Loading...
Park West CC(15)-LR 941005REPORT OF IN-PLACE DENSITY TESTS 4747 L'~ Boulevazl, Suite 206 Dall~, T~ 75247 Client: Project: Premiss Properties Limited, Inc. Wrangler Road Trench Line Coppell, Texas Date: Project No. Report No. Client No. 10/05/94 43-1341-94 941449 Laboratory Test Method: ASTM D-698 M/D No. 1 2 3 Material Description Orange and Tan Shaley Clay Dark Tan Clay with some Limestone Dark Brown Clay with some Limestone Optimum % 22.5 25.0 23.0 Field Test Method: ^STM D-2922/D-3017 Test No. Test Location FIELD DENSITY TEST MID Moisture No. % 12 Station 6+00, surface test Moisture Density Requirement (PCF) Moisture Density 98.0 -3/+4 95% 94.5 -3/+4 95% 97.5 -3/+4 95% 13 Station 6+00, -2 ft. below grade 14 Station 6+00, -4 ft. below grade 15 Station 6+00, -6 ft. below grade 16 Station 6+00, -8 ft. below grade Dry Density Density (PCF) % 1 21.6 97.6 99.6 1 19.3 99.2 101.2 1 21.9 96.6 98.6 1 22.6 97.3 99.3 1 23.3 98.1 100.1 Complies except where noted (*). Technician: D. Taylor Time: Report Distribution: (1) Prentiss Properties Limited, Inc. (1) City of Goppell (1) Tri Dal Excavation 9:30 a.m. to 10:30 a.m. HBC ENGINEERING, INc. E. Eugene Harbour Vice-President 302AK This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc.