Loading...
Park West CC(18)-CS 890811 (2),~~ MASON JOHNSTON & ASSOCIATES, lac. · · geotechnica/consultants Raymond C. Mason. P.£. Choirman of the Board 11 August, 1~89 AubreyD. Henley, R.G.,C.E.G. Pres/dent T. Daniel Bos! Vice-President Richard C. Mason Prentiss Properties Limited, Inc. 1'~17 Main Street Suite 5000 Dallas, texas 75201 Attention: Mr. John S. Lehigh, V.?. Re: Park West Commerce Center '£raet 1 Coppell, Texas MJ 5566 Gentlemen: Further pavement ~nickness analyses at the referenced site indicate that the concrete thickness for fire lanes, service drives, etc. should be 6 inches of reinforced concrete paving with No. 3 re-steel at 18 inches on centers each way. In parking and o~her areas, the 5 inches of reinforced concrete paving recommended in our Report MJ 5566 should be used. All concrete pavement should De on 6 inches of lime stabiiized, compacted subgrade. We trust tnis clarifies our pavement recommendations. Please call me if you have any questions. Very truly yours, ~.-~ ~ ..~-,~ Mason-Johnston b Assoc.--Inc. cc: Don P. GerRen, PPL Donald E. Davis Paul Maute, NHBH 235 Morgan Ave., Dallas, Texas 75203-1088 (214) 941-3808