Loading...
Park West CC(17)-LR000825 1341 West Mockingbird Lane · Dallas, Texas 75247 · 972.647.6700 ° www. txi.com August 25, 2000 Barson Utilities 1802 Spann Dallas, TX 75203 Attn: Mr. John Skinner RE: Wrangler @ Enterprise Coppell 8274 The attached concrete mix design utilizing the appropriate ASTM C-33 or ASTM C-330 aggregate is proposed for use on the above referenced project for ready-mixed concrete to be furnished by TXI. To ensure that the correct mix is delivered to your ~roject, please order by the mix design number which appears in the upper left hand corner of the mix design. Texas Industries certifies that the above mix design, when ordered by specified design identity, and delivered by TXI, will meet or exceed the indicated design strength at the designated age when tested in accordance with the applicable and current ASTM Standards C 31, C 39, C 78, C 172, C 293, applicable provisions of C 94, and evaluated in accordance with applicable provisions of the ACI 318 Building Code. TXI would like to be included on your mailing list to receive all test reports. ASTM C 94 entitles a manufacturer to receive copies of all test reports when strength of concrete is used as a basis for acceptance. Contact us if you have any questions or require any additional information. Please notify TXI of approval of the proposed mix design prior to its use. Failure to notify us prior to first placement shall constitute acceptance. To ensure that the proper mix design is ordered, please send a copy of this letter, after approval, to the above referenced project to be used by the person ordering the concrete for this job. Sincerely, TXI Operations, LP Reedie Stone Customer Service Representative Mix #: 8274 Description: 6.00SK ADMIX/AEA i"CS Strength: 4000 psi @ 28 Days STRUCTURES Maximum Coarse Aggregate: 1" - #4 CRUSHED STONE Maximum Water/Cement Ratio: 5.17 gal/sack or 0.457 lbs/lb Cement/Cementitious Content: 6.00 sacks (per cubic yard) Maximum Placement Slump: 4.00 inches Air Entraining Agent: ASTM C-260 Admixture: ASTM C-494 Type A or D MATERIAL QUANTITIES PER 1.0 CUBIC YARD AT S.S.D 564 lbs. ASTM C 150 TYPE I CEMENT 1840 lbs. 1" - #4 CRUSHED STONE 1273 lbs. CONCRETE SAND 258 lbs. or 31.0 Gallons of Water 2.0 to 4.0 oz/cwt of ASTM C-494 Type D Specified Air Content: 3.0% - 6.0% Placement Slump: 3.00 + or - 1.00 inches PUMPING NOTES / RECOMMENDATIONS 1. 5" minimum diameter lines with no reduction to smaller lines. 2. Keep rubber hose to absolute minimum length and plan pipe with as few 90 degree angles as possible. 3. Samples for slump and strength tests should be taken @ discharge end of hose for strength guarantee to be valid. 4. To prime pump lines, a minimum of 8.0 sack grout should be used for lubrication. In the case of strength concrete, equivalent strength grout should be used if the grout remains in the placement. 5. Pump mixes are based on minimum cement content pumped at ground level. As pump line increases in length or height and/or layout configuration changes, mix design modifications may be required to assure strength and pumpability at additional cost to the contractor. 6. TXI cannot control, and is therefore not responsible for excessive loss of entrained air content when loss occurs as a result of boom configuration or free fall discharge from hose. To ensure minimum air loss when pumping, maintain a continuous flow of concrete through the entire length of pipe and do not subject concrete to free fall. 7. The term "pumpable concrete" refers to concrete which is capable of being transported through an apparatus which forces concrete to the placing position through a pipeline or hose as long as the recommendations indicated above are followed. The term "pumpable concrete" does not relate to concrete proportioned in a particular manner or containing a specific type of product. Unless otherwise indicated, when the concrete temperature at point of placement exceeds 90 degrees Fahrenheit, TXI will guarantee the strength performance of the mix design(s) herein submitted up to a maximum placement temperature of 100 degrees Fahrenheit using an ASTM C 494 Type D retarding water-reducer, as long as the concrete is placed within 75 minutes from batch time. Unless otherwise indicated, strength of plain concrete guaranteed up to a maximum placement temperature of 85 degrees Fahrenheit. We are enclosing all available back up data for the referenced mix design(s). If the strength information is not available, or is insufficient, confirmation tests may have to be conducted by your laboratory. Strength of lightweight mix designs valid provided strength specimens are cured in accordance with ASTM Test Method C 567, as referenced in section 8.1 of ASTM Specification C 330. TF~tS XNDUSTRXF~ COMCR&~E DEBX~I~ EV~UATXCIT Date: 08/25/00 ** Statistics C~iled Fr~ l~p~t L~rato~ Test Spec~ ** M~x ~e~: 8274 Str~: 4000 p~ · 28 Da~ 28 Da~ Tog~ Daka Temperature Test Plant (Fahrenheit) Placement Percent ......... 28 Day ........ Cumulative Moving Number Date Number Ambient Concrete Slump(in) of Air PSI 1 PSI 2 PSI Avg Average Avg of 3 Range 1 12/20/99 45 65 2.50 4.5% 5410 5410 5410 5410 0 2 12/20/99 50 65 2.00 4.5% 5620 5550 5585 5498 70 3 12/21/99 35 2.50 4.1% 4690 5120 4905 5300 5300 430 4 12/21/99 48 56 3.50 4.4% 6050 6010 6030 5483 5507 40 5 12/21/99 42 54 3.00 4.5% 4950 4950 4950 5376 5295 0 6 12/21/99 46 56 3.00 4.0% 5830 5590 5710 5432 5563 240 7 12/27/99 50 61 4.50 4.2% 4680 4510 4595 5312 5085 170 8 12/28/99 42 52 3.50 4.0% 4630 4380 4505 5211 4937 250 9 12/29/99 48 62 2.00 4.0% 6610 6310 6460 5350 5187 300 10 12/29/99 63 64 5.00 4.0% 4460 4350 4405 5256 5123 110 11 12/30/99 66 68 4.25 5.0% 4500 4400 4450 5182 5105 100 12 01/05/00 38 46 5.00 4.5% 4690 4780 4735 5145 4530 90 13 01/06/00 66 66 4.50 3.9% 5230 5280 5255 5153 4813 50 14 01/07/00 47 52 57 5.50 N/A 5080 5110 5095 5149 5028 30 15 01/12/00 31 66 61 5.00 4.9% 4860 4990 4925 5134 5092 130 16 01/14/00 47 52 66 5.00 4.7% 4810 5030 4920 5121 4980 220 17 01/14/00 38 41 68 6.00 N/A 4730 4820 4775 5101 4873 90 18 01/17/00 31 63 5.50 3.9% 4780 4670 4725 5080 4807 110 19 02/09/00 40 70 68 2.50 N/A 5420 5210 5315 5092 4938 210 20 02/10/00 38 71 83 3.75 3.2% 5490 5440 5465 5111 5168 50 21 02/21/00 40 70 76 4.50 N/A 4260 4530 4395 5077 5058 270 22 02/22/00 38 69 79 4.75 3.9% 5330 5620 5475 5095 5112 290 23 04/10/00 31 60 68 5.25 N/A 4770 4750 4760 5080 4877 20 24 06/02/00 25 90 96 4.25 N/A 4410 4540 4475 5055 4903 130 25 06/12/00 87 3.00 3.4% 5280 5370 5325 5066 4853 90 26 06/12/00 50 78 80 4.58 3.5% 4900 5020 4960 5062 4920 120 27 06/12/00 50 77 82 4.00 4.2% 5050 4980 5015 5060 5100 70 28 06/13/00 90 3.50 3.2% 4920 4910 4915 5055 4963 10 29 06/14/00 92 3.50 3.2% 5880 5890 5885 5083 5272 10 30 06/19/00 50 81 84 3.25 N/A 5200 5320 5260 5089 5353 120 ............................... *** Averages *** 58 70 3.97 4.1% COMMENTARY OF STATISTICAL EVALUATION OF CONCRETE DESIGN RESULTS Mix Num: 8274 Strength: 4000 psi ~ 28 Days Paragraph 5.5 of ACI 318-95 provides that as data becomes available during construction, the amount by which (F'cr) must exceed the specified value of (F'c) may be reduced, provided: (a) 30 or more test results are available and average of test results exceeds that required by Section 5.3.2.1, using a standard deviation calculated in accordance with Section 5.3.1.1, or (b) 15 to 29 test results are available and average of test results exceeds that required by Section 5.3.2.1, using a standard deviation calculated in accordance with Section 5.3.1.2. The required average compressive strensth has been calculated using a standard deviation calculated in accordance with ACI 318-89 Section 5.3.1.1 or Section 5.3.1.2 and is the larger value of these calculations: F'cr = F'c + 1.34(SD) = 4000 + 1.34( 509.7) = 4683 F'cr = F'c + 2.33(SD) - 500 = 4000 + 2.33( 509.7) - 500 = 4688 SUMMARY OF STATISTICAL ANALYSIS 28 Day Test Data Number of Tests .......................... 30 Maximum Value ............................ 6460 psi Minimum Value ............................ 4395 psi Range .................................... 2065 psi Average Strength ......................... 5089 psi Standard Deviation ....................... 510 psi Required Average Strength to satisfy minimum probability conditions of ACI 318-89 Section 5.3.2.1 ............... 4688 psi Design excess beyond code requirements... 401 psi ~ MIDLOTHIAN CEMENT PLANT * 245 Ward Road * Midlothian, Texas 76065 · www.txi.com SPECIFICATIONS Portland Cement Type 1/11 (Low Alkali) A.S.T.M. C150-98 Bin Number Car Number Tons Date of Sampling July-2000 Monthly Average I ASTM TEST SPECIFICATION RESULTS CHEMICAL REQUIREMENTS ~ ' · · .- Silica Oxide, Minimum Percent 20.0 20.6 Alumina Oxide, Maximum Percent 6.0 4.3 Iron Oxide, Maximum Percent 6.0 3.7 Magnesia Oxide, Maximum Percent 6.0 1.2 SO3 (C3A less than 8%), Maximum Percent * 3.2 Loss on Ignition, Maximum Percent 3.0 1.0 Insoluble Residue, Maximum Percent 0.75 0.16 Tricalcium Aluminate, Maximum Percent 8.0 5 . OPTIONAL CHEMICAL REQUIREMENTS Total Alkalies, Max. % (Na20 equiv.) I 0.60 I 0.46 "-. ..... . PHYSICAL'REQUIREMENTS ,.- ':- ";." ...-.-' - .;~ '" .... Specific surface, Blaine Minimum (m2/kg) 280 350 Gillmore, Initial Set, Minimum (Minutes) 60 161 Gillmore, Final Set, Maximum (Minutes) 600 276 Vicar, IMinimum (Minutes) 45 Initial Set I Maximum (Minutes) 375 98 Air Content, Volume, Maximum Percent 12 6 Autoclave Expansion, Maximum Percent 0.80 0.00 Minimum Compressive Strengths MPa psi MPa psi 3 Day 12.0 1740 24.8 3597 7 Day 19.0 2760 31.0 4491 STATE OF TEXAS Jeff Wendel , being duly sworn deposes and says; that he is Quality Services Manager of TXI Midlothian Cement Plant, who prepared the above report of tests Subscribedj~nd sworn to before me on this date: August 11, 2000 / ~N ~~P~ub~ic~~'~ Q~[~S 9~¢'~'es M an age r · See ASTM C150 Table I Footnote D. Grac~ Construction Prc~uc~ ~~It~GE W.R. Grace & Co. -Conn. 4323 Crites Street P.O. Box 2585-77252 Houston, TX 77003 May 30,2000 TXI 1341 West Mockingbird Lane Dallas, TX 75247 Gentlemen: This is to certify that DARATARD® 17, a water-reducing & retarding admixture, as manufactured and supplied by Grace Construction Products, W. R. Grace & Co.-Conn., is formulated to comply with Specification for Chemical Admixtures for Concrete, ASTM Designation: C 494, Type D (AASHTO M 194, Type D). DARATARD® 17 does not contain calcium chloride or chloride containing compounds as a functional ingredient. Chloride ions may be present in trace amounts contributed from the domestic water supply used during the manufacturing process. The above is in addition to and not in substitution for our standard Conditions of Sale,printed on the reverse side hereof. Fred Hightower Technical Services Subscribed and sworn to, before me, this ~7 / day of /')1 ~ '~._ , ,2000... Notary Public My commission expires: We hope the information given here will be helpful. II is based on our best knowledge, and we believe it ro be true and occuram. Please read all stafements, recommen~fions or suggestions herein in conjunction with our conditions o~ ~le which apply to all go~s suppl;~ by us. We o~ume no res~nsibili~ for Ihe u~ of these statements, recommendo ions, or suggestions, nor do we inlend Ihem as o recommendation for any use which would infringe any ~tenl o~ ¢opyrighl. ,4323 ~ ~ ' · 30,2000 P.O. BaK 2585-77252 7.5'247 . ... This is to certify that DARAVAIR° 1000, an air-~ntraining.admixtur~, .as man~ and supplied by. Oraca ~ P~oducts, w. ~ Grac~ tt Co.;Conn., is formulated to .c~. 'ply wi~ Specifi¢-~On' for. Air.~ Admbtmres for Coherete, AsTM Design~on: c 260 (XASHTO DARAV~~ 1000 does not contain calcium chloride or chloride containing compounds as a .funclional ingredient..Chlorid~ ions may bi! present in trace amounts co~ltributed from the domestic wa~r supply used during the manufacturing process.- The forgoing is in addition to and not in substitution for our standard Conditions of Sale pr/nted on the.r~vers~ side hereof. F~I ltightoWer. T~i~I Services WeholN,~einf&-,~llu~,i/v~ilvwewlHbehell~ul. Itk, badedeneurlNsllmewlm:~.lndwebe#eq,~lllolNIrveondaccumle, hr, e41dalllr~ls~.,.fl'l~. TEXAS INDUSTRIES QUALITY CONTROL DEPT. AGGREGATE SIEVE ANALYSIS Date: 10/12/99 Production Facility: MERIDIAN Size: 5__7 Grading Designation: ASTM C-33 1" - #4 Project: *****ALL TESTS* .... Sample Location: SIEVE CUMULATIVE CUMULATIVE CUMULATIVE REQUIRED SPECIFICATION SIZE WT. RETAINED % RETAINED % PASSING % RETAINED % PASSING 1.5" 1.0" .36 99.64 0 - 5 95 - 100 %" 20.28 79.72 %" 56.73 43.27 40 - 75 25 - 60 3~8" 77.76 22.24 - ~ 97.44 2.56 95 - 100 0 - 10 #8 99.87 .13 95 - 100 0 - 5 #10 #16 #30 #40 #50 #100 #200 PAN WT. 100% of tests: 9 Size: 57 PLANT: MERIDIAN Job: ....... ALL JOBS ....... TEXAS INDUSTRIES QUALITY CONTROL DEPT. AGGREGATE SIEVE ANALYSIS Date: 01/27/00 Production Facility: TXI WADE SAND Designation: C 33 Grading Designation: ASTM C-33 FINE AGG. Project: *****ALL TESTS ..... Sample Location: SIEVE CUMULATIVE CUMULATIVE CUMULATIVE REQUIRED SPECIFICATION SIZE WT. RETAINED % RETAINED % PASSING % RETAINED % PASSING 2.0~ 3/8" 0.00 100 0 100 #4 4.13 95.87 0 - 5 95 - 100 #8 13.60 86.40 0 - 20 80 - 100 #10 #46 24.11 75.89 15 - 50 50 - 85 #30 50.30 49.70 40 - 75 25 - 60 #-40 #50 86.43 13.57 70 - 90 10 - 30 #100 95.43 4.47 90 o 98 2 o 10 ~200 98.33 1.67 PAN WT. Fineness Modulus: 2.74 M.C. Decant S.E. ~00% of tests: 7 Size: 33 P~NT: TXI WADE SAND Job: * ..... *ALL JOBS .......