Park West CC(12)-LR010208GEOTECHNICAL AND ~ J:=J I'""1 I I
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
Parkwest Commerce Center - Building 5
Enterprise and Wrangler
Coppell, Texas
REPORTED TO: Pritchard Associates
2501 State Street
Dallas, Texas 75201
ATTN: Mr. Roger Dahlin
REPORT NO. 12
REG PROJECT NO. 7479
SAMPLE DATE: 02-08-01
TECHNICIAN: F. Gomez
CONTRACTOR: McFadden & Miller
Location of Sample
Set Number J Location
J Quantity Represented
1 Piers: B-8, B-6, B-5 and B-4 10/40
Design Information
I Source of Concrete I Mix Identification I Specified Strength p.s.i.
TXI N/A 3000
Test Results
Set CylinderI
No. ID Date Tested
1 3822 02-15-01
3822 03-08-01
3822 03-08-01
3822 Hold
Age@ Total Load J CompressiveI Average
Test lbs. Strength p.s.i. Strength p.s.i.
7 85630 3030
28 125650 4450
28 134490 4760
H
4610
Cylinder Data
SetI Cylinder J
l NlO. ID Slump
3822 5.50
Time of J ConcreteI Air J Ticket
Sample Air Temp. Temp. Entrainment Number
9:48 AM 70 73 0.2 N/A
Mail
Distribution: (1) Pritchard Associates/
Mr. Roger Dahlin
(1) O'Brien & Associates/
Mr. Mick Granlund
(1) Technistructures/Mr. Keith Leslie
(1) McFadden & Miller, Inc./
Mr. Jon Jacobson
(1) Halff Associates/Mr. Dave Littleton
(1) City of Coppell/Mr. Larry Davis
(1) City of Coppell/Mr. Lee Stone
Submitted by:
REED ENGINEERING GROUP, INC.
Original Signed By
Keith E. Atkins
KEA/mm
2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019
GEOTECHNICALAND I ~ F~ I"-1 I I F~
ENVIRONHENTAL CONSULTANTS
I
CONCRETE CYLINDER TEST REPORT
Parkwest Commerce Center - Building 5
Enterprise and Wrangler
Coppell, Texas
REPORTED TO:
Pritchard Associates
2501 State Street
Dallas, Texas 75201
A'I'TN: Mr. Roger Dahlin
CONTRACTOR: McFadden & Miller
Location of Sample
REPORT NO. 12
REG PROJECT NO. 7479
SAMPLE DATE: 02-08-01
TECHNICIAN: F. Gomez
Set Number I Location I Quantity Represented
1 Piers: B-8, B-6, B-5 and B-4 10/40
Design Information
I Source of Concrete I Mix Identification I Specified Strength p.s.i.
TXI N/A 3000
Test Results
Set Cylinder I
No. ID Date Tested Test
1 3822 02-15-01 7
3822 03-08-01 28
3822 03-08-01 28
3822 Hold H
Age@ TotalLoad J Compressive J Average
lbs. Strength p.s.i. Strength p.s.i.
8563O 3O30
Cylinder Data
Set Cylinder ] I Timeof
No. ID Slump Sample
3822 5.50 9:48 AM
I Concrete I Air I Ticket
Air Temp. Temp. Entrainment Number
70 73 0.2 N/A
Mail
Distribution:
(1) Pritchard Associates/
Mr. Roger Dahlin
(1) O'Brien & Associates/
Mr. Mick Granlund
(1) Technistructures/Mr. Keith Leslie
(1) McFadden & Miller, Inc./
Mr. Jon Jacobson
(1) Halff Associates/Mr. Dave Littleton
(1) City of Coppell/Mr. Larry Davis
(1) City of Coppell/Mr. Lee Stone
Submitted by:
REED ENGINEERING GROUP, INC.
Original Signed By
Keith E. Atkins
KENmm
2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019