Loading...
Peninsulas-LR 950518 ALPHA TESTING, INC. REPOR'I OF CONCRETE 22o9 W,scons,n St COMPRESSION TEST "' Suite 100 Dailas. Texas 75229 (214~ 620-8911 PERRY HOMES MAY 18, 1995 HOUSTON, TEXAS OUR REPORT NO MACARTHUR PARK 94526-12 IRVING, TEXAS FIELD DATA LOCATION OF CONCRETE PLACEMENT INLET AT LATERA OFF STORM SEWER SD-A - STA 2+89 DATE PLACED PLANT 05/18/95 1 T~ME DELIVER TICKET NO 15:55 SLUMP MIX PROPORTIONS ~SSD) 12835 5 N/A AIR CONTENT CEMENT N/A N/A AIR TEMPERATURE WATER 73 N/A CONCRETE TEMPERATURE FINE AGGREGATE DATE RECEIVED 78 COARSE AGGREGATE N/A FIELD DATA SUBMITTED 8Y 05/ i 9/95 ADMIXTURE N/A D.M. N/A MIX DATA SUSMI]'-TED BY REDI MI X REMARKS COMPRESSION TEST RESULTS (NOMINAL CYLINDER SIZE 6" X 12"1 ~Cy__ hnders made by ALPHA represenlatlve. La'a Customer Type Date _~e Coml~'e~,eva ._.._ CyhndeFs made Dy Architect's No No. Curm~ T~ted Days Stren~h. P,, or Con~ractor's representafwe ~_~_'~Cyhnders picked up by ALPHA 1 94526 LAB 05/25/95 7 3320 lal~ratory ~. Cylinders delivered to ALPHA 2 94526 LAB 06/15/95 28 (aboratory. ~_J Compression test results comply w~th 3 94526 LAB ', 06/ 15/95 28 applicable spec~flcahons. 4 94526 LAB HOLD [..~ Compression test results do no* comp!y : w~h applicable spec~t~cal~ons is~.~ .... ~ ..... ~ 28 3000 TYPE OF FRACTURE. IF OTHER _~;N CONICAL ~ctlully Submitted DAVID P. STETTNER ALPHA TESTING. INC ALPHA TESTING, INC. REPORT OF CONCRETE 2209 W,scons,n St COMPRESSION TEST Suite 100 Dallas. Texas 75229 :'?'"" (2141620-8911 T[STED FOR DATE PERRY HOMES MAY 18, i995 HOUSTON, TEXAS PHOJECT OUR REPORT NO. MACARTHUR PARK 94526-12 IRVING, TEXAS FIELD DATA LOCATION OFCONCRETEPLACEMENT INLET AT LATERA OFF STORM SEWER SD-A - STA 2+89 PLANT DATE PLACED 05/ 18/95 DELIVER TICKET NO. 1 TIME i 5 -' 55 MIX PROPORTIONS (SSD) 12835 SLUMP 5 CEMENT N/A A~R CONTENT N/A WATER N/A AIR TEMPERATURE 73 FINE AGGREGATE N/A CONCRETE TEMPERATURE 78 COARSE AGGREGATE N/A DATE RECEIVED FIELD DATA SUBMITTED ev 05/ 19/95 ADMIXTURE N/A D.M. N/A MIX DATA SUBMI]-rED BY REDI MI X REMARKS COMPRESSION TEST RESULTS INOMINAL CYLINDER SIZE S" X 12"1 ..~ Cy~ hnders made by ALPHA ~epresentat~ve. Lab Cultomet Ty~ Dill D~A~y. Com~emwe ~_ Cyhnders made by Architect's No. No. Curtl~ Tempi Sirrah. Psi or Contractor's representahve ~'"'~'Cylinders p,cked up by ALPHA 1 94526 LAB 05/25/95 7 3320 laborato~. L_'--: Cylinders dehvered to ALPHA 2 94526 LAB 06/15/95 28 4150 ~aboratory .': .-~'"'~compression test results comply w~th 3 94526 LAB 06/15/95 28 4110 applicable specifications. ~ Compression test results do no~ comp!y 4 94526 LAB HOLD with applicable speoflcat,ons !spec,,.ca~.o~s 2~ 3000 TYP~r.~ PRAGTU~. IF OTHER L