Park West CC(18)-CS 890811 (2),~~ MASON
JOHNSTON
& ASSOCIATES, lac.
· · geotechnica/consultants
Raymond C. Mason. P.£.
Choirman of the Board
11 August, 1~89 AubreyD. Henley, R.G.,C.E.G.
Pres/dent
T. Daniel Bos!
Vice-President
Richard C. Mason
Prentiss Properties Limited, Inc.
1'~17 Main Street
Suite 5000
Dallas, texas 75201
Attention: Mr. John S. Lehigh, V.?.
Re: Park West Commerce Center
'£raet 1
Coppell, Texas
MJ 5566
Gentlemen:
Further pavement ~nickness analyses at the referenced site
indicate that the concrete thickness for fire lanes, service
drives, etc. should be 6 inches of reinforced concrete paving
with No. 3 re-steel at 18 inches on centers each way. In
parking and o~her areas, the 5 inches of reinforced concrete
paving recommended in our Report MJ 5566 should be used. All
concrete pavement should De on 6 inches of lime stabiiized,
compacted subgrade.
We trust tnis clarifies our pavement recommendations. Please
call me if you have any questions.
Very truly yours, ~.-~ ~ ..~-,~
Mason-Johnston b Assoc.--Inc.
cc: Don P. GerRen, PPL
Donald E. Davis
Paul Maute, NHBH
235 Morgan Ave., Dallas, Texas 75203-1088 (214) 941-3808