Peninsulas-LR 950524 ALPHA TESTING, Ir~C.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229 DALLY FIELD REPORT
(214) 620-8911
TESTED FOR PERRY HONES INC. ;)ATE 05/24/95
HOUSTON, TEXAS
PROJECT McARTHUR PARK OUR REPORT NO. 94526--11
COPPELL, TEXAS
CLOUDY
WEATHER:
70 90
TEMPERATURE RANGE: TO:
J.B.
ALPHA Re~'eaentalive:
THE ALPHA TECHNICIAN TRAVELED TO THE PROJECT SITE AS REQUESTED BY THE
CLIENT'S REPRESENTATIVE, TO PERFORM FIELD DENSITY TESTING AND VERIFY
SUBGRADE PREPARATION.
SUBGRADE FOR BUILDING PAD AREAS WAS VISUALLY INSPECTED TO ASSURE THAT ALL
VEGETATION HAD BEEN PROPERLY REMOVED AND THAT PAD AREAS HAD BEEN PREPARED
IN ACCORDANCE WITH GEOTECHNICAL RECOMMENDATIONS. LOTS ONE, AND THIRTEEN
THROUGH FIFTEEN ON BLOCK "A" WERE INSPECTED AND APPEARED TO COMPLY WITH
GEOTECHNICAL RECOMMENDATIONS.
A TOTAL OF ELEVEN FIELD DENSITY TESTS WERE PERFORMED ON FILL AND NATURAL
SUBGRADE SOILS FOR THE LOT AND STREET FILL AREAS. SEE ATTACHED REPORT OF
FIELD COMPACTION TESTS.
JOHN WAS INFORMED OF TEST RESULTS WHICH APPEARED TO COMPLY WITH PROJECT
SPECIFICATIONS.
TECHNICIAN RETURNED TO THE LABORATORY UPON COMPLETION OF SCHEDULED TESTING
AND INSPECTIONS.
ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100 REPORT OF FIELD
Dallas, Texas 75229 COMPACTION TESTS
(214) 620-8911
TESTED FOR: PERRY HOMES DATE: 05/24/95
HOUSTON, TEXAS
McARTHUR PARK 94526-1 iA
PROJECT: OUR REPORT NO.
COPPELL , TEXAS
TEST DATA:
TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT
NO. DATEDi=PTH~,,,~ MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT*
NUMBER % PCF % ' PCF
25 05/24 SG I 20.0 102.0 21.6 99 97 2-A
26 05/24 FG I 20.0 102.0 22.4 97 95 i-A
27 05/24 SG i 20.0 102.0 23.0 97 95 2-A
28 05/24 SG I 20.0 102.0 21.6 97 96 2-A
29 05/24 FG I 20.0 i02.0 21.0 99 97 1-A
30 05/24 FG-1.8 I 20.0 102.0 20.9 100 180 1-A
31 05/24 FG-O .2 1 20.0 102.0 21.7 97 95 1-A
TEST LOCATION:
25 WEST PENINSULA DR. STATION 6+00
26 WEST PENINSULA DR. STATION 6+00
27 LOT FILL AREA 8LOCK A LOT
28 LOT FILL AREA 8LOCK A LOT
29 LOT FILL AREA 8LOCK A LOT 13
30 LOT FILL AREA BLOCK A LOT 14
31 LOT FILL AREA BLOCK A LOT 14
1. FILL * A. TEST RESULTS COMPLY WITH SPECIFICATIONS
2. NATURAL SUBGRADE B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
4. CEMENT TREATED D. RETEST
ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100 REPORT OF FIELD
Dallas, Texas 75229 COMPACTION TESTS
(214) 62o-8911
TESTED FOR: PERRY HOHE5 DATE: 05/24/<)5
HOUSTON, TEXAS
PROJECT: McARTHUR PARK OUR REPORT NO. <)452(>-- 11B
COPPELL, TEXAS
TEST DATA:
TEST ~ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT
NO. DATEDEPTH-..,~a MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT*
NUMBER % PCF % ' PCF
32 05/24 SG I 20.0 102.0 21.7 <)8 <)6 2-A
33 05/24 FG-1.3 I 20.0 102.0 20.6 9<) <)7 1-A
34 05/24 FG-O .4 1 20.0 102.0 22.5 <:)7 <::)5 1-A
35 05/24 FG 1 20.0 102.0 21 . 1 98 96 1-A
TEST LOCATION:
32 LOT FILL AREA BLOCK A LOT 15
33 LOT FILL AREA 8LOCK A LOT 1
34 LOT FILL AREA BLOCK A LOT 1
35 LOT FILL AREA BLOCK A LOT 1
2. NATURAL SUBGRADE S. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
3. LIME STABILIZED C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS -~AL-laN~T~ST/.JNG, INC.
4. CEMENT TREATED D. RETEST ~p. Stj~ctne
ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229 DALLY FIELD REPORT
(214) 620-8911
TESTED FOR PERRY HOMES INC. DATE 05/24/95
HOUSTON , TEXAS
PROJECT McARTHUR PARK OUR REPORT NO. 94526--9
COPPELL, TEXAS
WEATHER: CLOUDY
TEMPERATURE RANGE: 73 TO: 84
B.C.
ALPHA Representative:
THE ALPHA TECHNICIAN TRAVELLED TO THE PROJECT SITE AS REQUESTED 8Y THE
CLIENT'S REPRESENTATIVE, TO OBTAIN A SOIL SAMPLE FOR LABORATORY LIME SERIES
ANALYSIS.
ONE SAMPLE WAS OBTAINED FROM THE FOLLOWING LOCATION:
SAMPLE A- WEST PENINSULA DRIVE, STATION 3+50.
THE SAMPLE WAS RETURNED TO THE LABORATORY FOR ANALYSIS.
TEST RESULTS WILL FOLLOW ON A SEPARATE REPORT.