Loading...
Princeton P2-LR000712 CONCRETE INSPECTION AND COMPRESSION TEST REPORT Client Alice Lee c/oRealty Capital Corp. Work Order Number: 00-2173 Project 00-014 Lam Lee Report Number: 00.014.232 SPECIFICATIONS PROJECT DATA iStrangth (psi): 3000 iDate of Placement: 7112/00 iSlump(in.): !4, - 6 ISampied by: ~Contractor made Air Content(%): nNaot to exceed Weather. !Sunny/warm IConcrate Temp(F): ' 100 Supplier/Mix: Pioneer FIELD DATA SET # 1 Ticket #: i I tTime Sampled: Slump (in.): I ! 1Unit Weight (pcf): Concrete Temp(F): ~-~-~e: tTIme Batched: Contractor ~ir Content: ~r T emp (F): made cylinders, no location given Location/Remarks: SET CYLINDER DATE NO. NO. TESTED i 1 I 7/19/00 I 2 8/9/00 1; 3 8/9/00 I I i 4 AGE MAX LOAD STRENGTH TEST CYLINDER RESULT (days) (lbs) (psi) SOURCE 7 89000 I 3150 I 28 I 119000 4210 28 i 114000 ! 4030 Discard I I i NOTES NORMAL CYLINDER SIZE: 5X12, AREA:28.27.q. in. UNLESS NOTED HERE: TYPE "A" CONE FRACTURE UNLESS INDICATED OTHERWISE IN NOTES. TEST RESULTS COMPLY WITH PROJECT SPECIFICATIONS UNLESS INDICATED "NON-COMPLIANCE" IN NOTES. FIELD TESTS BY SOILTECH ENGINEERING AND TESTING, INC. ARE PER APPLICABLE ASTM STANDARDS: C138, C143, C172, C231. CYt. INDERS MOLDED AND CURED BY SOILTECH ENGINEERING AND TESTING, INC. ARE PER ASTM C31, TESTED PER ASTM j CH.: NGfNI RING AND TESTING, INC. ames M. Perdue eneral Manager 2502 Gravel Drive · Fort Worth, Texas 76118 · 817.595 0064 telephone · 817.589.7279 metro · 817.595.0708 fax