Reserve-LR 990916 1341 West Mockingbird Lane · Dallas, Texas 75247 · 972.647.6700~w~fw.txi.com Austin Bridge & Road 11143 Goodnight Lane Dallas, TX 75229 RE: The Reserve - Coppell - ' 8272 8274 The attached concrete mix designs utilizing the appropriate ASTM C-33 or ASTM C-330 aggregate are proposed for use on the above referenced project for ready-mixed concrete to be furnished by TXI. To ensure that the correct mix is delivered to your project, please order by the mix design number which appears in the upper left hand corner of the mix design. Texas Industries certifies that the above mix designs, when ordered by specified design identity, and delivered by TXI, will meet or exceed the indicated design strength at the designated age when tested in accordance with the applicable and current ASTM Standards C 31, C 39, C 78, C 172, C 293, applicable provisions of C 94, and evaluated in accordance with applicable provisions of ACI Building Code. TXI would like to be included on your mailing list to receive all test reports. ASTM C 94 entitles a manufacturer to receive copies of all test reports when strength of concrete is used as a basis for acceptance. Please contact us if you have any questions or require any additional information. Please notify TXI of approval of the proposed mix designs prior to their use. Failure to notify us prior to first placement shall constitute acceptance. To ensure that the proper mix designs are ordered, please send a copy of this letter, after approval, to the above referenced project to be used by the person ordering the concrete for this job. Sincerely, TXI Operations, LP Reedie Stone Customer Service Representative Mix #: 8272 Description: 5.00SK ADMIX/AEA i"CS Strength: 3000 Dm~ @ 28 Days SLIP FORMED PAVING Maximum Coarse Aggregate: 1" - #4 CRUSHED STONE ~ Maximum Water/Cement Ratio: 6.20 gal/sack or 0.549 lbs/lb Cement/Cementitious Content: 5.00 sacks (per cubic yard) Maximum Placement Slump: 4.00 inches ~ Air Entraining Agent: ASTM C-260 Admixture: ASTM C-494 Type A or D MATERIAL QUANTITIES PER 1.0 CUBIC YARD AT S.S.D 470 lbs. ASTM C 150 TYPE I CEMENT 1840 lbs. 1" - #4 CRUSHED STONE 1352 lbs. CONCRETE SAND 258 lbs. or 31.0 Gallons of Water ~/ 2.0 to 4.0 oz/cwt of ASTM C-494 Type D Specified Air Content: 3.0% - 6.0% Placement Slump: 3.00 + or - 1.00 inches Mix #: 8274 Description: 6.00SK ADMIX/AEA I"CS Strength: 4000 psi @ 28 Days HAND PLACED PAVING Maximum Coarse Aggregate: 1" - #4 CRUSHED STONE Maximum Water/Cement Ratio: 5.17 gal/sack or 0.457 lbs/lb Cement/Cementitious Content: 6.00 sacks (per cubic yard) Maximum Placement Slump: 5.00 inches Air Entraining Agent: ASTM C-260 Admixture: ASTM C-494 Type A or D MATERIAL QUANTITIES PER 1.0 CUBIC YARD AT S.S.D 564 lbs. ASTM C 150 TYPE I CEMENT 1840 lbs. 1" - #4 CRUSHED STONE 1273 lbs. CONCRETE SAND 258 lbs. or 31.0 Gallons of Water 2.0 to 4.0 oz/cwt of ASTM C-494 Type D Specified Air Content: 3.0% - 6.0% ~ Placement Slump: 4.00 + or - 1.00 inches PUMPING NOTES / RECOMMENDATIONS 1. 5" minimum diameter lines with no reduction to smaller lines. 2. Keep rubber hose to absolute minimum length and plan pipe with as few 90 degree angles as possible. 3. Samples for slump and strength tests should be taken @ discharge end of hose for strength guarantee to be valid. 4. To prime pump lines, a minimum of 8.0 sack grout should be used for lubrication. In the case of strength concrete, equivalent strength grout should be used if the grout remains in the placement. 5. Pump mixes are based on minimum cement content pumped at ground level. As pump line increases in length or height and/or layout configuration changes, additional cement may be required to assure strength and pumpability at additional cost to the contractor. 6. TXI cannot control, and is therefore not responsible for excessive loss of entrained air content when loss occurs as a result of boom configuration or free fall discharge from hose. To ensure minimum air loss when pumping, maintain a continuous flow of concrete through the entire length of pipe and do not subject concrete to free fall. 7. The term "pumpable concrete" refers to concrete which is capable of being transported through an apparatus which forces concrete to the placing position through a pipeline or hose as long as the recommendations indicated above are followed. The term "pumpable concrete" does not relate to concrete proportioned in a particular manner or containing a specific type of product. Unless otherwise indicated, when the concrete temperature at point of placement exceeds 90 degrees Fahrenheit, TXI will guarantee the strength performance of the mix design(s) herein submitted up to a maximum placement temperature of 100 degrees Fahrenheit using an ASTM C 494 Type D retarding water-reducer, as long as the concrete is placed within 75 minutes from batch time. Unless otherwise indicated, strength of plain concrete guaranteed up to a maximum placement temperature of 85 degrees Fahrenheit. We are enclosing all available back up data for the referenced mix design(s). If the strength information is not available, or is insufficient, confirmation tests may have to be conducted by your laboratory. Strength of lightweight mix designs valid provided strength specimens are cured in accordance with ASTM Test Method C 567, as referenced in section 8.1 of ASTM Specification C 330. TEllS IIfI~S~IES CONCRETE DESIGN EVALUATION Date: 09/16/99 ** Statistics Compiled ~oa Independent Laboratory Test Specimens Nix l~mber: 8272 Strength: 3000 psi @ 28 Days 28 Day Test Data Temperature Test Plant (Fahrenheit) Placement Percent ......... 28 Day ........ Cumulative Moving Number Date Number Ambient Concrete Slump(in) of Air PSI 1 PSI 2 PSI Avg Average Avg of 3 Range 1 04/20/99 72 5.00 4.4% 3880 3950 3915 3915 70 2 04/20/99 73 5.50 4.1% 3840 3870 3855 3885 30 3 04/20/99 70 5.00 4.5% 3580 3860 3720 3830 3830 280 4 04/20/99 70 5.25 4.3% 3310 3500 3405 3724 3660 190 5 04/21/99 46 68 72 4.75 N/A 4180 4260 4220 3823 3782 80 6 04/22/99 43 67 73 5.75 N/A 3930 4000 3965 3847 3863 70 7 04/28/99 77 5.00 1.6% 3960 3820 3890 3853 4025 140 8 04/28/99 74 6.50 4.5% 4030 3880 3955 3866 3937 150 9 04/28/99 75 7.25 4.3% 3650 3560 3605 3837 3817 90 10 04/29/99 12 79 60 6.00 N/A 3960 3700 3830 3836 3797 260 11 05/05/99 88 5.25 3.8% 3690 3780 3735 3827 3723 90 12 05/05/99 82 5.00 3.5% 3420 3570 3495 3799 3687 150 13 05/05/99 85 5.25 3.6% 3450 3560 3505 3777 3578 110 14 05/05/99 86 5.50 3.6% 3470 3840 3655 3768 3552 370 15 05/05/99 84 5.00 3.4% 3790 3830 3810 3771 3657 40 16 05/05/99 74 5.00 2.2% 3750 4100 3925 3780 3797 350 17 05/07/99 73 4.50 4.5% 4040 3710 3875 3786 3870 330 18 05/07/99 80 5.50 4.5% 3610 3710 3660 3779 3820 100 19 05/07/99 72 6.00 4.3% 3310 3400 3355 3757 3630 90 20 05/12/99 38 79 86 4.50 3.2% 4810 5110 4960 3817 3992 300 21 05/21/99 81 78 5.00 4.6% 3660 3830 3745 3813 4020 170 22 05/24/99 84 79 4.50 5.4% 4100 4470 4285 3835 4330 370 23 05/24/99 35 60 53 5.25 5.0% 4760 4590 4675 3871 4235 170 24 05/24/99 35 63 58 5.50 4.7% 4930 4360 4645 3904 4535 570 25 05/24/99 35 58 56 5.00 4.8% 4630 5180 4905 3944 4742 550 26 05/24/99 35 58 56 5.00 5.0% 4750 5380 5065 3987 4872 630 27 06/14/99 88 7.00 2.0% 4300 4380 4340 4000 4770 80 28 06/14/99 92 6.75 3.9% 4110 4260 4185 4006 4530 150 29 06/14/99 78 8.50 4.2% 4140 4000 4070 4009 4198 140 30 06/14/99 79 8.00 4.3% 4320 4280 4300 4018 4185 40 *** Averages *** 70 75 5.60 4.0% COMMENTARY OF STATISTICAL EVALUATION OF CONCRETE DESIGN RESULTS Mix Num: 8272 Strength: 3000 psi @ 28 Days Paragraph 5.5 of ACI 318-95 provides that as data becomes available during construction, the amount by which (F'cr) must exceed the specified value of (F'c) may be reduced, provided: (a) 30 or more test results are available and average of test results exceeds that required by Section 5.3.2.1, using a standard deviation calculated in accordance with Section 5.3.1.1, or (b) 15 to 29 test results are available and average of test results exceeds that required by Section 5.3.2.1, using a standard deviation calculated in accordance with Section 5.3.1.2. The required average compressive strength has been calculated using a standard deviation calculated in accordance with ACI 318-89 Section 5.3.1.1 or Section 5.3.1.2 and is the larger value of these calculations: F'cr = F'c + 1.34(SD) = 3000 + 1.34( 459.2) = 3615 F'cr = F'c + 2.33(SD) - 500 = 3000 + 2.33( 459.2) - 500 = 3570 SUMMARY OF STATISTICAL ANALYSIS 28 Day Test Data Number of Tests .......................... 30 Maximum Value ............................ 5065 psi Minimum Value ............................ 3355 psi Range .................................... 1710 psi Average Strength ......................... 4018 psi Standard Deviation ....................... 459 psi Required Average Strength to satisfy minimum probability conditions of ACI 318-89 Section 5.3.2.1 ............... 3615 psi Design excess beyond code requirements... 403 psi Temperature Test Plant (Fahrenheit) Placement Percent ......... 28 Day ........ Cumulative Moving Number Date Number Ambient Concrete Slump(in) of Air PSI 1 PSI 2 PSI Avg Average Avg of 3 Range i 02/18/99 70 4.50 5.1% 5320 5200 5260 5260 120 2 02/19/99 59 70 4.75 5.01 6120 6050 6085 5673 70 3 02/22/99 65 4.00 5.21 4810 4890 4850 5398 5398 80 4 02/22/99 48 62 6.75 5.3t 4720 4870 4795 5248 5243 150 5 02/22/99 31 38 56 5.25 4.9% 6070 6020 6045 5407 5230 50 6 02/23/99 68 3.75 5.0% 4670 4870 4770 5301 5203 200 7 02/24/99 18 71 63 4.75 N/A 4740 4820 4780 5226 5198 80 8 02/25/99 79 4.75 4.71 5270 5110 5190 5222 4913 160 9 02/25/99 40 70 72 4.25 N/A 4960 5110 5035 5201 5002 150 10 02/26/99 40 67 72 5.50 N/A 4180 4330 4255 5107 4827 150 11 02/26/99 40 70 78 5.00 M/A 5410 5230 5320 5126 4870 180 12 03/04/99 40 62 70 4.50 N/A 5920 5700 5810 5183 5128 220 13 03/05/99 42 6.00 N/A 4950 5000 4975 5167 5368 50 14 03/05/99 31 65 73 5.00 4.21 4910 5000 4955 5152 5247 90 15 03/05/99 31 68 75 5.25 3.9t 4590 4410 4500 5108 4810 180 16 03/05/99 31 72 79 4.75 4.5% 4760 4770 4765 5087 4740 10 17 03/05/99 31 63 71 5.00 3.8% 4770 4610 4690 5064 4652 160 18 03/10/99 43 60 66 6.00 4.51 4830 4760 4795 5049 4750 70 19 03/11/99 18 57 72 3.00 4.8l 4470 4640 4555 5023 4680 170 20 03/15/99 69 3.00 N/A 5960 6350 6155 5079 5168 390 21 03/16/99 65 68 3.50 3.81 4910 4740 4825 5067 5178 170 22 03/16/99 74 4.25 4.91 4780 4570 4675 5049 5218 210 23 03/26/99 40 65 70 5.00 N/A 4500 4770 4635 5031 4712 270 24 03/29/99 55 64 3.75 5.0% 5500 5420 5460 5049 4923 80 25 04/12/99 38 77 86 3.50 4.1% 4540 4640 4590 5031 4895 100 26 04/20/99 38 76 84 3.50 N/A 4690 4580 4635 5016 4895 110 27 04/23/99 40 89 84 4.00 N/A 5170 5210 5190 5022 4805 40 28 05/07/99 38 63 84 6.50 N/A 4060 4220 4140 4991 4655 160 29 05/12/99 38 79 86 4.50 3.2% 4810 5110 4960 4989 4763 300 30 05/24/99 85 89 4.00 3.8% 4770 4560 4665 4979 4588 210 *** Averages *** 66 73 4.61 4.5% COMMENTARY OF STATISTICAL EVALUATION OF CONCRETE DESIGN RESULTS Mix Num: 8274 Strength: 4000 psi @ 28 Days Paragraph 5.5 of ACI 318-95 provides that as data becomes available during construction, the amount by which (F'cr) must exceed the specified value of (F'c) may be reduced, provided: (a) 30 or more test results are available and average of test results exceeds that required by Section 5.3.2.1, using a standard deviation calculated in accordance with Section 5.3.1.1, or (b) 15 to 29 test results are available and average of test results exceeds that required by Section 5.3.2.1, using a standard deviation calculated in accordance with Section 5.3.1.2. The required average compressive strength has been calculated using a standard deviation calculated in accordance with ACI 318-89 Section 5.3.1.1 or Section 5.3.1.2 and is the larger value of these calculations: F'cr = F'c + 1.34(SD) = 4000 + 1.34( 508.2) = 4681 F'cr = F'c + 2.33(SD) - 500 = 4000 + 2.33( 508.2) - 500 = 4684 SUMMARY OF STATISTICAL ANALYSIS 28 Day Test Data Number of Tests .......................... 30 Maximum Value ............................ 6155 psi Minimum Value ............................ 4140 psi Range .................................... 2015 psi Average Strength ......................... 4979 psi Standard Deviation ....................... 508 psi Required Average Strength to satisfy minimum probability conditions of ACI 318-89 Section 5.3.2.1 ............... 4684 psi Design excess beyond code requirements... 295 psi ~e MIDLOTHIAN CEMENT PLANT · 245 Ward Road · Midlothian, Texas 76065 · www. txi.com SPECIFICATIONS Portland Cement Type fill (Low Alkali) A.S.T.M. O150-97 Bin Number Oar Number' Tons Date of Sampling July 1999 Monthly Average ASTM TEST SPECIFICATION RESULTS CHEMICAL REQUIREMENTS Silica Oxide, Minimum Percent 20.0 20.6 Alumina Oxide, Maximum Percent 6.0 4.2 Iron Oxide, Maximum Percent 6.0 3.8 M, agnesia Oxide, Maximum Percent 6.0 1.2 SO:] (63A less than 8%), Maximum Percent * 3.3 Loss on Ignition, Maximum Percent 3.0 0.9 ;nsoluble Residue. Maximum Percent 0.75 0.16 Tricalcium Aluminate, Maximum Percent 8.0 5.0 OPTIONAL CHEMICAL REQUIREMENTS Total Alkalies, Max. % (Na20 equiv.) I 0.60 0.41 PHYSICAL REQUIREMENTS Specific surface, Blaine Minimum (m2/kg) 280 345 Gillmore, Initial Set, Minimum (Minutes) 60 159 Gillmore, Initial Set, Maximum (Minutes) 600 282 Vicat, I Minimum (Minutes) 45 Initial Set I Maximum (Minutes) 375 94 Air Content, Volume, Maximum Percent 12 5 Autoclave Expansion, Maximum Percent 0.80 0.01 3 Day Minimum Compressive Strength, MPa (psi) 12.0 (1740) 21.4 (3097) 7 Day Minimum Compressive Strength, MPa (psi) 19.0 (2760) 29.9 (4338) STATE OF TEXAS ELLIS COUNTY J.R. Wendel , being duly sworn deposes and says: that he is Quality Sen/ices Manager of TXI Midlothian Cement Plant, who prepared the above report of tests and that the same is true and correct. Subscribed/C'~d sworn to before me this 11th day of August, 1999. / Oua~-C'Services Manager < L~,"~' "1 NOT?,P,Y PU!3LIC Concrete Products GRACE W.R. Grace & Co. 200t East Randol Mill, Suite · t t5 Arling;on. TX 760~ ~ (8{7) 46t-4t0t January 8, 1998 (~7) 459-~a84 Texas Industries, Inc. Dallas,.Texas Gentlemen: This is to certify that DARATARD-17, a water-reducing set-retarding admixture, supplied by the Construction Products Division, W.R. Grace & Co.-Conn., is formulated to comply with Specifications for Chemical Admixtures for Concrete, ASTM Designation: C-494, as a Type B & D admixture; and the Standard Specifications of the Texas Highway Department. No chlorides or halogens are added to DARATARD-17 as functional ingredients during manufacture. Material supplied for the above referenced project is identical in all respects, including concentration;-to' the one originally' submitted to'and'approved by ...... the State of Texas, Dept. of Transportation. The above is in addition to and not in substitution for our standard Conditions of Sale printed on the reverse side hereof. · Sincerely, Tom C. Henson District Manager Subscribed and sworn to, before me, this 8th day of January, 1998 A.D. ;? ~..~. .LO~ s..,:~. :; In and For the State o'f Texas We hope the information given here will 'oe helpful. It i$ tx~$ed on our best kno,~edge, and we believe it to be true and ~ccurate. Ple<3$e read all statements. recocnf,'nencJotlort.$ or s~g~;;;leslion$ herein in cc~j',Jc~o~ 'vCth o~f ¢o¢,dit~o~$ of Sa~e vah{c-h apCy to all Q(:x3d$ supc4ied ~y us. We sssurne no re$cx~sl~llty for ~ use of these st~ement~, reg. omrne~clot;o¢,$, or su~;;~estk::~$, r',~r do we Intend ~hem as a recommenda,~on fcr any use wh~c.h wo,-Id Infringe any patent or copynght. Grace Construction Products ~GE W.R. Grace & Co. - Corm 4323 Criles Stree~ P.O. Box 258.5-77252 Houston, TX 77003 December16,1998 Texas Industries, Inc. 1341 West Mockingbird Lane Dallas, Texas 75247 Gentlemen: This is to certify that WRDA with HYCOL, a water-reducing admixture, as manufactured and supplied by the Construction Products Division, W.R. Grace & Co.-Conn., is formulated to comply with Specifications for Chemical ... Admixtures for Concrete, . ASTM Designation: C-494, Type A (AASHTO M194, Type A). WP, DA with HYCOL does not contain calcium chloride or chloride containing compounds as a functional ingredient. Chloride ions may be present in trace amounts contributed from the domestic water supply used during the manufacturing process. The above is in addition to and not in substitution for our standard Conditions of Sale printed on the reverse side hereof. ,~ ncerely, Tom C. Henson District Manager Subscribed and sworn to, before me, this 16th day of December, 1998 A.D Lorene ~. Raso, Notary ~ublic In and For the State of Texas , ~.-~ LORENE B. RA$O ' J I' ('~l~).) MY COMMISSION EXPIRES ," ' ~'~_~,~/ March 28. 2002 ......... ~ ......... ~-- ~%~e hope t~.e [n~o~m3Lon s:ve~ ke~e w;i~ be h~p{~l. I~ is ~se~ cn ou~ [ecomme~dc'.ion5.or 5~es~ion5 he~ei~ in coniunclion wlt~ our con~ilions o[ 5c~e wkich cpply to o'.~ ~bods sup~l:ed by ~s. ~/e ~ssume ~o re5p~ns:b;~i~ ~o~ l~e u~e these 5:G~emenls. =ecomm. e~ciicns o~ su~e?;ons nor ~o w~ i~.t~ :~em c~ recommen~cl;o~ ~o~ ony use wk~c~ wou;~-in[rm~e Qny ~c;gnl o~ co~y';~l. ' Grace Construction Products ~GE 'vV R. Gr.ace & Co.. Corm 4323 Cr ~es S:,'ee' P.O. Box 2S8S.77252 Hous:on, TX 77003 August 18, 1998 Tey. ns Industries, Inc. Gentlemen: This is to certify that Daravair 1000, an air-entraining admixture, as manufactured and supplied by the Construction Products Division, W.P,. Grace & Co.-Conn., is formulated to comply with Specification for Air-Entraining Admixtures for Concrete, ASTM Designation: C260 (AASHTO M154). Daravair 1000 does not contain calcium chloride containing compounds as a functional ingredient. Chloride ions may be present in trace amounts contributed from the domestic water supply used during the manufacturing process. Material supplied for the above referenced project is identical in all respects, including concentration, to the one originally submitted to and approved by the State of Texas, Dept. of Transportation. The foregoing is in addition to and not in substitution for our standard Conditions · of Sales printed on the reverse side hereof. Sincerely, Tom C. Henson District Manager Subscribed and sworn to, before me, this 18th day of August 1998, A.D. ~',% LORENE B. RASO ,, Lorene B. Raso, Notary Public {t:.~%"):, ~' CO.'~.'~SS,ON EXP,~S- , In and for the State-of Texas L ~:~i~?~' March 28. 2.002 , '.','e ;-cae ';:e ,c~:rmc',on a.',-e'~_ ~'e:e ,,-, !~ be '"~'~:.._-~ ...~ h ,s =c;e;i c- c J, ~es~ ,,ec.../e:.~e 'a_nd .._,a be'.e-..e : 'cke t:ue ccd ccc,-;'='e..:':e :'e 'e''4 c;[ stSreme~:s. recDmmenCR'...-s.:.' su~.-'-es: c~'s he-ein .~- cc,' ~-c: c'~ w '- c~r cc"--',~.c"s oi sc~e .,J'.c- c...:c;., :: c'; gco:s s~ccl eC. by us. %*/e css.-e cc :e~cc~s:b,l:,f .:or the ,.se TEXAS INDUSTRIES QUALITY CONTROL DEPT. AGGREGATE SIEVE ANALYSIS Date: 07/17/99 Production Facility: TXI - BRIDGEPORT, TEXAS Size: 5.~7 Grading Designation: ASTM C-33 1" - Project: ..... ALL TESTS ..... Sample Location: SIEVE CUMULATIVE CUMULATIVE CUMULATIVE REQUIRED SPECIFICATION SIZE WT. RETAINED % RETAINED % PASSING % RETAINED % PASSING 2.0" 1.5" 0 100 0 100 1.0" 1.72 98.28 0 - 5 95 - 100 %" 17.46 82.54 %" 55,43 44,57 40 - 75 25 - 60 318" 79.30 20.70 C-d, 97.20 2.80 90 - 100 0 - 10 #8 98.83 1.17 95 - 100 0 - 5 ¢10 ¢16 #30 #40 #5O #100 #200 99.13 0,87 PAN WT. Decant .89% -i00% of tests: 151 .Size: 57 PLANT: BRIDGEPORT Job: ....... ALL JOBS ....... TEXAS INDUSTRIES QUALITY CONTROL DEPT. AGGREGATE SIEVE ANALYSIS Date: 04/11/99 Production Facility: INGRAM (GLEN ROSE) Size: 33 Grading Designation: ASTM C-33 FINE AGG. Project: ....*ALL TESTS* .... Sample Location: SIEVE CUMULATIVE CUMULATIVE CUMULATIVE REQUIRED SPECIFICATION SIZE WI'. RETAINED % RETAINED % PASSING % RETAINED % PASSING 2.0" 1.5" 1.0" =?4" ~" 3/8" ~N 1.82 98.18 0 - 5 95 - 100 #8 13.29 86.71 0 - 20 80 - 100 #10 #16 29.86 70.14 15 - 50 50 - 85 #30 44.70 55.30 40 - 75 25 - 60 ~0 #50 75.23 24.77 70 - 90 10 - 30 #100 92.82 7.18 90 - 98 2 - 10 #200 99.04 0.96 PAN VVT. 2.58 Fineness Modulus S.E. 91.00 100% of tests: 3 Size: 33 PLANT: INGRAM(GLEN ROSE) Job: ...... *ALL JOBS .......