTRACTOR: McFadden & Miller
Location of Sample
Set Number J Location
REPORT NO. 39
REG PROJECT NO. 7479
SAMPLE DATE: 06-14-01
TECHNICIAN: M. Silva
J Quantity Represented
1 Paving: 200'S, 25'E of N.E. building corner 30/40
Design Information
I Source of Concrete I Mix Identification I Specified Strength p.s.i.
TXI 8273, 4000
Test Results
Set Cylinder
No. ID
1 9197
9197
9197
Age@ Total Load I CompressiveI Average
Date Tested Test lbs. Strength p.s.i. Strength p.s.i.
06-21-01 7
07-12-01 28
07-12-01 28
81800 2890
Cylinder Data
Set Cylinder
N~3. ID
9197
Time of
Slump Sample
I Concrete Air Ticket
Air Temp. Temp. Entrainment Number
5.50 7:55AM 80
88 N/A 2915526
Mail
Distribution:
(1) Pritchard Associates/
Mr. Roger Dahlin
(1) O'Brien & Associates/
Mr. Mick Granlund
(1) Technistructures/Mr. Keith Leslie
(1) McFadden & Miller, Inc./
Mr. Jon Jacobson
(1) Halff Associates/Mr. Dave Littleton
(1) City of Coppell/Mr. Larry Davis
(1) City of Coppell/Mr. Lee Stone
Submitted by:
REED ENGINEERING GROUP, INC.
Original Signed By
Keith E. Atkins
KEA/je
2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 * TEL [214] 350 5600 · FAX [214] 350 0019