Loading...
Park West CC(15)-LR 941130REPORT OF IN-PLACE DENSITY TESTS 4747 I~'YMI Boulevard, Su~ 2M Client: Project: Prentiss Properties Limited, Inc. Wrangler Road Trench Line Coppell, Texas Date: Project No. Report No. Client No. 11/30/94 43-1341-94 941944 Laboratory Test Method: ASTM D-698 optimum M/D No. Material Description % I Dark Brown Clay with Limestone 23.0 Field Test Method: ASTM D-2922 / D-3017 FIELD DENSITY TEST MID Moisture Test No. Test Location No. 64 Street repair, station 7+28 1 21.5 65 Street repair, station 9+75 1 22.4 66 Street repair, station 11+10 1 22.4 67 Street repair, station 12+20 1 22.1 68 Street repair, station 14+00 1 22.0 69 Street repair, station 15+30 1 22.0 Moisture Density (PCF) 97.5 Requirement Moisture Density -2/+4% 95% Dry Density Density (PCF) % 97.7 100.2 96.9 99.4 94.5 96.9 97.6 100.1 97.1 99.5 97.4 99.8 Complies except where noted (*). Technician: J. Landreth Time: 1:00 p.m. - 2:00 p.m. Report Distribution: (1) Prenfiss Properties Limited, Inc. (1) City of Coppell (1) Tri Dal Excavation HBC ENGINEERING, INC. E. Eugene Harbour Vice-President 302AK This report is exclusively for the use of the client indicated above and shall n°t be repr°duced exceflt in ~U ~th°ut the ~ aP~°~l ~ H~ ~' I~