Loading...
Park West CC(12)-LR010423GEOTECHNICAL AND J J~J R r--i U ~ I:NVIRONHENTAL CONSULTANTS CONCRETE CYLINDER TEST REPORT Parkwest Commerce Center - Building 5 Enterprise and Wrangler Coppell, Texas REPORTED TO: Pritchard Associates 2501 State Street Dallas, Texas 75201 ATTN: Mr. Roger Dahlin REPORT NO. 25 REG PROJECT NO. 7479 SAMPLE DATE: 04-23-01 TECHNICIAN: B. Steadman McFadden & Miller CONTRACTOR: Location of Sample Set Number J Location J Quantity Represented J 1 Piers: A.1-1.1, A.1-6, A.2-1.2, A.2-5.7 and A.2-6.3 20~20 I Design Information Source of Concrete J Mix Identification I Specified Strength p.s.i. J TXI 19 3000 I Test Results Set Cylinder J No. ID Age@ TotalLoad J Compressive J Average Date Tested Test lbs. Strength p.s.i. Strength p.s.i. 6413 04-30-01 7 6413 05-21-01 28 6413 05-21-01 28 91570 3240 Cylinder Data Set Cylinder I Timeof I Nlo. ID Slump Sample Air Temp. 6413 5.50 2:45PM 68 Concrete J Air J Ticket Temp. Entrainment Number 74 N/A 2869956 Mail Distribution: (1) Pritchard Associates/ Mr. Roger Dahlin (1) O'Brien & Associates/ Mr. Mick Granlund (1) Technistructures/Mr. Keith Leslie (1) McFadden & Miller, Inc./ Mr. Jon Jacobson (1) Halff Associates/Mr. Dave Littleton (1) City of Coppell/Mr. Larry Davis (1) City of Coppell/Mr. Lee Stone Submitted by: REED ENGINEERING GROUP, INC. Original Signed By Keith E. Atkins KEA/je 2424 STUTZ DR, · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019 GEOTECHNICAL AND I~ F=I O U F=~ ENVIRONMENTAL CONSULTANTS CONCRETE CYLINDER TEST REPORT Parkwest Commerce Center - Building 5 Enterprise and Wrangler Coppell, Texas REPORTED TO: Pritchard Associates 2501 State Street Dallas, Texas 75201 ATTN: Mr. Roger Dahlin CONTRACTOR: McFadden & Miller Location of Sample REPORT NO. 25 REG PROJECT NO. 7479 SAMPLE DATE: 04-23-01 TECHNICIAN: B. Steadman Quantity Represented Set Number J Location 1 Piers: A.1-1.1, A. 1-6, A.2-1.2, A.2-5.7 and A.2-6.3 20/20 Design Information I Source of Concrete I Mix Identification I Specified Strength p.s.i. TXI 19 3000 Test Results Set CylinderI I 6413 6413 6413 Age@ Total Load J Compressive J Average Date Tested Test lbs. Strength p.s.i. Strength p.s.i. 04-30-01 7 91570 3240 05-21-01 28 115420 4090 05-21-01 28 122790 4350 4220 Cylinder Data Set ID Slump Sample Air Temp. Temp. Entrainment 6413 5.50 2:45PM 68 74 N/A Ticket Number 2869956 Mail Distribution: (1) Pritchard Associates/ Mr. Roger Dahlin (1) O'Brien & Associates/ Mr. Mick Granlund (1) Technistructures/Mr. Keith Leslie (1) McFadden & Miller, Inc./ Mr. Jon Jacobson (1) Halff Associates/Mr. Dave Littleton (1) City of Coppell/Mr. Larry Davis (1) City of Coppell/Mr. Lee Stone Submitted by: REED ENGINEERING GROUP, INC. Original Signed By Keith E. Atkins KENje 2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019