Park West CC(12)-LR010613GEOTECHNICAL AND G J:==J r--i U ~
ENVIRONMENTAL CONSULTANTS
REPORT OF SIEVE ANALYSIS
Parkwest Commerce Center - Building 5
Enterprise and Wrangler
Coppell, Texas
REPORTED TO:
Pritchard Associates
2501 State Street
Dallas, Texas 75201
ATTN: Mr. Roger Dahlin
CONTRACTOR: McFadden & Miller
REPORT NO. 30
REPORT DATE: 06-13-01
REG PROJECT NO. 7479
TECHNICIAN: C. McEntee
PAGE: 1 of 1
Material Description: Pea gravel
Proposed Usage: Roof ballast
Reference Standard: ASTM D-1863
Size 67A
U.S. Std. J Cumulative
Sieve Size J Percent Passing
Specification
Percent Finer
1" 100 100
3/4" 1 O0 90-1 O0
3/8" 38 20-55
No. 4 1 0-10
No. 8 0 0-5
The sample conforms to the referenced specifications.
Mail
Distribution: (1)
Pritchard Associates/
Mr. Roger Dahlin
(1) O'Brien & Associates/
Mr. Mick Oranlund
(1) Technistructures/Mr. Keith Leslie
(1) McFadden & Miller, Inc./
Mr. Jon Jacobson
(1) Halff Associates/Mr. Dave Littleton
(1) City of Coppell/Mr. Larry Davis
(1) City of Coppell/Mr. Lee Stone
Submitted by:
REED ENGINEERING GROUP, INC.
Original Signed By
James F. Phipps, P.E.
KA/cg
2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019