Loading...
Park West CC(15)-LR 941010REPORT OF IN-PLACE DENSITY TESTS 4747 lrvi~ Boule~I:I, Sait~ 206 Dallas, Tes[a~ 7524? Client: Project: Prentiss Properties Limited, Inc. Wrangler Road Trench Line Coppell, Texas Date: Project No. Report No. Client No. 10/10/94 43-1341-94 941506 71765000 Laboratory Test Method: ASTM D-698 MID No. 1 2 3 Material Description Orange and tan shaly clay Dark tan clay with some limestone Dark brown clay with some limestone Optimum Moisture % 22.5 25.0 23.0 Density Requirement (PCF) Moisture Density 98.0 -3/+4 95% 94.5 -3/+4 95% 97.5 -3/+4 95% Field Test Method: ^STM D-2922 / D-3017 Test No. Test Location 30 31 32 33 Sta 10+00, surface test Sta 10+00, 2' below grade Sta 10+00, 4' below grade Sta 10+00, 6' below grade FIELD DENSITY TEST MID Moisture Dry Density Density No. % (PCF) % 2 28.3 91.5 96.8 2 27.6 90.6 95.8 2 28.1 92.3 97.7 2 27.9 92.6 97.9 Complies except where noted (*). Technician: D. Taylor Time: Report Distribution: (1) Prentiss Properties Limited, Inc. (1) Tri Dal Excavation (1) City of Coppell HBC ENGINEERING, INC. E.CJ~ugene Harbour Vice-President 302AK This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc.