Magnolia Village-LR010824 REPORT OF FIELD
, . COMPACTION TESTS
ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
972/620-8911 - 972/263-4937 (Metro)
FAX: 972/406-8023
TESTED FOR CONSTRUCTION MANAGEMENT GROUP DATE 08/24101
DALLAS, TEXAS
PROJECT MAGNOLIA RETAIL OUR REPORT NO. 01614-14A
COPPELL, TEXAS
TEST DATA:
TEST ~ ELEV. i SOIL ID ormuuM MAXIMUM I. AB IN PLACE IN PLACE PERCENT
NO. DATEDEPTH"~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY OENSITY COMPACTION COMMENT*
% PCF % PCF
21 08~24~01 FG 2 14.0 114 14.5 113 99 1 -A
22 08124101 FG 2 14.0 114 14.2 111 98 1-A
23 08/24101 FG 2 14.0 114 13.4 114 100 1-A
TEST LOCATION:
21 45' WEST AND 125' NORTH FROM SOUTHEAST CORNER OF BUILDING PAD
22 25' WEST AND 90' NORTH FROM SOUTHEAST CORNER OF BUILDING PAD
23 30' EAST AND 80" SOUTH FROM NORTHWEST CORNER OF BUILDING PAD
1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS~//
2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS ~
3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS ~'J j
Our test resutts & repolto are for the excluslve usa of the Client (and their designated recipients mi file in our office) and shall not be reproduced and/or dist~uted exc~ w ~express approva ALPHA. The use
of our name&test ~sults must receive our written approval. Test resu~ & reports apply only to the samples tested and/or obsarved, and are not Indicative of the qflitie~ of sPimH~ilarTsh;ecimens.
Geotechnical Engineering · Construction Materials Testing · Environmental Engineering · Consulting