Riverchase (6.1)-CS 940316 (2)Centrel ...gionel Westeweter System 3110.620.010 March 16, 1994 Mr. Steve Goram Director of Public Works City of Coppell Coppell Interceptor, Sta 15~91 -' '~ . r In response to the point of entry request dated March 14, 19;4, theAJthority has reviewed the construction standards to be utilized for the point of entry. The Authority approves your request based upon the information submitted, which l)~ includes the construction plans dated March 4, 1994, for Riverchase Plaza, Phase I, as designed by Winkelmann & Associates, Inc., for the City of Coppell, Texas, but is subject to the following requirements: The Central Regional Wastewater System Engineering Field Services Division must be contacted at (214) 263-2251 at least 72 hours prior to construction. If the Authority is not notified, the Authority reserves the right to request the contractor to excavate his work for inspection. All inspections shall be performed by Authority personnel only. City inspectors are not responsible for Trinity River Authority facilities. All points of entry must be constructed within one year after their approval by the Authority. Any alterations to the plans concerning the Authority's facilities must be pre-approved by the Authority. 3~ A preconstruction meeting between the contractor, the City of Coppell and the Authority will be required prior to construction. P.O. Box 531196 Grand Prairie, Texas 75053 Metro (214) 263-2251 Fax: (214) 264-1382 Fax: (214) 262-0619 March 16, 1994 MR. STEVE GORAM Point of Entry Request Page Two e All PVC connections shall use an A.C. coupling with O-ring gaskets and use the core drill method of entry only. The 8-inch PVC connection shall be concrete encased 3.0 feet from the manhole. 5. Wastewater service for Riverchase Plaza, Phase I, shall not commence until the Authority inspects and accepts the point of entry. 6. A standard TRA manhole shall be constructed at the proposed point of connection, per Sheet 8 of 22 of the construction plans. The proposed 8-inch PVC connection and manhole shall be constructed in conjunction with a Permit for Riverchase Plaza, Phase I, currently being processed. This point of entry shall be metered at Meter Station 17.0E. If you have any questions, please contact Robert J. Roth, Technical Services Engineer, at (214) 263-2251, extension 202. Manager, Technical Services PMC/dg cc: Robert J. Roth, Technical Services Engineer, CRWS Eugene Middleton, P.E., Winkelmann & Associates, Inc.