Sandy Lk Cross L3-CS 890327 GINN, INC. CONSULTING ENGINEERS  / :~! -.= city zngineer \ City of Coppell P.O. Box 478 ' Coppell, Texas 75019 Re: Restricted Left Turn Access to Sandy Lake Crossing from Denton Tap Road. Dear Mr. Doyle: We have reviewed the attached request and sketch for a proposed left turn access to the subject property as requested. Basically the left turn access proposed is prohibited in the Subdivision Ordinanc~ and the Streetscape Plan. The Subdivision Ordinance requires 420 feet between median openings, measured from nose to nose, including 100 feet of full width median for landscaping. The proposed left turn access occurs in an area of the median 663.6 feet in length between median openings. If constructed as shown, the distance between median openings would be less than 420 feet. The Streetscape Plan requires at least 100 feet of full width median between openings for landscaping purposes also. This request would eliminate all of the aforementioned median landscaping between the Braewood Drive intersection on the south, and the median opening and left turn lanes serving both sides of Denton Tap Road at Minyard's main entrance on the north. If the person making the request insists upon pursuing this matter they must apply for variances to both the Subdivision Ordinance and the Streetscape Plan as a part of their platting efforts for the property. During that process they must show just cause why their request has merit in light of the facts that the property is: currently in a predominately undeveloped condition; bounded on the east by Denton Tap Road, and the north by Sandy lake Road with access to both; and is already proposed to be served, along with developed property on the east side of Denton Road, with two median openings and left turn lanes along its Denton Tap Road frontage. If a request for the abovementioned variances is considered, it must contain the provision that the property owner making the request enter into a commitment with the City of Coppell to provide funding sufficient to offset the City of Coppell's costs of Engineering, Testing and Inspection, and Construction prior to construction of the requested restricted left turn access. 17103 Preston Road · Suite 100 · LB II8 · Dallas. Texas 75248 · Phone 214/248-4900 If the variances are approved by the City Council we will be happy to prepare a Change Order to the Denton Tap Road Improvements Project. Please feel free to call me if you have further questions. Sincerely, ~----)j" ~ > ~ / 'J~h'~ C. Karlsruher, P.E. Project Engineer enclosures cc: H. Wayne Ginn, P.E. Kevin E. Peiffer, P.E. File J-378 (a:ardltl)