Princeton P1-CS 970717CITY OF COPPELL PLANNING DEP~ ~TAFF REPORT PRINCETON pbRK_._ pIt IMINARY PLAT P & Z HEARING DATE: {uly 17, 1997 C.C. HEARING DATE: August 12, 1997 II)CATION: SIZE OF AREA: 1.6583 acres; 2 two story ~ ~ - 23,400 s.f. total CURRENT ZONING: TC (Town Cente~) APPLICANT: Applicant: 2425 E. SouthL__nke Blvd., #l.q0 Southlake, TX 76092 (817) 488-4200 3131 McKinney Ave., DMlas, TX 752~4 (817) HISTORY: No platting history. TRANSPORTATION: way. Town Cent~ Boulevald is nn sir. ess street with a variable right-of-way. SURROUNDING LAND USE & ZONING: North - South- Fast - West - vacant; "TC" Town Center vacant; "TC" Town ~ Fire Station No. 3 and ~ Justice Centre'; "TC" Town Cenm' H~ ~ subdivision; "PD SF-9" PlannM Deveiepment, Single Family-9 Item# 7 COMPREHENSIVE PLAN: DISCUSSION: approximately 12,000 square feet in size. As noted on the si2 plan this. will be a phased develolmm~ and it will be~/a wi~ the co~n of the north building. On the plan it is not clear if the entire pavement will be in place during the first phase of constructkm. The applicant needs to delineate phase lines on the site plan. for the loading and unloadt~ of merchandise and goods. Two buildings of this size require two londing spaces. This applicant is seeking a variance for a single loadin~ space. From staff perspective, the loading space shown on the site plan located at the northeast comer of the parking area adjacent to Town Center Boulevard is extremely hnpractical. It is unlikely to be used for that purpose because it is so far removed from the office stnum~es. A more logical location for a single loadin~ space would be in the center parking median between the two office buildings. Staff is well aware that the plan as drawn could not ~_od_n~- a loading space ia that particular location. Therefore, we suggest that the applicant either modify the site pha to include two loadin~ spa~s, one of each convenient to ench building, or seek a special exception from the Board of Adjustment to · 'hminate both loading spaces. As this is Town Center property the building elevations must be approved by the Coppell Town Center Architeimm~ Review Board, as well as the Commission and Council. Copies of the drawings were sent for Board's review. RECOMMENDATION TO THE PLANNING AND ZONING COMMISSION: Staff recommends approval of the prelimina~ plat and site plan subje~ to the following conditions betn~ met: 1) Delineate phase lines on site plan. 2) Redesign loadin~ space. 3) Board of Adjustment grant a special exception for loading 4) CoppeH Town Center Architectural Review Boasl approve build/ns elevations. Item # 7 ~) 6) 8) Eliminate sign mmaim~ along Denton Tap on Site Plan. AH pavement adjacent to Town Cent~ Boulevard must observe Lhe ALTERNATIVES: 1) P. ecomn~q~ approval of the p~.iminary plat and/or s~ plan 2) Reco~ dinpptoval of the ~ pint and/or ~ plan 3) Recommend modification of the pre~ plat and/or ~ plan 4) Recommend approval of I1~ ~ plat, but take ~ site ptan ATTACHMENTS: ~) ~eUmin~ mat 2) s~ Plan 3) t. andscape ?an 4) Irrigati°n Plan. 5) S~ Pln/~filifif~s Phn 6) De~nn~-n~ c~ Item# 7 ENGINEERING COMMENTS CON~ACT: ~ ~ ~,.~., ~ cay ~ O~'P~) I II I I I!1 I I I Ill I I Iii 1. Impact fees will be required.