Loading...
Riverchase(6.3)-CS 941027DEVELOPMENT VIEW COMMITTEE ENGINEE NG COMMENTS ITEM: DRC DATE: October 27, 1994 and November il, 1994 CONTACT: Ken ~, P.E., Assistant City Manager/~ Engineer (393-1016) COMMENT STA~S: .. .-~-~.'*rm ' · ~PRELIMINARY i ~ Preliminary Plat Comments: 1. Any improvements within the TRA easement will require prior approval from TRA. 2. A drainage easement on the southern part of the property should be provided that includes all the drainage system. 3. The 30 foot common access easement along the north side of the site should also be a fire lane. Site Plan Comments: 1. You should reevaluate the location of the southern most drive approach into the facility. 2. The sign should be relocated outside of the existing easement on the south side of the site. 3. The fire lane adjacent to the north side of the site should be constructed. 4. The meter should include double check valves. 5. The easement along the southern side of the property should be labeled. I ancLqcape Plan Comments: 1. You should reevaluate the location of the Bald Cyprus tree at your north exit to allow for greater visibility out of the site. Irrigation Plan Comments: 1. You should reevaluate the current layout of your irrigation system on the south side of the site. The majority of this system is located within various easements and if those easements ever need to be accessed more than seven irrigation lines would be damaged. 2. The double check valve for your irrigation system should be located in the right-of-way of Riverchase Drive not on-site.