Loading...
Petterson Addn-CS 981119 CITY OF COPPELL PLANNING DEPARTMENT STAFF REPORT CASE: PETTERSON ADDITION, MINOR PI,AT P & Z HEARING DATE: November 19, 1998 C.C. HEARING DATE: December 8, 1998 LOCATION: 326 W. Sandy Lake Road. SIZE OF AREA: 2.4 ac. being platted into two lots for duplex development CURRENT ZONING: 2F-9 (Duplex) REQUEST: Minor Plat approval of two lots. Lot #1 is shown as being !.59 acres in size, Lot #2 as being .68 acres in size APPLICANT: Owner: Engineer: Nancy J. Petterson Walter Nelson and Assoc, 326 Sandy Lake Road 1002 W. Wall Street Coppell, Tx. 75019 Grapevine, Tx. 76051 (214) 924-8484 (817) 329-1576 Fax: (972)401-2685 Fax: (817)3294723 HISTORY: There has been no recent development history on the subject tract. TRANSPORTATION: Sandy Lake Road is projected to be a C4D/6 contained within a 100 foot r.o.w. Today it is a two lane asphalt paved road in a 60 foot r.o.w. SURROUNDING LAND USE & ZONING: North - single family residential; Planned Development #148 South - developing single-family; SF-7 East - single family residential; Planned Development #148 West - large lot single family; SF-12 COMPREHENSIVE PLAN: The Comprehensive Plan shows the property as suitable for low density residential development. Item # 14 DISCUSSION: The applicant proposes to plat this property into two lots that will accommodate two residences each on this duplex zoned parcel. As explained to staff, Lot//1 will accommodate the applicant's home on the rear portion of the lot, a relatives residence on the portion immediately adjacent to lot //2. He has provided the attached sketch plan to delineate one way Lot //1 might be developed. He was cautioned that access to the northern alley would not be allowed from Sandy Lake Road and that his sketch plan would have to be altered. Please note that change has been reflected in the submitted Conceptual Site Plan. At staff suggestion, the applicant has provided a note on the plat that indicates all houses on the property will contain a fully automatic fire sprinkler system. In addition, the applicant is aware that access to garage structures for all residences build on either lot will be from the alley only, and a note so indicating is shown on the conceptual site plan. A tree survey has been included with this request. RECOMMENDATION TO THE PLANNING AND ZONING COMMISSION: The planning staff recommends approval of this minor plat subject to the Departmental comments included from Building Inspection and Fire. The applicant has complied with these comments. ALTERNATIVES: 1) Recommend approval of the request 2) Recommend disapproval of the request ATTACHMENTS: 1) Departmental Comments 2) Sketch of Possible Site Plan 3) Minor Plat Document 4) Conceptual Site Plan 5) Tree Survey Item//14 DEVELOPMENT REVIEW COMMl l TEE BUILDING INSPECTION COMMENTS OCT 2 DRC DATE: October 29, 199S J., CONTACT: Greg Jones, Chief Building Off~__'_o! (304-3500) COMMENT NTA TUS: ~' ~ P~ELIMINARY FINAL 1. No floor plandinited site plan information included- hnpossible to detern~e what conamnts will be appropriate. drc12345 DEVELOPMENT REVIEW COMMITTEE FIRE PREVENTION COMMENTS ITEM: PETTERSON ADDI110N DRC DATE: OCTOBER 29, 1998 CONTACT: TRAVIS CRUMP, FIRE MARSHAL. (214) 304-3503 COMMENT STATUS: INITIAL PRELIMINARY FINAL 1. Fire lane to be platted as a 24 feet wide easement. However, actual width of fire lane can be 16 feet if the notation "All residential structures to be equipped with a functioning fully automatic fire sprinkler system. If the fire sprinkler systems are removed or cease to function, a full twenty-four feet (24') wide fire lane shall be installed." is placed on the face of the plat.