Sandy Lk Cross L3-CS 870506DRC 050687 Page 9 PETITIONER: Howard Herrington - Howard Properties 2838 Woodside Drive Dallas, Texas 75Z04 1st Review of Sandy Lake Crossin~ - Preliminary Plat ENGINEERING: 1) Please submit water and sewer plan (Preliminary). Show the existing culvert on the N.W. corner of the property. According to p & p Engineering, the size of the existing storm sewers are 36" not 48" RCP. 3) Please coordinate with Connell/Skaggs Addition for Drainage Improvements, in the N.W. corner. 4) Fire lane width is 24' min. Please check with Fire Dept. for Z0' fire lanes. 5) Provide Hydraulic calculation chart at the time of final platting. 6) Provide legal description of the site on the preliminary plat. BUILDING IN SPECTION: 1) Need 3 30' X 1Z' loading spaces for Albertsons. Need 1 30' X 1Z' loading space for space marked Anchor. 3) Need Z 30' X 1Z' loading spaces for Retail one space. 4) Need 1 30' X 1Z' loading space for Retail two space. FIRE DEPARTMENT: 1) Fire hydrants required every 300 feet. Z) Fire hydrants and water system must be operational before construction begins. 3) The access roadway shall be extended to within 150 feet of all portions of the exterior walls of the first story of any building. 4) Uniform Fire Code, 1985 is applicable. 5) Refer to Chief Mayfield's comments. D. LONE STAR GAS: 1) No Comments. GENERAL TELEPHONE: 1) No problems - will need to discuss facilities to serve each building - will need conduit to serve each location. PARAGON CABLE: 1) Cable is not available unless easement granted. U.S. POSTAL SERVICE: 1) No Comments. DEVELOPMENT INSPECTIONS: 1) Will need Soils Report to determine if sub-grade will require Lime Stabilization. Z) Use of cushion sand under paved surfaces is not allowed. 3) Prior to beginning construction - a Pre-Constrnction Conference must be scheduled with the Chief of Land Development. (Contact Steve Morton at 46Z-00ZZ). 4) Approaches too close to each other and intersection. DRC 050687 Page 10 5) Utility Lay Outs. 6) Irrigation Plan. 7) Street maintenance (Cut - Bore). 8) Street assessment. 9) Letter of Agreement. TEXAS POWER AND LIGHT: 1) Preliminary Plat is acceptable. Z) Easements will be required along perimeter of property. 3) Customer will be responsible for relocation of T P & L facilities. 4) Customer will be responsible for difference in cost between overhead and underground facilities and easements required for facilities. (DUCT BANK MAY BE REQUIRED). 5) Contact Tim Brancheau at 3Z3-8910. 6) Contact Bobby Northcut with T P & L concerning the Transmission Line Relocation at 7Z1-6Z00. PUBLIC WORKS: 1) Unable to obtain comments from Public Works Department. Please contact Steve Goram at 46Z-00ZZ. PLANNING AND DEVELOPMENT: 1) Revisions must be submitted by 3:00 p.m., on Monday, May 11, 1987 to be eligible for May Z1, 1987 Planning and Zoning action. Z) Please submit ZZ sets of folded plans in order to be reviewed by Planning and Zoning and City Council. 3) Show existing zoning on surrounding properties. 4) Show owners certificate. 5) Signature block for Mayor, City Secretary and Planning and Zoning Chairman. 6) Provide dimensions on all lots. FILE , SCH , Sandy Lake C~ossJn8 Maste~ ~. COPIES ~0: PRO.CT NO.: 8634 X FILE OTHERS: DATE: May 6, 1987 Horace T. Ardinge~ Buddy Lamberth P~TI C I P~TS REPRE SENT ING: S t e ye C 1 a u s s e n Stephen C. Hundley - SCH Architects Howard Herrington - Howard Properties Jim Kurtz - PAWA ~ Winkleman Development Review Committee - City of Coppell Chairperson - Taryon Bowman RE: Staff review of Preliminary Plat and conceptual site plar~ DISCUSSIONS ~D CONCLUSIONS Howard Herrington opened the meeting with a brief summary of events leading to today's meeting. Items covered included cu,- rent status with the anchor, Albertsons, and efforts to secure two or more junior anchors including possibly a health club. Taryon opened the meeting to comments from staff: General Telephone had no comments or problems. Tim Bradshaw of TP~L indicated that the major feeder lines woul.l need to circumvent the perimeter of the site to provide access the out parcels. Service will be overhead. Dale Jackso'~ reminded Mr. Bradshaw that the city has an ordinance tha~ requires all new service to be underground. Mr. Bradshaw indi- cated that TP~L installs only overhead unless the developer want~ to bear the difference in cost for underground. Mr. Jackson sail that he would follow up to confirm that the ordinance was cot'- rect. Fire: Requires a fire hydrant every 500' - ordinance require; 24' firelanes - however, Mr. Kurtz indicated that in previou~ discussions with the Fire Chief that 20' was adequate if building was sprinklered. SCH ARCHITECTS. IN(: 311 MARKET ST. SUIfl- 10~ DALLAS, 'TEXAS 75202 l fLEPHONE 214 744 342b Page Two Ginn Engineering Gabe Favre: Observed that the Plat will require a complete survey description. Also, they did not receive copies of the water and sanitary sewer plan. Jim Kurtz indicated that the plans had been submitted but that he would send additional copies. In addition, Mr. Favre observed that the left turn only condition along Main was unacceptable. Mr. Kurtz reminded him that in a previous meeting with Mr. Ginn, he had in- dicated that the condition was acceptable. Mr. Favre will take the matter up with bir. ginn. Howard reminded staff that both the Owner of this tract and the Connell shopping center has expressed a willingness to bear the cost for expansion of Sandy Lake which should be taken into consideration. Also, bfr. Favre requested that 50' and $0' radii be shown on the plans at all bends in th~ firelanes. Shohre Daneshuand asked that drainage improvements be coordinated with the City - also, the culverts shown are actually 56", nct 48". Mr. Kurtz observed that they are undersized in any event. Steve Martin indicated that before development, the city would require a traffic flow analysis dealing with access to the site. Dale Jackson offered the observations: On the plans show truck loading spaces as follows: 3 - 30' x 12' spaces for the main anchor 2 - for Retail 1 1 for Retail 2 1 for the Junior Anchor Taryon Bowman requested that all existing zoning surrounding the site be shown on the plans. Revised submittals must be in by 3:00 on Monday of the followir:g week. END OF CONVERSATION. If you have any questions concerning this memo, please contact our office as soon as possible. This repo~'t is assumed to be a true and accurate account of the conversation unless written notification is received within ten days of this meeting. Submitted by: