Peninsulas-LR 950607 ALPHA TESTING, ~..~.
2209 Wisconsin St., Suite 100 REPORT OF FIELD
Dallas, Texas 75229 COMPACTION TESTS
(214) 620-8911
TESTED FOR: PERRY HONES DATE: 06/07/95
HOUSTON, TEXAS
PROJECT: McARTHUR PARK OUR REPORT NO. 94526-17
COPPELL, TEXAS
TEST DATA:
TEST ~ELEV. SOILID OPTIMUM M~IMUMLAB INPLACE INPLACE PERCENT
NO. DATEDEPTH"~ MOISTURE DRYDENSITY MOISTURE DRYDENSI~ COMPACTION COMMENT*
NUMBER % PCF % PCF
46 06/07 FG 2L 20.0 104.0 22.3 102 98 1-A
47 06/07 FG 2L 20.0 104.0 23.1 102 98 1-A
48 06/07 FG 2L 20.0 104.0 24.0 100 97 1-A
49 06/07 FG 2L 20.0 104.0 22.0 101 97 I-A
50 06/07 FG 2L 20.0 104.0 21.0 103 99 1-A
51 06/07 FG 2L 20.0 104.0 20.0 104 100 1-A
52 06/07 FG 2L 20.0 104.0 21.4 102 98 1-A
TESTLOCATION:
46 EAST PENINSULA STA. 1+50; CENTER LINE
47 EAST PENINSULA STA. 4+00; CENTER LINE
48 EAST PENINSULA STA. 6+50; CENTER LINE
49 EAST PENINSULA STA. 9+10; CENTER LINE
50 SENT TREE COURT STA. 2+20; CENTER LINE
51 BENT TREE COURT STA. 4+50; CENTER LINE
52 SENT TREE COURT STA. 8+00; CENTER LINE
1. FILL * A. TEST RESULTS COMPLY WITH SPECIFICATIONS Re~miffed,~_~~ ~
2. NATURAL SUBGRADE B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
ALPHA TESTING, ~,,C.
2209 Wisconsin St., Suite 100 REPORT OF FIELD
Dallas, Texas 75229 COMPACTION TESTS
(214) 620-8911
TESTED FOR: PERRY HOMES DATE: 06/07/95
HOUSTON, TEXAS
PROJECT: HcARTHUR PARK OUR REPORT NO. 94526--17A
COPPELL, TEXAS
TEST DATA:
TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT
NO. DATEDEPTH-"~,,.~ MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT*
NUMBER % PCF % PCF
53 06/07 FG 2L 20.0 104.0 22.0 103 99 1-A
54 06/07 FG 2L 20.0 104.0 23.1 102 98 i-A
TEST LOCATION:
S3 NORTH SHORE COURT STA. l+SO; CENTER LINE
54 NORTH SHORE COURT STA. 4+10; CENTER LINE
1. FILL * A. TEST RESULTS COMPLY WITH SPECIFICATIONS
2. NATURAL SUBGRADE B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
3. LIME STABILIZED C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS