Loading...
Sandy Lk Cross L3-CS 890420 ,! ,: ~. . Date: April 20, 19 ~'~'~ ' ~ ', " ../ ' · '. ~ / ' ~ ....... ~ ~ . ~,~ ~,. ~ t.,{ / RE: Case ~S-1042 LOCATION South of Sandy Lake Road on Denton T~p, next to the existin~ McDonald's restaurant. REQUEST: Zoning change from (R) Retail, to (C-SUP) Commercial Special Use Permit, for the operation of a Kentucky Fried Chicken restaurant ~,p_) ~[,,~ APPLICANT: Kentucky Fried Chicken. ] · '.._~.~ .~ [ ~,v' :' '~,-'-"" ~ j U '" SURROUNDING LAND USE & ZONING:k~ ~! ;~: .- (See Zoning ~ap) ~ ',- /~ .(i)..~"' ~ .(.;.-. SUMMARY: Staff has ~o--obj~qtions to the Special Use Permit in general~howev~,) staff does not support the request of an additiona/---d~-i~fe-way, since it does not meet the Sub~io~-.~Or~_~nance requirements,. Also, staff recommends th~onument sign~ .deleted from the SUP request, and ALTERNATIVES: 1) Approve with variance requested. 2) Approve without variance requested 3 ) Deny ATTACHMENTS: 1. Location map 2. Zoning exhibit 3. Letter from Ginn, Inc., dated April 13, 1989 S1042STF ~ '~/... ~_j'" ' '"' / b <. GINN, INC. CONSUI,TING ENGINEERS April 13, 1989 ~ Mr. Russ oyle, P.E. City of yoppell i~~ I ~ 1989.' ~'~ P.O. Bg~ 478 · . Coppel~, TX 75019 ~_~_. . .... Re: Kentucky Fried Chicken ............. Zoning Request and Final Plat/Construction Plans DRC-Engineering Dear Mr. Doyle: We have reviewed the above referenced project and offer the following comments. Regarding the Zoning Change Request from Retail to Commercial- Special Use Permit with Drive-Thru, we suggest the monument sign not be indicated on the Site Plan at this time under the SUP but rather be handled as a separate issue. Also, a Variance Request should be added on the Site Plan for a north-drive access to be allowed off of Denton Tap Road. These Site Plan revisions can be made conditions of any motion when considering this issue at the Planning & Zoning meeting with the revisions being requested to be made prior to the Zoning Change Request going forward to City Council. Regarding the Final Plat we have the following comments. 1. Applicant should re-verify the square footage and acreage calculated for this site. 2. Per the City's Comprehensive Floodplain Management Ordinance, paragraph 4 oii page 34, a Floodplain Permit note needs to be added to the plat. This site, however, is not within the limits of any existing floodplain or floodway, therefore, a permit number for development would not be applicable. 3. Any proposed fire lanes outside the limits of the platted site need to be dedicated by separate dedication instruments. These instruments should be executed, notarized and provided to the City prior to the Final Plat being submitted to the City Council for consideration. 4. The floodplain note shown on the Final Plat is not required to be on the plat, and thus, can be deleted. 17103 Preston Road · Suite 100 · LB 118 · Dallas. Texas 75248 · Phone 214/248-4900 5. The need for the Variance Request for a north-drive is due to the Sub-Division Ordinance requiring, for a 35 mph roadway, 100 feet be provided between drives and for a 40 mph roadway 120 feet be provided. Approval of the variance would allow a driveway spacing of only 72 feet approximately. Circulation will still exist without this drive via the common access drive between McDonalds and this site. Please reference the attached excerpts from the Sub- Division Ordinance. Regarding the Construction Plans we offer the following comments. 1. Power feed from TU Electric should be an underground feed from Denton Tap. 2. Site should sewer (sanitary) from tke rear as per the original Preliminary Engineering plan. This will alleviate the need for the applicant to open cut approximately 65 feet across the new Denton Tap Road pavement (3 southbound lanes, median and 1 northbound lane). Public safety and reduced liability will be better assured for both the applicant and the City with this requested revision. 3. The 2" domestic water tap should be in the same trench as the fire hydrant lead tap if the new Denton Tap Road concrete pavement is existing at the time the site develops. This will alleviate the need for 2 street cuts or tunnels (whichever is required by Public Works) and only require 1. 4. All pavement shall be required to be 6" thick, 3000 psi at 28 days with a 6" lime stabilized subgrade (6%). This includes any drives. Also, no cushion sand is allowed between the subgrade and the pavement. 5. Applicant must submit written permission from the property owner prior to the City allowing any pavement to be placed outside either the platted area or outside any fire lane easement boundaries. This shall be required prior to approv~l Cf tile construction plans. Please call if you have any questions. Sincer~e~ly, /-') Kevin Peiffer,/~. E. ;/ KP/dsp cc: Robert Howman, Ayres Assoc. DRC File 89305 DRIVEWAY RADIUS All driveways intersecting dedicated streets shall be built with a circular curb radius connecting the six-inch raised curb of the roadway to the design width pavement of the dmiveway. Driveways shall be located far enough from the interior property line to permit the curb radius to fall entirely in f~ont of the sub)eot property. The City Engineer shall approve the driveway w~dths and driveway radius at the time of site plan review previous to issuance of any butldtng permit. In order that the definition of the location of the edge of pavement for the thoroughfare may be maintained, driveway radii shal! always be designed to become tangent to the street curb line. Two-way driveways sha]l always be designed to intersect the street at o gO-degree angle. One-way driveways may be designed to intersect o street at o minimum 4S-degree angle. DRIVEWAY SPACING AND LOCATION The spacing and location of driveways shall be related to ad)acent driveways and nearby street intersections. The spacing between driveways shall be dependent upon the speed limit of the thoroughfare and ore recommended os follows: Isee Figure 2) 20 ~5 25 65 35 100 ~0 120 ~5 150 50 200 Appendix A H~n~mum spacing 5ha~! not be mo~e than ten feet ]ess than the ~ecomme~ded spacings shown above. Spacings between d~tveways wtl! be measured along the p~ope~ty )the f~om the edge of one d~tveway to the ¢)osest edge of the next driveway and not f=om cente=Itne to cente=Iine. At inte=sections with no f=ee =ight-tu~n ]one, the minimum d~stonce A, F~gu=e 2, of o d=ive- way f~om the ~nte=section of mo~o~ tho=oughfa=es shal] be ftfty feet and the minimum distance A, Ftgu=e 2, of a d=~veway f=om the ~ntezsectton of mina= tho=oughfo=es shall be tht=ty feet. General =equt=ements fo= way design o=e shown in Ftgu=e 2. A summary of d~veway wtdth, and angle ~equi~ements ts given in Table ]]. TABLE ]! SUt4NARY OF REQUIREMENTS RESIDENT]AL CO~ERCIAL I~[XJSTR]AL WIDTH (WI Minimum 12 20 Maximum 24 30 40 RIGH] TURN RADIUS Minimum S l0 1S Maximum 15 20 25 ONE-WAY DRIVE ANGLE Minimum ~degreesl 45 4S MISCELLANEOUS THOROUGHFARE STANDARDS A. Specific detofis shall be as shown in the Design Standards fo= the City of Coppeli. Appendix LEGEND - DIslance b~x:k from irder~echon - Drwewoy rodlu$ W- Approoch width D- D~tonce ~tw~ driv~wo~ 50' Mm~mun II FIGURE 2 - GEOMETRIC FOR DRIVEWAY DESIGN PAR'ONG R£~'tREI,~E.~;TS LANDSCAPE AREAS g I i ~' I (pRoPOSED SHOPPhYG CENTE~) :~.,.~ . ~, ............. ~ ..... ~ ............................ ~ ~'~ s c~'c~' { LEGAL DESCRIPTIO.%' ~,~; Os . .......................... ,., - ' ........................... ~. ~ ,. ~ ~ .... ~ ~ r.- i~ ~ ~ ' - .................................................... ' ' ~ ~ '"' ~i ;~_'.:~., · : r~ ............................ ' ~ · '/ ~ I. I ~ ~ ~2.~ ~ I~ , i i .... ~ ....... _~--- '""'' '~ ~'"~ ~'' ' ~ '(~ __1 ", ....~~.~~t?~:-~-~-~ ..................... - ~ , i ............ · ...... .-~ ~. _ ........ ;-; ....;-~ ............ ~ ,,, ~ _ , · --~ ~:; -~- ' .... ' ........... , ' ~ ' ,'~ ' ~0'~ ...... - .... ~-'~ ~"~";.'~L' --' ~ ' ' '' -~-~--~- ' .... ~"-- '1 ...................... ~ ' ' ~ " ........... ~ -~--;" J ~-J--- -~, ; i ~,~.~ i,' I i I ~. ---- ~ ........... ~ ...... · ~--t-.--' .... ' - ~'"' ' ~ , ~ ' · = -~ · ,.,n,,-~- '" ~.~,., "~,~.,~' ,~'M'" ~,','~:,'' '" . taD' ': "' ~' ~ 0~9'05' [ -- '~-T ~ 155.70 .... ~~:;s ~?~; ,~' L ~_ u [ ~e ~: I~ ~l ~: b ...... ' ..... ~ ~ ~ / s o2~ ~ [ ~ ~- ~''t' ~ _~ ................... ~ [~-~c ,' -,~, ~'~ .... ' ~ ' ' ~, ~--:: ' / [~S~GB'W*~L~ 'AREA UNDER CONSTRUCTION ' , ~ ~ D ~ H T 0 H T A P R 0 ~ D~t 2 O' R · ) 1~ =....,......~::_._,,._ ................ ..,.'"* ...,-- ~ ~ - ~,-~"- ~;:.~, :.~,J:','~,."T..I'.'. .... = '"" ';~":: VARIANCE REQUESTED , · I. NO~TH Ot/-S/T[ XPPRO,4C~ BE' ALLOV,~,. -'-:7' ' ~." ,~. '":,,"~'--".=,L~,#:~.,~,':,=~- ' H. T. ARDINGER, JR. .... -- ...... .:'; .'~ ,'::'.:' ~':|',.T' · - (PROPOSED SHOPPING CENTER) . . . . i . .... -., -- ~-T;~-'~'.' ,I ' i ..... ' ..... ; t r ................................. · x,x., - ' .............. ',~,'-.~.,; · ._.Ts~-..:..-..,~, ,: , ',. ..... - ............. 'l .... : .... '. ,s it: ~.I *.~o*, ~c~rs h:' : % - : ~!; ;: (so.,. sou~ r~) !t *., ;i ,'- !; ', II} "~,. :! . .. I ': : I ~ ,. ¥: ... ~-~ ...... ~'_ ....... r ~_,,,.' ................. ~q.,- ........... ~ ...... .~__.- ~. ~ . . ~__~_~_~._.~-~ ................ ~,, ---?-~- ,.---- ............................ =.___ ........ .,.,,. _ ......................... ......... s o~.'- [ ,:"- ':.|:'|:'.=:?.% ,':'.":, :',.':.~.~'.'=' 2" ,--..~, - ~' i " ' ~' D E N'T 0 N T& P R 0 · D ( ! 2 O' R. O. W. ) __ ,......,, ..--- ................ , ' ~" FINAL P~T - '~ -~--'~-.=.;-~-c:~,~'-'-x-'~,-T:,.."- .~';' SANDY I~%KE CROSSING ADDITION ~ "~ ~--"' '* i°a'~' I ' PROPOSED ZON!NG I$ CCId~ERCIAL $.U P ~ ~ eom~. ~ co~M~ Sheet