Park West CC(12)-LR010419 GEOTECHNICAL AND I ~ F=I I""1 U F~
ENVIRONIflENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
Parkwest Commerce Center - Building 5
Enterprise and Wrangler
Coppell, Texas
REPORTED TO:
Pritchard Associates
2501 State Street
Dallas, Texas 75201
ATTN: Mr. Roger Dahlin
REPORT NO. 23
REG PROJECT NO. 7479
SAMPLE DATE: 04-19-01
TECHNICIAN: S. Davis
CONTRACTOR: McFadden & Miller
Location of Sample
Set Number I Location
1
Quantity Represented
Piers: B.5-1, C-1, C.6-1, D-1 and D-1.5
10/10
Design Information
I Source of Concrete I Mix Identification I Specified Strent~[h p.s.i.
TXI 19 3000
Test Results
Set Cylinder I
No. ID Date Tested
1 6286 04-26-01
6286 05-17-01
6286 05-17-01
6286 Hold
Age @
Test
7
28
28
H
Total Load ] Compressive Average
lbs. Strength p.s.i. Strength p.s.i.
78710 2790
Cylinder Data
N;3. I ID Slump Sample Air Temp.
6286 6.00 12:00PM 68
Concrete J Air J Ticket
Temp. Entrainment Number
70 N/A 2867547
Mail
Distribution:
(1) Pritchard Associates/
Mr. Roger Dahlin
(1) O'Brien & Associates/
Mr. Mick Granlund
(1) Technistructures/Mr. Keith Leslie
(1) McFadden & Miller, Inc./
Mr. Jon Jacobson
(1) Halff Associates/Mr. Dave Littleton
(1) City of Coppell/Mr. Larry Davis
(1) City of Coppell/Mr. Lee Stone
Submitted by:
REED ENGINEERING GROUP, INC.
Original Signed By
Keith E. Atkins
KEA/je
2424 STUTZ DR. ,, SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019
GEOTECHNICAL AND
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
Parkwest Commerce Center - Building 5
Enterprise and Wrangler
Coppell, Texas
REPORTED TO:
Pritchard Associates
2501 State Street
Dallas, Texas 75201
ATTN: Mr. Roger Dahlin
McFadden & Miller
REPORT NO. 23
REG PROJECT NO. 7479
SAMPLE DATE: 04-19-01
TECHNICIAN: S. Davis
CONTRACTOR:
Location of Sample
Set Number I Location
1 Piers: B.5-1, C-1, C.6-1, D-1 and D-1.5
J Quantity Represented
10/10
Design Information
Source of Concrete I Mix Identification
TXI 19
Specified Strength p.s.i.
3000
Test Results
Set CylinderI
No. ID Date Tested
1 6286 04-26-01
6286 05-17-01
6286 05-17-01
; 6286 Hold
Age@ TotalLoad J Compressive J Average
Test lbs. Strength p.s.i. Strength p.s.i.
7 78710 2790
28 102810 3640
28 111070 3930 3790
H
Cylinder Data
Set
No.
1
Cylinder I Time of
ID SlumpI Sample
6286 6.00 12:00PM
J J concrete Air Ticket J
Air Temp. Temp. Entrainment Number
68 70 N/A 2867547
Mail
Distribution:
(1) Pritchard Associates/
Mr. Roger Dahlin
(1) O'Brien & Associates/
Mr. Mick Granlund
(1) Technistructures/Mr. Keith Leslie
(1) McFadden & Miller, Inc./
Mr. Jon Jacobson
(1) Halff Associates/Mr. Dave Littleton
(1) City of Coppell/Mr. Larry Davis
(1) City of Coppell/Mr. Lee Stone
Submitted by:
REED ENGINEERING GROUP, INC.
Original Signed By
Keith E. Atkins
KENje
2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 * FAX [214] 350 0019