Princeton P2-LR000509PROCTOR REPORT Realty Capital Corporation 920 S. Main, Suite 170 Grapevine, Texas 76051 Project Project Date Project No Report No Report Date Proctor P/U Date: Sample Location: Intended Use: Princeton Park Phil-Office Bldg 5/9/0O 00-092 00.092.102 5/19/00 Material Description: Method of Test: Standard x PI Requirement: Run Remarks and other special instructions: 5/9/00 Stockpile (On Site) General Fill Dark Brown Sandy Clay Modified Other -Soiltech ENGINEERING & TESTING, INC. Material Description: Optimum Dry Density: Optimum Moisture Content: Moisture/Density Relationship of Soil Dark Brown Sandy Clay 101.2 21.8 Liquid Limit: 54 Plastic Limit: 20 Plasticity Index: 34 SOILT~CI-[ ENGINEERING/~ND TESTING, INC. James M. Perdue General Manager 2502 Gravel Ddve · Fort Worth, Texas 76118 · 817.595.0064 telephone · 817.589.7279 metro · 817.595.0708 fax PROCTOR REPORT Realty Capital Corporation 920 S. Main, Suite 170 Grapevine, Texas 76051 Project Project Date Project No Report No Report Date Proctor P/U Date: Sample Location: Intended Use: Material Description: Method of Test: Standard x PI Requirement: Run Remarks and other special instructions: Princeton Park Phil-Office Bldg 5/9/00 00-092 00-092.102 5/19/00 519100 Stockpile (On Site) General Fill Dark Brown Sandy Clay Modified Other -Sofltech ENGINEERING & TESTING, INC. Material Description: Optimum Dry Density: Optimum Moisture Content: Moisture/Density Relationship of Soil Dark Brown Sandy Clay 101.2 21.8 Liquid Limit: 54 Plastic Limit: 20 Plasticity Index: 34 SOILT~CH ENGINEERIN~ND TESTING, INC. James M. Perdue General Manager 2502 Gravel Drive · Fort Worth, Texas 7'6118 · 817.595.0064 telephone · 817'.589.7279 metro · 817.595.0708 fax PROCTOR REPORT Realty Capital Corporation 920 S. Main, Suite 170 Grapevine, Texas 76051 Project Project Date Project No Report No Report Date Proctor P/U Date: Sample Location: Intended Use: Princeton Park Phil-Office Bldg 5/9/O0 00-092 00-092.101 5/19/00 5~9~00 Stockpile Select Fill Material Description: Reddish Brown Sandy Clay with some rock Method of Test: Standard x Modified PI Requirement: Run Remarks and other special instructions: Other ' Soiltech ENGINEERING & TESTING, INC. Moisture/Density Relationship of Soil Material Description: Reddish Brown Sandy Clay w/rock Optimum Dry Density: 128.7 Optimum Moisture Content: 10.5 Liquid Limit: 26 Plastic Limit: 16 Plasticity Index: 10 SOILTECH ENGINEERING AND TESTING, INC. In e ral Manager 2502 Gravel Drive · Fort Worth, Texas 76118 · 817.595.0064 telephone · 817.589.7279 metro · 817.595.0708 fax