Park West CC(17)-LR001019 TSIT
2502 Gravel Drive - Ft. Worth, TX 76118
817-589-9933
Date: October 19, 2000
Report of Built- Up Roof Inspection
PROJECT: Park West 12II Phase lli
Coppell, TX
GENERAL CONTRACTOR: McFadden Miller, Inc.
CONTACT: ~immie Laxen 214-808-4953
ROOFEqG CONTRACTOR: HEC
4815 Gretna - Dallas, Tx 75356
ROOFDqG FOREMAN: Robert Morris 214-638-5970
M/kNLReACTORER: ~'ohns Manville - T,vpe ITI Asphalt - 4 ply with aggregate ballast
Technical Information
WEATHER CONDITIONS: Pt. Cloudy AM. BIEN~F TEMPERATURES: 61 to 84
FORECAST FOR NEXT DAY: Slight chance of rain - rain on weekend
SIZE OF CREW 10 TIME: NA
ROOFING MATERIALS RECEIVED? No LABELS .ATTACHED? Yes
MATERIALS STORED AS REQUIRED? Yes MATERIALS REJECTED? No
SPECII:~D TEMPERATURES: (Asphalt)
Kettle: 500 + 25 degrees F. EVT (Application)' 450 +25 degrees F.
Kettle: 10:30 am- 500 EVT: NA
DECK INSPECTED? Yes
CRICKETS INSTALLED? No Location: NA
AREA OF ROOF APPLICATION: Form expansion joint to north wall
Number of SQ's (SF X 100) placed this date: approximately 100 SQ
Was placement per specifications: Yes
OPEIC&TIONS INSPECTED: Inspection this date at the above referenced project revealed
Insulation application was as required. One layer staggered, mechanically attached fesco ( 8
fasteners per 4' X 8' area) Felt application had begun and was of good quality.
Applied in a lapping fashion, uniform and clean application. No fishmouths, voids or dry
laps noted.
Technician: J. Halverson/Williams Time: 4 hours
Chad McEntee