Peninsulas-LR 950502 ALPHA TESTING, h,C.
2209 Wisconsin St.. Suite 100 REPORT OF FIELD
Dallas, Texas 75229 COMPACTION TESTS
(214) 620-8911
TESTED FOR: PERRY HO~S DATE: 05/02/95
HOUSTON, TEXAS
NcARTHUR PARK 94526-6
PROJECT: COPPELL, TEXAS OUR REPORT NO.
TEST DATA:
MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT*
NO. DATE DEPTH NUMBER % PCF % PCF
9 05/02 FG-5 i 20.0 102.0 21.1 98 96 1-A
10 05/02 F6-4 I 20.0 102.0 22.7 98 96 1-A
11 05/02 FG-3 I 20.0 102.0 23.7 9"9 97 1-A
12 05/02 FG-2 I 20.0 102.0 23.3 97 95 1-A
13 05/02 FG-4 I 20.0 102.0 21.5 101 99 1-A
14 05/02 FG-2 1 20.0 102.0 21.1 100 98 1-A
TEST LOCATION:
9 8" SANITARY SEWER LINE "A" STA. 8+50
10 8" SANITARY SEWER LINE "8" 5TA. 2+00
11 8" SANITARY SEWER LINE "8" STA. 3+00
12 8" SANITARY SEWER LINE "8" STA. 4+00
13 8" SANITARY SEWER LINE "C" 5TA. 3+00
14 8' SANITARY SEWER LINE 'C' STA. 4+00
1. FILL A. TEST RESULTS COMPLY WITH SPECIFICATIONS
2. NATURAL SUBGRADE B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
3. LIME STABILIZED C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
4. CEMENT TREATED D. RETEST