Loading...
SW0101-LR010509 Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS JOB NO.: CLIENT: Quantum Contracting, Inc. DATE: 9 May 2001 PROJECT: 20___01 Coppell Sidewalk Repair SUPPLIER: Hanson LOCATION OF POUR SET 1: Sidewalk in front of 312 Morning Mist, 15' long north to south, 12' long east to west leading up to house LOCATION OF POUR SET 2: SAMPLE DATA: SET 1 SET2 MIX NO. 9339 Truck No. 1883 Cement Ticket No. 818433 Flyash Time Batched 1:40pm Sand Time Sampled 2:20pm in. Concrete Temp. (ASTM C1064) 84°F 1.0 in. Air Content (ASTM C231) Water Unit Weight (ASTM C138) Admix #1 Admix #2 AEA COMPRESSIVE STRENGTH TESTS (ASTM C39) (Standard 6 inch x 12 inch cylinder) Cylinder Slump Age Test Total Load Compressive Required Number Inches Days Date Pounds Strength 28-Day (ASTM C143l psi Strength 26 5.00 ~...~7'-'"'~5/16/01 95,900 f 3:390 27 5.00 f 28 ~B/06/01 112,800 ~' 3990 28 5.00 [ , 28 _,~,~6/06/01 116,100 ~ 4110 28-Day Averag~ 3000 TECHNICIAN: EWM (1:30pm-3:30pm) ~ DISTRIBUTION: (1) Quantum Contracting, Inc. (1) City of Coppell 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148