Park West CC(17)-LR 981124 CONTRA CT INSPECTION SER VICE, Inc. 4305 Glenwood Ct. Granbury, TX 76049 (817) 246-8096 FAX (817) 246-5889 REPORT OF STRUCTURAL ERECTION INSPECTION Project: Park West Commerce Center Report No: 11368-8 Coppell, TX Attention: Keith Atkins Client: Reed Engineering Group Date of Service: 11-24-98 2424 Stutz, Suite 400 Dallas, TX 75235 Page 1 of 1 I REPORT OF INSPECTION Drawings utilized: Contract Documents/AWS D1.1-96/AJI/AISC Locations/item inspected: Column line 1 to 6, grid line A to F Discrepancies/comments: A visual inspection was conducted on the above referenced project with results as follows. 1 .) Joist to joist girder welds and bearing found to comply. 2.) Joist girder to column connections, welds and bearing found to comply. 3.) Joist girder to tilt panel connections, welds and bearing found to comply. 4.) Joist to tilt panel connections, welds and bearing found to comply. 5.) Bridging installed and found to comply. 6.) Anchor bolts were found to comply for: a.) Nut engagement b.) Snug tight tensioning. Technician ~tract Inspection Se~ice This report is for the exclusive use of our client and shall not be modified or reproduced without written approval from said client