Loading...
SW0001-CS010904Riverchase Sidewalk SW 00 -01 Cover Sheet 1. Need to add the names of the Mayor, City Council, City Manager and City Engineer. Sheet C 1.0 1. Label the graphic scale. 2. Label the ownership and width of the easements belonging to the City of Irving and Dallas Water Utilities. Label the width of the TP &L and DP &L easements. Label the City of Coppell's existing 15 -foot sanitary sewer easement that is shown on the plans. 3. Do Notes 5 & 6 of the GENERAL NOTES apply to this project? 4. It is Starleaf Street. Sheet C2.0 1. Would consider stationing the centerline of the sidewalk. 2. There is a 42 -inch water line in the DP &L easement. It needs to be shown and labeled. We do not have a set of plans for this water line. 3. The top of the 60 -inch storm sewer, as shown in the design plans, is at the same approximate elevation as the flow line of the proposed 5'x3' box. Is there room to construct the box culvert? The box will have to be extended when Star Leaf Road is constructed, need to take into consideration where and how the existing 39 -inch RCP will tie in. 4. Is there a standard for the 5'x3' box culvert in the NCTCOG or Coppell standards? 5. The Type B headwall detail in the Coppell standards is for a pipe culvert. Is this the standard that the plans refer to? 6. The 54 -inch water line is labeled as 30 -inch in the City of Irving easement. ��